{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T19:10:48Z","timestamp":1776539448438,"version":"3.51.2"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>The aim of this study was to investigate if Hounsfield unit (HU) values from virtual noncontrast (VNC) images derived from portal venous phase spectral-detector computed tomography can help to differentiate adrenal adenomas and metastases.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Spectral-detector computed tomography datasets of 33 patients with presence of adrenal lesions and standard of reference for lesion origin by follow-up\/prior examinations or dedicated magnetic resonance imaging were included. Conventional and VNC images were reconstructed from the same scan. Region of interest\u2013based image analysis was performed in adrenal lesions and contralateral healthy adrenal tissue.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The 33 lesions consisted of 23 adenomas and 10 metastases. Hounsfield unit values of all lesions in VNC images were significantly lower compared with conventional images (18.2 \u00b1 12.6 HU vs 59.6 \u00b1 21.7 HU, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). Hounsfield unit values in adenomas were significantly lower in VNC images (11.3 \u00b1 6.5 HU vs 34.1 \u00b1 9.1 HU, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Virtual noncontrast HU values differed significantly between adrenal adenomas and metastases and can therefore be used for improved characterization of incidental adrenal lesions and definition of adrenal adenomas.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000000982","type":"journal-article","created":{"date-parts":[[2020,3,12]],"date-time":"2020-03-12T23:23:16Z","timestamp":1584055396000},"page":"24-28","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":18,"title":["Virtual Noncontrast Images From Portal Venous Phase Spectral-Detector CT Acquisitions for Adrenal Lesion Characterization"],"prefix":"10.1097","volume":"45","author":[{"given":"Kai Roman","family":"Laukamp","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rivka","family":"Kessner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra","family":"Halliburton","sequence":"additional","affiliation":[{"name":"Philips Healthcare, CT Clinical Science, Cleveland, OH."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Zopfs","sequence":"additional","affiliation":[{"name":"Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amit","family":"Gupta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nils","family":"Gro\u00dfe Hokamp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"4324","DOI":"10.1007\/s00330-017-4785-0","article-title":"Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: a systematic review and meta-analysis","volume":"27","year":"2017","journal-title":"Eur Radiol"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.2214\/AJR.07.2799","article-title":"The incidental adrenal mass on CT: prevalence of adrenal disease in 1,049 consecutive adrenal masses in patients with no known malignancy","volume":"190","year":"2008","journal-title":"Am J Roentgenol"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1002\/jmri.23601","article-title":"Adrenal MRI: techniques and clinical applications","volume":"36","year":"2012","journal-title":"J Magn Reson Imaging"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1016\/j.crad.2014.06.020","article-title":"Pitfalls of adrenal imaging with chemical shift MRI","volume":"69","year":"2014","journal-title":"Clin Radiol"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"201","DOI":"10.2214\/ajr.171.1.9648789","article-title":"Characterization of adrenal masses using unenhanced CT: an analysis of the CT literature","volume":"171","year":"1998","journal-title":"AJR Am J Roentgenol"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"G1","DOI":"10.1530\/EJE-16-0467","article-title":"Management of adrenal incidentalomas: European Society of Endocrinology Clinical Practice Guideline in collaboration with the European network for the study of adrenal tumors","volume":"175","year":"2016","journal-title":"Eur J Endocrinol"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"122","DOI":"10.2214\/AJR.12.9620","article-title":"Can established CT attenuation and washout criteria for adrenal adenoma accurately exclude Pheochromocytoma?","volume":"201","year":"2013","journal-title":"Am J Roentgenol"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1007\/s00330-005-0017-0","article-title":"Adrenal masses falsely diagnosed as adenomas on unenhanced and delayed contrast-enhanced computed tomography: pathological correlation","volume":"16","year":"2006","journal-title":"Eur Radiol"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.jacr.2006.02.031","article-title":"ACR appropriateness criteria\u00ae on incidentally discovered adrenal mass","volume":"3","year":"2006","journal-title":"J Am Coll Radiol"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-energy CT: principles, technical approaches, and clinical applications","volume":"276","year":"2015","journal-title":"Radiology"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.2214\/AJR.12.9116","article-title":"Dual-energy CT: general principles","volume":"199","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1088\/0031-9155\/21\/5\/002","article-title":"Energy-selective reconstructions in x-ray computerized tomography","volume":"21","year":"1976","journal-title":"Phys Med Biol"},{"key":"bib13-20250802","article-title":"Virtual non-contrast for evaluation of liver parenchyma and vessels: results from 25 patients using multi-phase spectral-detector CT. Acta Radiologica. 