{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,7]],"date-time":"2026-03-07T01:53:34Z","timestamp":1772848414699,"version":"3.50.1"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>This study aimed to compare the feasibility, safety, diagnostic accuracy, and radiation dose between computed tomography (CT) fluoroscopy (CTF)\u2013guided and conventional CT (CCT)\u2013guided lung biopsy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Relevant articles up until February 2020 were identified within the PubMed, Embase, and Cochrane Library databases. Diagnostic accuracy rate, pneumothorax, and pneumothorax requiring chest tube served as primary end points, with technical success, hemoptysis, operative time, and radiation dose serving as secondary end points. Pooled odds ratios (ORs) were calculated for the dichotomous variables. Pooled estimates of the mean difference (MD) were measured for the continuous variables.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>This meta-analysis included 9 studies. Seven studies were retrospective, and 2 studies were randomized controlled trials. A total of 6998 patients underwent either CTF-guided (n = 3858) or CCT-guided (n = 3154) lung biopsy. The diagnostic accuracy rate was significantly higher in the CTF group compared with the CCT group (OR, 0.32; <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.00001). No significant differences were detected between the CTF and CCT groups in terms of incidence rates of pneumothorax (OR, 0.95; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.84), rates of pneumothorax requiring chest tube insertion (OR, 0.95; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.84), technical success rates (OR, 0.41; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.15), incidence rates of hemoptysis (OR, 1.19; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.61), operative time (MD, \u22124.38; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.24), and radiation dose (MD, 158.60; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.42). A publication bias was found for the end points of pneumothorax requiring chest tube insertion and operative time.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Compared with CCT-guided lung biopsy, CTF-guided lung biopsy could yield a higher diagnostic accuracy with similar safety and radiation exposure.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001044","type":"journal-article","created":{"date-parts":[[2020,6,19]],"date-time":"2020-06-19T22:31:18Z","timestamp":1592605878000},"page":"571-577","source":"Crossref","is-referenced-by-count":20,"title":["Computed Tomography Fluoroscopy\u2013Guided Versus Conventional Computed Tomography\u2013Guided Lung Biopsy: A Systematic Review and Meta-analysis"],"prefix":"10.1097","volume":"44","author":[{"given":"Yu-Fei","family":"Fu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guang-Chao","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Cao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi-Bing","family":"Shi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,6,18]]},"reference":[{"key":"bib1-20230927","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1148\/radiol.2253011465","article-title":"CT-guided percutaneous fine-needle aspiration biopsy of small (< or = 1-cm) pulmonary lesions","volume":"225","year":"2002","journal-title":"Radiology"},{"key":"bib2-20230927","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.carj.2015.10.005","article-title":"Transthoracic computed tomography\u2013guided lung nodule biopsy: comparison of core needle and fine needle aspiration techniques","volume":"67","year":"2016","journal-title":"Can Assoc Radiol J"},{"key":"bib3-20230927","doi-asserted-by":"crossref","first-page":"e43","DOI":"10.1016\/j.crad.2012.09.008","article-title":"CT-guided percutaneous core needle biopsy for small (\u226420 mm) pulmonary lesions","volume":"68","year":"2013","journal-title":"Clin Radiol"},{"key":"bib4-20230927","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.jvir.2016.01.134","article-title":"Diagnostic accuracy and safety of CT-guided percutaneous transthoracic needle biopsies: 14-gauge versus 22-gauge needles","volume":"27","year":"2016","journal-title":"J Vasc Interv Radiol"},{"key":"bib5-20230927","doi-asserted-by":"crossref","first-page":"333","DOI":"10.21037\/jtd.2017.02.16","article-title":"CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing","volume":"9","year":"2017","journal-title":"J Thorac Dis"},{"key":"bib6-20230927","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s12032-016-0871-4","article-title":"Extra-pleuric coaxial system for CT-guided percutaneous fine-needle aspiration biopsy (FNAB) of small (\u226420 mm) lung nodules: a novel technique using multiplanar reconstruction (MPR) images","volume":"34","year":"2017","journal-title":"Med Oncol"},{"key":"bib7-20230927","doi-asserted-by":"crossref","first-page":"724","DOI":"10.21037\/jtd.2019.02.58","article-title":"CT-guided fine-needle aspiration biopsy of solitary pulmonary nodules under 15 mm in diameter: time for an afterthought?","volume":"11","year":"2019","journal-title":"J Thorac Dis"},{"key":"bib8-20230927","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1097\/JTO.0b013e318233d7dd","article-title":"Percutaneous computed tomography-guided coaxial core biopsy