{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T12:49:43Z","timestamp":1758631783944},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The purpose of this study was to evaluate whether quantitative analysis of lower leg muscle enhancement measured from dynamic computed tomographic angiography (dyn-CTA) could be used for diagnosis of peripheral arterial occlusive disease.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Patients (N = 35) with known peripheral arterial occlusive disease underwent the dyn-CTA of calves first. Five minutes later, standard CTA of the peripheral runoff from the diaphragm to the toes was performed. A runoff score was assigned by radiologists as a reference standard for each of 4 lower leg artery segments. The lower leg muscle enhancement measured from the dyn-CTA was analyzed by using quantitative kinetic parameters, including initial enhancement (<jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub>), peak enhancement (<jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>peak<\/jats:sub>), and enhancement ratio (<jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>R<\/jats:sub>) calculated from average time attenuation curves. In addition, histogram of lower leg muscle enhancement was evaluated by using the first enhanced phase images.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Lower extremities were diagnosed as a normal group (n = 22) with each vessel segment score equals to 1 or lower and runoff score, 7 or lower, and otherwise as an ischemia group (n = 48). Average \u00b1 SD <jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub> is 91.4% \u00b1 8.5% and 82.3% \u00b1 10.7%, <jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>peak<\/jats:sub> is 122.7% \u00b1 10.4% and 115.6% \u00b1 11.1%, and <jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>R<\/jats:sub> is 0.75 \u00b1 0.05 and 0.72 \u00b1 0.09 for normal and ischemia group, respectively. Statistical analysis showed that average <jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub> and <jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>peak<\/jats:sub> for the ischemia group were significantly lower (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05) than the normal group. The histogram analysis demonstrated that mean and median of muscle enhancement in the ischemia group were significantly smaller (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05), and coefficient of variation (CV) was significantly larger (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05) than the normal group. There were weak negative correlations (<jats:italic toggle=\"yes\">r<\/jats:italic> = \u22120.42, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05) between runoff scores and <jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub> and <jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>peak<\/jats:sub>, and weak positive correlation (<jats:italic toggle=\"yes\">r<\/jats:italic> = 0.40, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05) between runoff scores and CV. The receiver operating characteristics analysis between the 2 groups had area under the curve of 0.77 and 0.76 for <jats:italic toggle=\"yes\">E<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub> and CV, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Lower leg muscle enhancement measured from the dyn-CTA could be assessed quantitatively to assist diagnosis of ischemia in clinical practice.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000000971","type":"journal-article","created":{"date-parts":[[2020,1,15]],"date-time":"2020-01-15T07:09:29Z","timestamp":1579072169000},"page":"20-25","source":"Crossref","is-referenced-by-count":6,"title":["Quantitative Analysis of Lower Leg Muscle Enhancement Measured From Dynamic Computed Tomographic Angiography for Diagnosis of Peripheral Arterial Occlusive Disease"],"prefix":"10.1097","volume":"44","author":[{"given":"Xueyan","family":"Zhou","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daming","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haiping","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zehong","family":"Lin","sequence":"additional","affiliation":[{"name":"College of Mechanical and Electrical Engineering, Harbin Engineering University, Harbin, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaobing","family":"Fan","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Chicago, Chicago, IL"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhengyu","family":"Jin","sequence":"additional","affiliation":[{"name":"Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20230927","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1016\/S0140-6736(13)61249-0","article-title":"Comparison of global estimates of prevalence and risk factors for peripheral artery disease in 2000 and 2010: a systematic review and analysis","volume":"382","year":"2013","journal-title":"Lancet"},{"key":"bib2-20230927","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1161\/CIRCRESAHA.116.303849","article-title":"Epidemiology of peripheral artery disease","volume":"116","year":"2015","journal-title":"Circ Res"},{"key":"bib3-20230927","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1001\/jama.295.2.180","article-title":"International prevalence, recognition, and treatment of cardiovascular risk factors in outpatients with atherothrombosis","volume":"295","year":"2006","journal-title":"JAMA"},{"key":"bib4-20230927","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1111\/j.1532-5415.2007.01092.x","article-title":"Lower extremity ischemia, calf skeletal muscle characteristics, and functional impairment in peripheral arterial disease","volume":"55","year":"2007","journal-title":"J Am Geriatr Soc"},{"key":"bib5-20230927","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.crad.2018.03.002","article-title":"Novel developments in non-invasive imaging of peripheral arterial disease with CT: experience with state-of-the-art, ultra-high-resolution CT and subtraction imaging","volume":"74","year":"2019","journal-title":"Clin Radiol"},{"key":"bib6-20230927","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1001\/jama.300.2.197","article-title":"Ankle brachial index combined with Framingham Risk Score to predict cardiovascular events and mortality: a meta-analysis","volume":"300","year":"2008","journal-title":"JAMA"},{"key":"bib7-20230927","first-page":"349","article-title":"Ultrasound duplex as a sole exam for surgical purposes in lower limb arterial obstructive disease","volume":"49","year":"2001","journal-title":"Minerva Cardioangiol"},{"key":"bib8-20230927","doi-asserted-by":"crossref","first-page":"2876","DOI":"10.1007\/s00330-010-1861-0","article-title":"Diagnostic value of time-resolved CT angiography for the lower leg","volume":"20","year":"2010","journal-title":"Eur Radiol"},{"key":"bib9-20230927","doi-asserted-by":"crossref","first-page":"2871","DOI":"10.1007\/s00330-015-4089-1","article-title":"3D