{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T09:11:14Z","timestamp":1766049074422},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>The aim of this study was to determine the average effective radiation dose and feasibility of ultralow dose dynamic expiratory computed tomography (CT) for evaluation of tracheomalacia (ULD) and to evaluate factors that impact image quality.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This is a retrospective study of 64 consecutive patients from September to October 2016 for the evaluation of tracheomalacia. All studies were performed with routine inspiration chest CT followed by ULD z(kilovoltage peak (kVp) 80, 100, or 120 and fixed milliamperage 10) or typical dose CT (TD) (kVp 100 or 120 with automated milliamperage) dynamic expiration CT. Image quality was considered diagnostic if the trachea area could be accurately measured for tracheomalacia assessment, and diagnostic studies were graded fair, good, or excellent. Scan length, image quality, and effective radiation dose were compared for ULD versus TD and ULD at 100 kVp versus ULD at 80 kVp. For ULD studies, patient factors were compared across image quality.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The ULD had a mean effective radiation dose of 0.08 mSv, with all studies of diagnostic image quality. The ULD showed 95% reduction in effective radiation dose (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001), 14% significant reduction in scan length (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.029), and qualitatively decreased image quality compared w2 ith TD (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). The ULD at 100 kVp had significantly better image quality compared with ULD at 80 kVp (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.041) with higher effective radiation dose (0.09 vs 0.05 mSv) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). Body mass index significantly impacted image quality for all ULD studies but not for ULD at 80 or 100 kVp.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>For evaluation of tracheomalacia, ULD showed low effective radiation dose less than 0.1 mSv and maintained diagnostic image quality.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000000806","type":"journal-article","created":{"date-parts":[[2018,12,7]],"date-time":"2018-12-07T19:58:08Z","timestamp":1544212688000},"page":"307-311","source":"Crossref","is-referenced-by-count":12,"title":["Ultralow Dose Dynamic Expiratory Computed Tomography for Evaluation of Tracheomalacia"],"prefix":"10.1097","volume":"43","author":[{"given":"Stuart L.","family":"Cohen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eran","family":"Ben-Levi","sequence":"additional","affiliation":[{"name":"Department of Radiology, Donald and Barbara Zucker School of Medicine at Hofstra\/Northwell, Hempstead;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason B.","family":"Karp","sequence":"additional","affiliation":[{"name":"Northwell Health Pulmonary Disease, Critical Care Medicine, Internal Medicine, Donald and Barbara Zucker School of Medicine at Hofstra\/Northwell; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard S.","family":"Lazzaro","sequence":"additional","affiliation":[{"name":"Northwell Health Thoracic Surgery, Donald and Barbara Zucker School of Medicine at Hofstra\/Northwell, Hempstead, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amar","family":"Shah","sequence":"additional","affiliation":[{"name":"Department of Radiology, Donald and Barbara Zucker School of Medicine at Hofstra\/Northwell, Hempstead;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Navid","family":"Rahmani","sequence":"additional","affiliation":[{"name":"Department of Radiology, Donald and Barbara Zucker School of Medicine at Hofstra\/Northwell, Hempstead;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rakesh D.","family":"Shah","sequence":"additional","affiliation":[{"name":"Department of Radiology, Donald and Barbara Zucker School of Medicine at Hofstra\/Northwell, Hempstead;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20230927","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1378\/chest.127.3.984","article-title":"Tracheomalacia and tracheobronchomalacia in children and adults: an in-depth review","volume":"127","year":"2005","journal-title":"Chest"},{"key":"bib2-20230927","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1111\/j.1440-1843.2006.00862.x","article-title":"Tracheobronchomalacia and excessive dynamic airway collapse","volume":"11","year":"2006","journal-title":"Respirology"},{"key":"bib3-20230927","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1001\/jama.2015.19431","article-title":"Association between expiratory central airway collapse and respiratory outcomes among smokers","volume":"315","year":"2016","journal-title":"JAMA"},{"key":"bib4-20230927","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1378\/chest.12-0299","article-title":"Dynamic expiratory tracheal collapse in COPD: correlation with clinical and physiologic parameters","volume":"142","year":"2012","journal-title":"Chest"},{"key":"bib5-20230927","first-page":"239","article-title":"Tracheobronchomalacia: untangling the Gordian