{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T15:59:12Z","timestamp":1791907152646,"version":"4.3.4"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2021,7]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>We explored the feasibility of cardiac computed tomography (CCT) to evaluate postoperative ventricular function in children with congenital heart disease (CHD) and evaluated the accuracy and reproducibility of CCT using cardiac magnetic resonance (CMR) as a reference.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Thirty-two postoperative children with CHD (20 boys and 12 girls) who underwent CMR and CCT were enrolled. Left and right ventricular ejection fraction, end-diastolic volume, end-systolic volume, stroke volume, and cardiac index were measured using cardiac function analysis software. Cardiac function data were compared between CMR and CCT. The agreement between the 2 modalities was assessed using a Bland-Altman analysis. Intraclass correlation coefficients were used to assess intraobserver and interobserver reproducibility in CCT functional measurements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      All functional parameters showed no significant difference (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; 0.05) and were well-correlated (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      &gt; 0.5,\n                      <jats:italic toggle=\"yes\">P &lt;<\/jats:italic>\n                      0.05) between CMR and CCT. The mean values of all ventricular function parameters in CCT were higher compared with CMR. As indicated by 95% limits of agreement, left ventricular function parameters showed a better level of agreement compared with right ventricular function parameters between the 2 modalities. Intraobserver and interobserver reproducibility were excellent in CCT measurements for all functional parameters (intraclass correlation coefficient &gt; 0.9).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Compared with the criterion standard of CMR, CCT is feasible for assessing postoperative ventricular function with sufficient diagnostic accuracy and reproducibility in children with CHD. In addition to its important role regarding anatomical characterization, CCT is a suitable alternative and convenient follow-up tool that can be used to functional evaluation in children who are intolerant with CMR or have contraindications to CMR.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001155","type":"journal-article","created":{"date-parts":[[2021,5,19]],"date-time":"2021-05-19T18:27:10Z","timestamp":1621448830000},"page":"537-543","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Feasibility of Cardiac Computed Tomography for the Evaluation of Ventricular Function in Postoperative Children With Congenital Heart Disease: Comparison With Cardiac Magnetic Resonance Imaging"],"prefix":"10.1097","volume":"45","author":[{"given":"Wei-Hui","family":"Xie","sequence":"first","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Guo","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-Wei","family":"Hu","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rong-Zhen","family":"Ouyang","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao-Fen","family":"Yao","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ai-Min","family":"Sun","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hai-Sheng","family":"Qiu","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qin","family":"Yan","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Thoracic Surgery, Shanghai Children's Medical Center affiliated with Shanghai Jiao Tong University School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ya-Xin","family":"Zhu","sequence":"additional","affiliation":[{"name":"Canon Medical Systems, Zhongshan Wanbo International Center, Shanghai, P.R. China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Wang","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu-Min","family":"Zhong","sequence":"additional","affiliation":[{"name":"Diagnostic Imaging Center"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1016\/S0735-1097(02)01886-7","article-title":"The incidence of congenital heart disease","volume":"39","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1016\/j.jacc.2011.08.025","article-title":"Birth prevalence of congenital heart disease worldwide: a systematic review and meta-analysis","volume":"58","year":"2011","journal-title":"J Am Coll Cardiol"},{"issue":"Suppl 2","key":"bib3-20250802","first-page":"145","article-title":"Analysis of outcomes for congenital cardiac disease: can we do better?","volume":"17","year":"2007","journal-title":"Cardiol Young"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1093\/cvr\/cvx155","article-title":"Origins and consequences of congenital heart defects affecting the right ventricle","volume":"113","year":"2017","journal-title":"Cardiovasc Res"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1161\/CIRCIMAGING.109.875021","article-title":"Multimodality noninvasive imaging for assessment of congenital heart disease","volume":"3","year":"2010","journal-title":"Circ Cardiovasc Imaging"},{"issue":"Suppl 2","key":"bib6-20250802","first-page":"S111","article-title":"Limitation of transthoracic echocardiography in the diagnosis of congenital heart diseases","volume":"83","year":"2000","journal-title":"J Med Assoc Thail"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1161\/01.CIR.69.3.497","article-title":"Echocardiographic measurements of right ventricular volumes","volume":"69","year":"1984","journal-title":"Circulation"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1148\/radiol.2233011181","article-title":"Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility","volume":"223","year":"2002","journal-title":"Radiology"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1258\/ar.2012.120452","article-title":"Current trends in cardiac CT in children","volume":"54","year":"2013","journal-title":"Acta Radiol"},{"issue":"2\u20134","key":"bib10-20250802","first-page":"1","article-title":"The 2007 Recommendations of the International Commission on Radiological Protection","volume":"37","year":"2007","journal-title":"Ann