for small pulmonary lesions with ground-glass attenuation","volume":"7","year":"2012","journal-title":"J Thorac Oncol"},{"key":"bib9-20230927","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1007\/s11547-013-0965-4","article-title":"Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules","volume":"118","year":"2013","journal-title":"Radiol Med"},{"key":"bib10-20230927","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/S0720-048X(03)00216-X","article-title":"Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules","volume":"51","year":"2004","journal-title":"Eur J Radiol"},{"key":"bib11-20230927","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1007\/s00330-010-1936-y","article-title":"CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance","volume":"21","year":"2011","journal-title":"Eur Radiol"},{"key":"bib12-20230927","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1148\/radiology.212.3.r99se36673","article-title":"CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure","volume":"212","year":"1999","journal-title":"Radiology"},{"key":"bib13-20230927","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/S1051-0443(98)70383-5","article-title":"Real-time CT-fluoroscopy for guidance of percutaneous drainage procedures","volume":"9","year":"1998","journal-title":"J Vasc Interv Radiol"},{"key":"bib14-20230927","doi-asserted-by":"crossref","first-page":"637","DOI":"10.2214\/ajr.173.3.10470894","article-title":"Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance","volume":"173","year":"1999","journal-title":"AJR Am J Roentgenol"},{"key":"bib15-20230927","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1016\/j.ejrad.2011.01.064","article-title":"CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose","volume":"81","year":"2012","journal-title":"Eur J Radiol"},{"key":"bib16-20230927","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1007\/s00330-006-0152-2","article-title":"Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses","volume":"16","year":"2006","journal-title":"Eur Radiol"},{"key":"bib17-20230927","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/S0720-048X(01)00391-6","article-title":"Guidance of percutaneous pulmonary biopsies with real-time CT fluoroscopy","volume":"42","year":"2002","journal-title":"Eur J Radiol"},{"key":"bib18-20230927","doi-asserted-by":"crossref","first-page":"S166","DOI":"10.1016\/j.jvir.2015.12.431","article-title":"Comparison of radiation dose, procedure time and diagnostic yield of conventional CT-guided lung biopsy with CT fluoroscopy-guided lung biopsy","volume":"27","year":"2016","journal-title":"J Vasc Interv Radiol"},{"key":"bib19-20230927","doi-asserted-by":"crossref","first-page":"S202","DOI":"10.1016\/j.jvir.2013.12.545","article-title":"CT fluoroscopy guidance versus conventional CT guidance for percutaneous pulmonary nodule biopsy\u2014a comparison of patient radiation exposure, procedural time, and complication rates","volume":"25","year":"2014","journal-title":"J Vasc Interv Radiol"},{"key":"bib20-20230927","doi-asserted-by":"crossref","first-page":"323","DOI":"10.3348\/kjr.2018.0064","article-title":"Analysis of complications of percutaneous transthoracic needle biopsy using CT-guidance modalities in a multicenter cohort of 10568 biopsies","volume":"20","year":"2019","journal-title":"Korean J Radiol"},{"key":"bib21-20230927","first-page":"A4432","article-title":"Comparison of CT and CT-fluoroscopy guided percutaneous biopsy for lung cancer diagnosis","volume":"185","year":"2012","journal-title":"Am J Respir Crit Care Med"},{"key":"bib22-20230927","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1007\/s00270-017-1827-6","article-title":"A systematic review and meta-analysis of intraluminal brachytherapy versus stent alone in the treatment of malignant obstructive jaundice","volume":"41","year":"2018","journal-title":"Cardiovasc Intervent Radiol"},{"key":"bib23-20230927","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1007\/s00330-019-06377-4","article-title":"Diagnostic outcome and safety of CT-guided core needle biopsy for mediastinal masses: a systematic review and meta-analysis","volume":"30","year":"2020","journal-title":"Eur Radiol"},{"key":"bib24-20230927","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1097\/01.RVI.0000071087.76348.C7","article-title":"Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures","volume":"14","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"bib25-20230927","doi-asserted-by":"crossref","first-page":"1584","DOI":"10.1007\/s00330-019-06464-6","article-title":"Computed tomography-guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol","volume":"30","year":"2020","journal-title":"Eur Radiol"},{"key":"bib26-20230927","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1007\/s00330-016-4357-8","article-title":"Complication rates of CT-guided transthoracic lung biopsy: meta-analysis","volume":"27","year":"2017","journal-title":"Eur Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001044","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T18:26:58Z","timestamp":1695839218000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001044"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,18]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001044","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6,18]]}}}