{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:40:09Z","timestamp":1754178009210,"version":"3.41.2"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>Compared the performance of computer-aided detection (CAD) software for quantitative analysis of airway using computed tomography (CT) images reconstructed with versions of model-based iterative reconstruction (MBIR) that either balances spatial and density resolution (MBIR<jats:sub>STND<\/jats:sub>) or prefers spatial resolution (MBIR<jats:sub>RP20<\/jats:sub>), and adaptive statistical iterative reconstruction (ASIR) with lung kernel.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Thirty patients were included who were scanned for pulmonary disease using a routine dose multidetector CT system. Data were reconstructed with ASIR, MBIR<jats:sub>STND<\/jats:sub>, and MBIR<jats:sub>RP20<\/jats:sub>. Airway dimensions from the 3 reconstructions were measured using an automated, quantitative CAD software designed to segment and quantify the bronchial tree automatically using a skeletonization algorithm. For each patient and reconstruction algorithm, the right middle lobe bronchus was selected as a representative for measuring the bronchial length of the matched airways. Two radiologists used a semiquantitative 5-point scale to rate the subjective image quality of MBIR<jats:sub>STND<\/jats:sub> and MBIR<jats:sub>RP20<\/jats:sub> reconstructions on airway trees analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Algorithm impacts the measurement variability of bronchus length in chest CT, MBIR<jats:sub>RP20<\/jats:sub> were the best, whereas ASIR were the worst (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05). In addition, the optimal reconstruction algorithm was found to be MBIR<jats:sub>STND<\/jats:sub> for the airway trees being assessed about subjective noise and MBIR<jats:sub>RP20<\/jats:sub> about bronchial end shows, and there were no significant differences in the continuity and completeness of bronchial wall, whereas ASIR performed inferiorly compared with them (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Compared with ASIR, MBIR<jats:sub>STND<\/jats:sub>, and MBIR<jats:sub>RP20<\/jats:sub> from MBIRn algorithm potentially allow the desired airway quantification accuracy to be achieved on the performance of CAD, especially for MBIR<jats:sub>RP20<\/jats:sub>.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000000975","type":"journal-article","created":{"date-parts":[[2020,1,10]],"date-time":"2020-01-10T13:33:41Z","timestamp":1578663221000},"page":"166-170","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Effect of New Model-Based Iterative Reconstruction on Quantitative Analysis of Airway Tree by Computer-Aided Detection Software in Chest Computed Tomography"],"prefix":"10.1097","volume":"45","author":[{"given":"Yongjun","family":"Jia","sequence":"first","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Shaanxi Chinese Medicine University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bingying","family":"Zhai","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Xianyang Hospital of Yan'an University, Xianyang"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taiping","family":"He","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Shaanxi Chinese Medicine University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Shaanxi Chinese Medicine University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nan","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Shaanxi Chinese Medicine University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haifeng","family":"Duan","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Shaanxi Chinese Medicine University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chuangbo","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Shaanxi Chinese Medicine University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian-ying","family":"Li","sequence":"additional","affiliation":[{"name":"CT Research Center, GE Healthcare China, Beijing, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20250802","first-page":"1303","article-title":"Computerized identification of bronchiectasis using a 3D quantitative CT protocol","volume":"6","year":"2016","journal-title":"J Med Imag Health Inform"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1002\/mp.12128","article-title":"The effect of radiation dose reduction on computer-aided detection (CAD) performance in a low-dose lung cancer screening population","volume":"44","year":"2017","journal-title":"Med Phys"},{"key":"bib3-20250802","first-page":"1","article-title":"Automated vessel tree segmentation: challenges in computer aided quantification of diffuse parenchyma lung diseases[C]\/\/ international conference on information technology and applications in biomedicine","year":"2009","journal-title":"IEEE"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1148\/radiol.2303021726","article-title":"Strategies for CT radiation dose optimization","volume":"230","year":"2004","journal-title":"Radiology"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"126","DOI":"10.2214\/AJR.09.3855","article-title":"Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study","volume":"195","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"2279","DOI":"10.1007\/s00261-017-1140-5","article-title":"Reduced