ICRP"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1007\/s00247-008-0794-0","article-title":"Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method","volume":"38","year":"2008","journal-title":"Pediatr Radiol"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1161\/hc1102.105289","article-title":"New concepts in diastolic dysfunction and diastolic heart failure: part I: diagnosis, prognosis, and measurements of diastolic function","volume":"105","year":"2002","journal-title":"Circulation"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.jcmg.2010.11.017","article-title":"Feasibility of diastolic function assessment with cardiac CT: feasibility study in comparison with tissue Doppler imaging","volume":"4","year":"2011","journal-title":"JACC Cardiovasc Imaging"},{"issue":"Suppl 1","key":"bib14-20250802","first-page":"I56","article-title":"Ventricular diastolic stiffness predicts perioperative morbidity and duration of pleural effusions after the Fontan operation","volume":"114","year":"2006","journal-title":"Circulation"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"20180201","DOI":"10.1259\/bjr.20180201","article-title":"Computed tomography in paediatric heart disease","volume":"91","year":"2018","journal-title":"Br J Radiol"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"3289","DOI":"10.1007\/s00330-014-3344-1","article-title":"Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-tesla MRI","volume":"24","year":"2014","journal-title":"Eur Radiol"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"71","DOI":"10.5090\/kjtcs.2017.50.2.71","article-title":"Use of cardiac computed tomography for ventricular Volumetry in late postoperative patients with tetralogy of Fallot","volume":"50","year":"2017","journal-title":"Korean J Thorac Cardiovasc Surg"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"102","DOI":"10.3348\/kjr.2018.0237","article-title":"Semiautomatic three-dimensional threshold-based cardiac computed tomography ventricular volumetry in repaired tetralogy of Fallot: comparison with cardiac magnetic resonance imaging","volume":"20","year":"2019","journal-title":"Korean J Radiol"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1007\/s00330-007-0767-y","article-title":"Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings","volume":"18","year":"2008","journal-title":"Eur Radiol"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1016\/j.athoracsur.2004.09.030","article-title":"Multislice computed tomography for preoperative evaluation of right ventricular volumes and function: comparison with magnetic resonance imaging","volume":"79","year":"2005","journal-title":"Ann Thorac Surg"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"2087","DOI":"10.1007\/s00330-008-0982-1","article-title":"Global left-ventricular function assessment using dual-source multidetector CT: effect of improved temporal resolution on ventricular volume measurement","volume":"18","year":"2008","journal-title":"Eur Radiol"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.ijcard.2008.10.031","article-title":"Accuracy and reproducibility of assessing right ventricular function with 64-section multi-detector row CT: comparison with magnetic resonance imaging","volume":"139","year":"2010","journal-title":"Int J Cardiol"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1016\/j.ahj.2005.04.029","article-title":"Multi-detector row cardiac computed tomography accurately quantifies right and left ventricular size and function compared with cardiac magnetic resonance","volume":"151","year":"2006","journal-title":"Am Heart J"},{"key":"bib24-20250802","first-page":"1421","article-title":"Radiation dose reduction at pediatric CT: use of low tube voltage and iterative reconstruction [published correction appears in radiographics. 2019 May-June;39(3):912]","volume":"38","year":"2018","journal-title":"Radiographics"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1148\/rg.287085042","article-title":"Quality initiatives* radiation risk: what you should know to tell your patient","volume":"28","year":"2008","journal-title":"Radiographics"},{"key":"bib26-20250802","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1016\/j.crad.2017.01.017","article-title":"Prospective ECG-triggering cardiac CT for infants with complex congenital heart disease using low-dose contrast medium, low tube voltage, and adaptive statistical iterative reconstruction","volume":"72","year":"2017","journal-title":"Clin Radiol"},{"key":"bib27-20250802","doi-asserted-by":"crossref","first-page":"13761","DOI":"10.1073\/pnas.2235592100","article-title":"Cancer risks attributable to low doses of ionizing radiation: assessing what we really know","volume":"100","year":"2003","journal-title":"Proc Natl Acad Sci U S A"},{"key":"bib28-20250802","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1007\/s10554-016-0854-8","article-title":"Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease","volume":"32","year":"2016","journal-title":"Int J Card Imaging"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1007\/s00330-004-2543-6","article-title":"Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging","volume":"15","year":"2005","journal-title":"Eur Radiol"},{"key":"bib30-20250802","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1148\/radiol.10091848","article-title":"Delayed adverse reaction to contrast-enhanced CT: a prospective single-center study comparison to control group without enhancement","volume":"255","year":"2010","journal-title":"Radiology"},{"key":"bib31-20250802","doi-asserted-by":"crossref","first-page":"3189","DOI":"10.1161\/CIRCULATIONAHA.106.671644","article-title":"Investigators of the CARE study. Cardiac angiography in renally impaired patients (CARE) study: a randomized double-blind trial of contrast-induced nephropathy in patients with chronic kidney disease","volume":"115","year":"2007","journal-title":"Circulation"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001155","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:21:30Z","timestamp":1754176890000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001155"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001155","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2021,7]]}}}