non-contrast-enhanced ECG-gated MR angiography of the lower extremities with dual-source radiofrequency transmission at 3.0 T: Intraindividual comparison with contrast-enhanced MR angiography in PAOD patients","volume":"26","year":"2016","journal-title":"Eur Radiol"},{"key":"bib10-20230927","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1177\/1538574417698906","article-title":"CT angiography of peripheral arterial disease by 256-slice scanner: accuracy, advantages and disadvantages compared to digital subtraction angiography","volume":"51","year":"2017","journal-title":"Vasc Endovascular Surg"},{"key":"bib11-20230927","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1093\/eurheartj\/ehi636","article-title":"Contrast ultrasound perfusion imaging of lower extremities in peripheral arterial disease: a novel diagnostic method","volume":"27","year":"2006","journal-title":"Eur Heart J"},{"key":"bib12-20230927","doi-asserted-by":"crossref","first-page":"e0152780","DOI":"10.1371\/journal.pone.0152780","article-title":"Run-off computed tomography angiography (CTA) for discriminating the underlying causes of intermittent claudication","volume":"11","year":"2016","journal-title":"PLoS One"},{"key":"bib13-20230927","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1007\/s00330-007-0822-8","article-title":"Multidetector CT angiography in the assessment of peripheral arterial occlusive disease: accuracy in detecting the severity, number, and length of stenoses","volume":"18","year":"2008","journal-title":"Eur Radiol"},{"key":"bib14-20230927","doi-asserted-by":"crossref","first-page":"e147","DOI":"10.1016\/j.ejrad.2013.12.004","article-title":"Low contrast volume run-off CT angiography with optimized scan time based on double-level test bolus technique\u2014feasibility study","volume":"83","year":"2014","journal-title":"Eur J Radiol"},{"key":"bib15-20230927","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jvs.2016.03.420","article-title":"Reporting standards of the Society for Vascular Surgery for endovascular treatment of chronic lower extremity peripheral artery disease","volume":"64","year":"2016","journal-title":"J Vasc Surg"},{"key":"bib16-20230927","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.ejvs.2018.01.026","article-title":"Structured reporting of CT angiography runoff examinations of the lower extremities","volume":"55","year":"2018","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"bib17-20230927","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1007\/s00270-010-9925-8","article-title":"Dynamic computed tomography angiography: role in the evaluation of popliteal artery entrapment syndrome","volume":"34","year":"2011","journal-title":"Cardiovasc Intervent Radiol"},{"key":"bib18-20230927","doi-asserted-by":"crossref","first-page":"e0119900","DOI":"10.1371\/journal.pone.0119900","article-title":"Diagnostic confidence of run-off CT-angiography as the primary diagnostic imaging modality in patients presenting with acute or chronic peripheral arterial disease","volume":"10","year":"2015","journal-title":"PLoS One"},{"key":"bib19-20230927","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.3174\/ajnr.A4162","article-title":"4D-CTA in neurovascular disease: a review","volume":"36","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib20-20230927","doi-asserted-by":"crossref","first-page":"2421","DOI":"10.1016\/j.ejrad.2015.06.014","article-title":"From 3D to 4D: integration of temporal information into CT angiography studies","volume":"84","year":"2015","journal-title":"Eur J Radiol"},{"key":"bib21-20230927","first-page":"1120, 1122","article-title":"Strategies for reducing the CT radiation dose","volume":"50","year":"2010","journal-title":"Radiologe"},{"key":"bib22-20230927","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1097\/RLI.0b013e3182479c77","article-title":"Diagnostic accuracy of dynamic computed tomographic angiographic of the lower leg in patients with critical limb ischemia","volume":"47","year":"2012","journal-title":"Invest Radiol"},{"key":"bib23-20230927","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.ejrad.2018.11.030","article-title":"Improving the diagnosis of peripheral arterial disease in below-the-knee arteries by adding time-resolved CT scan series to conventional run-off CT angiography. First experience with a 256-slice CT scanner","volume":"110","year":"2019","journal-title":"Eur J Radiol"},{"key":"bib24-20230927","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1177\/0284185114535391","article-title":"Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography","volume":"56","year":"2015","journal-title":"Acta Radiol"},{"key":"bib25-20230927","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1007\/s00270-018-1979-z","article-title":"CT angiography in the lower extremity peripheral artery disease feasibility of an ultra-low volume contrast media protocol","volume":"41","year":"2018","journal-title":"Cardiovasc Intervent Radiol"},{"key":"bib26-20230927","doi-asserted-by":"crossref","first-page":"e99112","DOI":"10.1371\/journal.pone.0099112","article-title":"Image quality and radiation dose of lower extremity CT angiography using 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction","volume":"9","year":"2014","journal-title":"PLoS One"},{"key":"bib27-20230927","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1148\/radiol.14132903","article-title":"Estimates of effective dose for CT scans of the lower extremities","volume":"273","year":"2014","journal-title":"Radiology"},{"key":"bib28-20230927","doi-asserted-by":"crossref","first-page":"11904","DOI":"10.1118\/1.4770283","article-title":"Reduction of image noise in low tube current dynamic CT myocardial perfusion imaging using HYPR processing: a time-attenuation curve analysis","volume":"40","year":"2013","journal-title":"Med Phys"},{"key":"bib29-20230927","doi-asserted-by":"crossref","first-page":"832","DOI":"10.2214\/AJR.08.2025","article-title":"Kinetic curves of malignant lesions are not consistent across MRI systems: need for improved standardization of breast dynamic contrast-enhanced MRI acquisition","volume":"193","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"bib30-20230927","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/RLI.0000000000000216","article-title":"Dual-energy computed tomography angiography of the lower extremity runoff: impact of noise-optimized virtual monochromatic imaging on image quality and diagnostic accuracy","volume":"51","year":"2016","journal-title":"Invest Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000000971","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T18:23:27Z","timestamp":1695839007000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000000971"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000000971","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}