{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T23:39:41Z","timestamp":1783381181616,"version":"3.54.6"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>This study aimed to assess the diagnostic accuracy of magnetic resonance elastography (MRE) in detecting hepatic fibrosis and determining clinically relevant stiffness cutoff values per stage of fibrosis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This retrospective study assessed 1488 hepatic MRE evaluations performed at a single institution for 5 years. Mean liver stiffness measurements were collected from 282 patients who had an MRE study within 1 year of histopathologic analysis. Areas under receiver operating characteristic curves were calculated for each stage of fibrosis with nonparametric ordinal measures of accuracy, and Youden Index was determined.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Mean liver stiffness measurement values were as follows: F0, 2.5\u00b1 0.55 kPa; F1, 3.1\u00b1 0.80 kPa; F2, 3.4\u00b10.95 kPa; F3, 4.7\u00b11.44 kPa; and F4, 7.9\u00b1 2.64 kPa. Nonparametric ordinal measures of accuracy per fibrosis stage were as follows: F0: 0.934, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001; F0\u2013F1: 0.917, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001; F0\u2013F2: 0.944, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001; and F0\u2013F3: 0.941, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001. Youden Index values for fibrosis stages F2, F3, and F4 were 3.9, 4.0, and 4.5 kPa, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Magnetic resonance elastography is an accurate diagnostic tool in assessing liver fibrosis.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001228","type":"journal-article","created":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T16:34:31Z","timestamp":1632760471000},"page":"1-5","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Magnetic Resonance Elastography of the Liver: A Single-Institution Review of Cases Performed in a 5-Year Interval"],"prefix":"10.1097","volume":"46","author":[{"given":"Carlos","family":"Morillo-Hernandez","sequence":"first","affiliation":[{"name":"University of Pittsburgh School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberta","family":"Catania","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip J.","family":"Grosse","sequence":"additional","affiliation":[{"name":"University of Pittsburgh Clinical and Translational Science Institute, Pittsburgh, PA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gideon","family":"Bollino","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir A.","family":"Borhani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Furlan","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,9,27]]},"reference":[{"key":"bib1-20250802","first-page":"1","article-title":"Deaths: leading causes for 2017","volume":"68","year":"2019","journal-title":"Natl Vital Stat Rep"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"1987","DOI":"10.1148\/rg.2016160042","article-title":"Elastography in chronic liver disease: modalities, techniques, limitations, and future directions","volume":"36","year":"2016","journal-title":"Radiographics"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1097\/RMR.0000000000000149","article-title":"Liver fibrosis quantification by magnetic resonance imaging","volume":"26","year":"2017","journal-title":"Top Magn Reson Imaging"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s11894-018-0652-7","article-title":"Imaging of hepatic fibrosis","volume":"20","year":"2018","journal-title":"Curr Gastroenterol Rep"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"1590","DOI":"10.1007\/s00261-017-1383-1","article-title":"Magnetic resonance elastography: beyond liver fibrosis\u2014a case-based pictorial review","volume":"43","year":"2018","journal-title":"Abdom Radiol"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1016\/j.cgh.2013.07.034","article-title":"Liver stiffness is associated with risk of decompensation, liver cancer, and death in patients with chronic liver diseases: a systematic review and meta-analysis","volume":"11","year":"2013","journal-title":"Clin Gastroenterol Hepatol"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"3444","DOI":"10.1007\/s00261-020-02656-7","article-title":"MR elastography of liver: current status and future perspectives","volume":"45","year":"2020","journal-title":"Abdom Radiol"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1016\/S0140-6736(96)07642-8","article-title":"Natural history of liver fibrosis progression in patients with chronic hepatitis C","volume":"349","year":"1997","journal-title":"Lancet"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1016\/j.acra.2005.05.013","article-title":"Estimating and comparing diagnostic tests' accuracy when the gold standard is not binary","volume":"12","year":"2005","journal-title":"Acad Radiol"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"2037","DOI":"10.1007\/s00261-017-1211-7","article-title":"Evaluation of hepatic fibrosis: a review from the society of abdominal radiology disease focus panel","volume":"42","year":"2017","journal-title":"Abdom Radiol"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.cgh.2014.09.046","article-title":"Diagnostic performance of magnetic resonance elastography in staging liver fibrosis: a systematic review and meta-analysis of individual participant data","volume":"13","year":"2015","journal-title":"Clin Gastroenterol Hepatol"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1148\/radiol.2015142141","article-title":"Hepatic MR elastography: clinical performance in a series of 1377 consecutive examinations","volume":"278","year":"2016","journal-title":"Radiology"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1148\/radiol.2016160863","article-title":"Technical failure of MR elastography examinations of the liver: experience from a large single-center study","volume":"284","year":"2017","journal-title":"Radiology"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1097\/RLI.0000000000000269","article-title":"Magnetic resonance elastography of the liver: qualitative and quantitative comparison of gradient echo and spin echo echoplanar imaging sequences","volume":"51","year":"2016","journal-title":"Invest Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001228","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:18:25Z","timestamp":1754176705000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001228"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,27]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001228","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2021,9,27]]}}}