knot","volume":"12","year":"2005","journal-title":"Journal of Bronchology & Interventional Pulmonology"},{"key":"bib6-20230927","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/S1052-3359(03)00036-X","article-title":"Tracheomalacia","volume":"13","year":"2003","journal-title":"Chest Surg Clin N Am"},{"key":"bib7-20230927","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1053\/j.semtcvs.2010.07.001","article-title":"Tracheobronchomalacia in adults","volume":"22","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"bib8-20230927","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.ejrad.2007.08.029","article-title":"Multi-detector CT evaluation in patients suspected of tracheobronchomalacia: comparison of end-expiratory with dynamic expiratory volumetric acquisitions","volume":"68","year":"2008","journal-title":"Eur J Radiol"},{"key":"bib9-20230927","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.crad.2013.11.003","article-title":"Static end-expiratory and dynamic forced expiratory tracheal collapse in COPD","volume":"69","year":"2014","journal-title":"Clin Radiol"},{"key":"bib10-20230927","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1097\/RTI.0000000000000325","article-title":"Improving quality of dynamic airway computed tomography using an expiratory airflow indicator device","volume":"33","year":"2018","journal-title":"J Thorac Imaging"},{"key":"bib11-20230927","doi-asserted-by":"crossref","first-page":"205","DOI":"10.2214\/ajr.176.1.1760205","article-title":"Tracheobronchomalacia: dynamic airway evaluation with multidetector CT","volume":"176","year":"2001","journal-title":"Am J Roentgenol"},{"key":"bib12-20230927","doi-asserted-by":"crossref","first-page":"E57","DOI":"10.21037\/jtd.2017.01.13","article-title":"Current concepts in severe adult tracheobronchomalacia: evaluation and treatment","volume":"9","year":"2017","journal-title":"J Thorac Dis"},{"key":"bib13-20230927","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","article-title":"Strategies for reducing radiation dose in CT","volume":"47","year":"2009","journal-title":"Radiol Clin North Am"},{"key":"bib14-20230927","first-page":"719","article-title":"2003 AUR Memorial Award. Dynamic expiratory volumetric CT imaging of the central airways: comparison of standard-dose and low-dose techniques","volume":"10","year":"2003","journal-title":"Acad Radiol"},{"key":"bib15-20230927","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1148\/radiol.2352040309","article-title":"Tracheobronchomalacia: comparison between end-expiratory and dynamic expiratory CT for evaluation of central airway collapse","volume":"235","year":"2005","journal-title":"Radiology"},{"key":"bib16-20230927","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1148\/radiol.2521081958","article-title":"Tracheal collapsibility in healthy volunteers during forced expiration: assessment with multidetector CT","volume":"252","year":"2009","journal-title":"Radiology"},{"key":"bib17-20230927","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.acra.2008.05.020","article-title":"Prevalence of tracheal collapse in an emphysema cohort as measured with end-expiration CT","volume":"16","year":"2009","journal-title":"Acad Radiol"},{"key":"bib18-20230927","doi-asserted-by":"crossref","first-page":"e49","DOI":"10.1016\/j.crad.2015.10.014","article-title":"Optimal imaging protocol for measuring dynamic expiratory collapse of the central airways","volume":"71","year":"2016","journal-title":"Clin Radiol"},{"key":"bib19-20230927","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1097\/00005382-200007000-00003","article-title":"Low-dose, dynamic, expiratory thin-section CT of the lungs using a spiral CT scanner","volume":"15","year":"2000","journal-title":"J Thorac Imaging"},{"key":"bib20-20230927","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1016\/j.acra.2009.11.014","article-title":"Comparison of standard-dose and reduced-dose expiratory MDCT techniques for assessment of tracheomalacia in children","volume":"17","year":"2010","journal-title":"Acad Radiol"},{"key":"bib21-20230927","doi-asserted-by":"crossref","first-page":"1407624","DOI":"10.1080\/20018525.2017.1407624","article-title":"Tracheal collapse diagnosed by multidetector computed tomography: evaluation of different image analysis methods","volume":"4","year":"2017","journal-title":"Eur Clin Respir J"},{"key":"bib22-20230927","doi-asserted-by":"crossref","first-page":"19","DOI":"10.6009\/jjrt.2013_JSRT_69.1.19","article-title":"Evaluation and examination of accuracy for the conversion factors of effective dose per dose-length product","volume":"69","year":"2013","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"bib24-20230927","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.4065\/mcp.2010.0260","article-title":"Radiation risk from medical imaging","volume":"85","year":"2010","journal-title":"Mayo Clin Proc"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004728-201903000-00023","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T18:21:01Z","timestamp":1695838861000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004728-201903000-00023"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000000806","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}