2019. [Epub ahead of print]"},{"key":"bib14-20250802","first-page":"2066","article-title":"Assessment of arterially hyper-enhancing liver lesions using virtual monoenergetic images from spectral detector CT: phantom and patient experience","volume":"43","year":"2017","journal-title":"Abdom Radiol"},{"key":"bib15-20250802","article-title":"Technical background of a novel detector-based approach to dual-energy computed tomography","journal-title":"Diagnostic Interv Radiol"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1148\/radiol.14131480","article-title":"State of the art: dual-energy CT of the abdomen","volume":"271","year":"2014","journal-title":"Radiology"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"840","DOI":"10.2214\/AJR.11.7316","article-title":"Characterization of adrenal nodules with dual-energy CT: can virtual unenhanced attenuation values replace true unenhanced attenuation values?","volume":"198","year":"2012","journal-title":"Am J Roentgenol"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1148\/radiol.12112735","article-title":"Adenoma characterization: adrenal protocol with dual-energy CT","volume":"267","year":"2013","journal-title":"Radiology"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.ejrad.2018.05.007","article-title":"Dual-layer spectral computed tomography: virtual non-contrast in comparison to true non-contrast images","volume":"104","year":"2018","journal-title":"Eur J Radiol"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1007\/s00261-016-1036-9","article-title":"Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT","volume":"42","year":"2017","journal-title":"Abdom Radiol (NY)"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.1007\/s00330-011-2062-1","article-title":"Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation","volume":"21","year":"2011","journal-title":"Eur Radiol"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1097\/00004728-199405000-00017","article-title":"CT and MR distinction of adenomas and nonadenomas of the adrenal gland","volume":"18","year":"1994","journal-title":"J Comput Assist Tomogr"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1148\/radiology.179.2.2014283","article-title":"Benign and malignant adrenal masses: CT distinction with attenuation coefficients, size, and observer analysis","volume":"179","year":"1991","journal-title":"Radiology"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"671","DOI":"10.2214\/ajr.182.3.1820671","article-title":"CT density measurements for characterization of adrenal tumors ex vivo: variability among three CT scanners","volume":"182","year":"2004","journal-title":"Am J Roentgenol"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1148\/radiol.2283020878","article-title":"Adrenal masses: CT characterization with histogram analysis method","volume":"228","year":"2003","journal-title":"Radiology"},{"key":"bib26-20250802","doi-asserted-by":"crossref","first-page":"2098","DOI":"10.1007\/s00330-018-5744-0","article-title":"Precision and reliability of liver iodine quantification from spectral detector CT: evidence from phantom and patient data","volume":"29","year":"2019","journal-title":"Eur Radiol"},{"key":"bib27-20250802","doi-asserted-by":"crossref","first-page":"1746","DOI":"10.1016\/j.ejrad.2014.06.017","article-title":"Incidental adrenal lesions detected on enhanced abdominal dual-energy CT: can the diagnostic workup be shortened by the implementation of virtual unenhanced images?","volume":"83","year":"2014","journal-title":"Eur J Radiol"},{"key":"bib28-20250802","doi-asserted-by":"crossref","first-page":"594.e7","DOI":"10.1016\/j.crad.2018.01.018","article-title":"Single-energy non-contrast hepatic steatosis criteria applied to virtual non-contrast images: is it still highly specific and positively predictive?","volume":"73","year":"2018","journal-title":"Clin Radiol"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.2214\/AJR.17.18248","article-title":"Abdominal attenuation values on virtual and true unenhanced images obtained with third-generation dual-source dual-energy CT","volume":"210","year":"2018","journal-title":"Am J Roentgenol"},{"key":"bib30-20250802","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1148\/radiol.2017170896","article-title":"Intermanufacturer comparison of dual-energy CT iodine quantification and monochromatic attenuation: a phantom study","volume":"287","year":"2018","journal-title":"Radiology"},{"key":"bib31-20250802","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1097\/RLI.0000000000000446","article-title":"Comparison of iodine density measurement among dual-energy computed tomography scanners from 3 vendors","volume":"53","year":"2018","journal-title":"Invest Radiol"},{"key":"bib32-20250802","article-title":"Evaluation of the liver with virtual non-contrast: single institution study in 149 patients undergoing TAVR planning","year":"2019","journal-title":"Br J Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000000982","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:22:19Z","timestamp":1754176939000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000000982"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000000982","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}