dose CT with model-based iterative reconstruction compared to standard dose CT of the chest, abdomen, and pelvis in oncology patients: intra-individual comparison study on image quality and lesion conspicuity","volume":"42","year":"2017","journal-title":"Abdom Radiol (NY)"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/j.ejrad.2016.01.001","article-title":"High-resolution CT with new model-based iterative reconstruction with resolution preference algorithm in evaluations of lung nodules: comparison with conventional model-based iterative reconstruction and adaptive statistical iterative reconstruction","volume":"85","year":"2016","journal-title":"Eur J Radiol"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/j.media.2012.11.003","article-title":"Computerized identification of airway wall in CT examinations using a 3D active surface evolution approach","volume":"17","year":"2013","journal-title":"Med Image Anal"},{"key":"bib9-20250802","first-page":"1","article-title":"Effect of computed tomography dose on quantitative measurement and automated segmentation of airway tree","volume":"5","year":"2015","journal-title":"Journal of Medical Imaging & Health Informatics"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","article-title":"Strategies for reducing radiation dose in CT","volume":"47","year":"2009","journal-title":"Radiol Clin North Am"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.3174\/ajnr.A2585","article-title":"Lowering the dose in head CT using adaptive statistical iterative reconstruction","volume":"32","year":"2011","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1007\/s00330-011-2056-z","article-title":"Computed tomography\u2014old ideas and new technology","volume":"21","year":"2011","journal-title":"Eur Radiol"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1148\/radiol.12112707","article-title":"Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study","volume":"266","year":"2013","journal-title":"Radiology"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"971","DOI":"10.3174\/ajnr.A3320","article-title":"Improved delineation of arteries in the posterior fossa of the brain by model-based iterative reconstruction in volume-rendered 3D CT angiography","volume":"34","year":"2013","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"4457","DOI":"10.1007\/s00330-016-4307-5","article-title":"Submillisievert CT using model-based iterative reconstruction with lung-specific setting: an initial phantom study","volume":"26","year":"2016","journal-title":"Eur Radiol"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.crad.2017.01.002","article-title":"A review of lung cancer screening and the role of computer-aided detection","volume":"72","year":"2017","journal-title":"Clin Radiol"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"4148","DOI":"10.1002\/mp.12331","article-title":"Computerized detection of lung nodules through radiomics","volume":"44","year":"2017","journal-title":"Med Phys"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1007\/s00330-006-0496-7","article-title":"Quantification of bronchial dimensions at MDCT using dedicated software","volume":"17","year":"2007","journal-title":"Eur Radiol"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"97","DOI":"10.2147\/COPD.S2302","article-title":"Investigation of airways using MDCT for visual and quantitative assessment in COPD patients","volume":"3","year":"2008","journal-title":"Int J Chron Obstruct Pulmon Dis"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1016\/j.ejrad.2015.01.025","article-title":"Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom: influence of exposure parameters and iterative reconstruction","volume":"84","year":"2015","journal-title":"Eur J Radiol"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"645","DOI":"10.2214\/AJR.14.12590","article-title":"Hybrid and model-based iterative reconstruction techniques for pediatric CT","volume":"204","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.ejrad.2015.12.003","article-title":"Effect of radiation dose reduction and iterative reconstruction on computer-aided detection of pulmonary nodules: intra-individual comparison","volume":"85","year":"2016","journal-title":"Eur J Radiol"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"5919","DOI":"10.1118\/1.4930797","article-title":"Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: a phantom study","volume":"42","year":"2015","journal-title":"Med Phys"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1148\/radiol.2015141287","article-title":"Reduced radiation dose with model-based iterative reconstruction versus standard dose with adaptive statistical iterative reconstruction in abdominal CT for diagnosis of acute renal colic","volume":"276","year":"2015","journal-title":"Radiology"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000000975","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:22:19Z","timestamp":1754176939000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000000975"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000000975","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"type":"electronic","value":"1532-3145"},{"type":"print","value":"0363-8715"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}