{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T09:15:33Z","timestamp":1768295733158,"version":"3.49.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>To create a map of iodine densities within affected segments of small-bowel Crohn disease (CD) derived from contrast-enhanced dual-energy computed tomography enterography (DECTE) studies.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Twenty CD patients imaged with intravenous contrast-enhanced DECTE between June 2016 and December 2017 were retrospectively identified. Ten patients without clinical evidence of CD and 8 normal-appearing jejunal segments in CD patients were controls. Using prototype software, 8 manual contours were drawn along the mucosa of affected segments. Relatively normal-appearing bowel was included at the edges. These contours served as a basis for iodine density calculation and 3-dimensional iodine density map rendering. Color-coded iodine densities allowed detection and quantification of the most and least dense portion of each segment and also permitted relative comparison between segments.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The average iodine density per CD involved segment ranged 1.0 to 3.3 mg\/mL, which differed significantly from normal ileum (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.0001) and normal-appearing jejunum in patients with CD (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0009). Standard deviations ranged from 0.8 to 1.7 mg\/mL, which differed significantly from normal ileum (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0039) and normal-appearing jejunum in patients with CD (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0056). The amplitude of the power spectrum ranged from 0.66 to 3.3 demonstrating patches of iodine rather than uniform distribution. This differed significantly from normal ileum (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0005) and normal-appearing jejunum in patients with CD (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0004).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Heterogeneous CD activity and distribution can be displayed as iodine density maps created from DECTE.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001009","type":"journal-article","created":{"date-parts":[[2020,8,3]],"date-time":"2020-08-03T17:23:24Z","timestamp":1596475404000},"page":"772-779","source":"Crossref","is-referenced-by-count":10,"title":["Novel Dual-Energy Computed Tomography Enterography Iodine Density Maps Provide Unique Depiction of Crohn Disease Activity"],"prefix":"10.1097","volume":"44","author":[{"given":"Bari","family":"Dane","sequence":"first","affiliation":[{"name":"Department of Radiology, NYU Langone Health, New York, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"O'Donnell","sequence":"additional","affiliation":[{"name":"Siemens Healthineers, Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justin","family":"Ream","sequence":"additional","affiliation":[{"name":"Department of Radiology, NYU Langone Health, New York, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shannon","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, NYU Langone Health, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alec","family":"Megibow","sequence":"additional","affiliation":[{"name":"Department of Radiology, NYU Langone Health, New York, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,7,31]]},"reference":[{"key":"bib1-20230927","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1148\/rg.243035120","article-title":"Cross-sectional imaging in Crohn disease","volume":"24","year":"2004","journal-title":"Radiographics"},{"key":"bib2-20230927","doi-asserted-by":"crossref","first-page":"1504","DOI":"10.1053\/j.gastro.2004.01.063","article-title":"Clinical epidemiology of inflammatory bowel disease: incidence, prevalence, and environmental influences","volume":"126","year":"2004","journal-title":"Gastroenterology"},{"key":"bib3-20230927","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1148\/radiol.2018171737","article-title":"Consensus recommendations for evaluation, interpretation, and utilization of computed tomography and magnetic resonance enterography in patients with small bowel Crohn's disease","volume":"286","year":"2018","journal-title":"Radiology"},{"key":"bib4-20230927","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1053\/crad.2002.1068","article-title":"Bowel wall thickening in patients with Crohn's disease: CT patterns and correlation with inflammatory activity","volume":"58","year":"2003","journal-title":"Clin Radiol"},{"key":"bib5-20230927","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1148\/radiol.2413051444","article-title":"Active Crohn disease: CT findings and interobserver agreement for enteric phase CT enterography","volume":"241","year":"2006","journal-title":"Radiology"},{"key":"bib6-20230927","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1148\/radiol.2382041159","article-title":"Crohn disease: mural attenuation and thickness at contrast-enhanced CT enterography\u2014correlation with endoscopic and histologic findings of inflammation","volume":"238","year":"2006","journal-title":"Radiology"},{"key":"bib7-20230927","doi-asserted-by":"crossref","first-page":"1977","DOI":"10.1007\/s00330-017-5151-y","article-title":"Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?","volume":"28","year":"2018","journal-title":"Eur Radiol"},{"key":"bib8-20230927","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1097\/RLI.0000000000000176","article-title":"Correlation of quantitative dual-energy computed tomography iodine maps and abdominal computed tomography perfusion measurements: are single-acquisition dual-energy computed tomography iodine maps more than a reduced-dose surrogate of conventional computed tomography perfusion?","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib9-20230927","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.3348\/kjr.2018.19.6.1077","article-title":"Iodine quantification on spectral detector-based dual-energy CT enterography: correlation with Crohn's disease activity index and external validation","volume":"19","year":"2018","journal-title":"Korean J Radiol"},{"key":"bib10-20230927","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1016\/j.cgh.2012.03.026","article-title":"Endoscopic skipping of the distal terminal ileum in Crohn's disease can lead to negative results from ileocolonoscopy","volume":"10","year":"2012","journal-title":"Clin Gastroenterol Hepatol"},{"key":"bib11-20230927","year":"2008","journal-title":"The Measurement, Reporting, and Management of Radiation Dose in CT AAPM Report No 96"},{"key":"bib12-20230927","doi-asserted-by":"crossref","first-page":"2525","DOI":"10.1007\/s00330-017-5215-z","article-title":"Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn's disease","volume":"28","year":"2018","journal-title":"Eur Radiol"},{"key":"bib13-20230927","doi-asserted-by":"crossref","first-page":"W663","DOI":"10.2214\/AJR.14.13674","article-title":"High spatiotemporal resolution dynamic contrast-enhanced MR enterography in Crohn disease terminal ileitis using continuous golden-angle radial sampling, compressed sensing, and parallel imaging","volume":"204","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"bib14-20230927","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1148\/radiol.2015151560","article-title":"Correlation between dual-energy and perfusion CT in patients with hepatocellular carcinoma","volume":"280","year":"2016","journal-title":"Radiology"},{"key":"bib15-20230927","doi-asserted-by":"crossref","first-page":"2532","DOI":"10.1007\/s00330-016-4597-7","article-title":"Dual energy CT allows for improved characterization of response to antiangiogenic treatment in patients with metastatic renal cell cancer","volume":"27","year":"2017","journal-title":"Eur Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T18:33:58Z","timestamp":1695839638000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,31]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001009","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2020,7,31]]}}}