{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T19:57:27Z","timestamp":1784404647118,"version":"3.55.0"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>The aim of the study was to compare a pediatric ultralow-dose pectus excavatum computed tomography (CT) protocol versus standard-dose pediatric thoracic CT in terms of radiation dose, subjective and objective image quality, and its ability to detect incidental nonosseous thoracic pathology compared with imaging and clinical reference.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A single institution radiology database identified a total of 104 ultralow-dose pediatric thoracic CT cases with an equal number of age-matched standard-dose chest CT cases also selected for retrospective analysis. Objective image quality (contrast-to-noise and signal-to-noise ratios) and radiation dose were assessed. Qualitative Likert scorings of the bone, lung, and soft tissues were performed by 2 expert radiologists. Electronic health records of the ultralow-dose cohort were reviewed for at least 1 year to evaluate for potentially missed thoracic pathology and symptoms. Variables were compared using parametric and nonparametric tests in R software 4.0.5.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The ultralow-dose protocol group had statistically significant reductions (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001) in the volume CT dose index (0.31 \u00b1 0.19 vs 2.20 \u00b1 1.64 mGy), effective radiation dose (0.14 \u00b1 0.08 vs 1.07 \u00b1 0.86 mSv), and size-specific dose estimates (0.50 \u00b1 0.30 vs 3.43 \u00b1 2.56 mGy) compared with the standard protocol, yielding an 86.51% and 85.32% reduction, respectively. The signal-to-noise ratio (20.49 \u00b1 6.19 vs 36.48 \u00b1 10.20), contrast-to-noise (21.65 \u00b1 6.57 vs 38.47 \u00b1 10.59), and subjective measures of image quality (lung parenchyma [3.07 \u00b1 0.92 vs 4.42 \u00b1 0.47], bony structures [3.30 \u00b1 0.86 vs 4.52 \u00b1 0.51], and surrounding soft tissues [2.57 \u00b1 0.63 vs 3.89 \u00b1 0.65]) were also significantly lower in the ultralow-dose protocol (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). No differences were seen in the number and size of pulmonary nodules between groups. Clinical and imaging follow of all 104 patients undergoing ultralow-dose CT demonstrated no evidence of missed thoracic pathology causing symptoms.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Ultralow-dose thoracic CT is an acceptable modality for imaging pediatric patients with pectus excavatum and other conditions primarily causing osseous pathology, with effective radiation dose comparable to plain radiographs and a moderate increase in image noise that did not significantly reduce its ability to detect incidental nonosseous thoracic pathology.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001285","type":"journal-article","created":{"date-parts":[[2022,5,12]],"date-time":"2022-05-12T19:01:23Z","timestamp":1652382083000},"page":"492-498","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Detection of Incidental Nonosseous Thoracic Pathology on State-of-the-Art Ultralow-Dose Protocol Computed Tomography in Pediatric Patients With Pectus Excavatum"],"prefix":"10.1097","volume":"46","author":[{"given":"Sebastian","family":"Gallo-Bernal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jesi","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristy","family":"Savage","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katherine","family":"Nimkin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael S.","family":"Gee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.2214\/AJR.14.13629","article-title":"Ultra-low-dose CT of the thorax using iterative reconstruction: evaluation of image quality and radiation dose reduction","volume":"204","year":"2015","journal-title":"Am J Roentgenol"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","article-title":"Estimated risks of radiation-induced fatal cancer from pediatric CT","volume":"176","year":"2001","journal-title":"Am J Roentgenol"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"2387","DOI":"10.1118\/1.1415074","article-title":"Estimates of the cancer risks from pediatric CT radiation are not merely theoretical: comment on \u201cpoint\/counterpoint: in x-ray computed tomography, technique factors should be selected appropriate to patient size. Against the proposition\u201d","volume":"28","year":"2001","journal-title":"Med Phys"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1007\/s00247-002-0671-1","article-title":"Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative","volume":"32","year":"2002","journal-title":"Pediatr Radiol"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1148\/rg.2019180082","article-title":"Advanced CT techniques for decreasing radiation dose, reducing sedation requirements, and optimizing image quality in children","volume":"39","year":"2019","journal-title":"Radiographics"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","article-title":"Strategies for reducing radiation dose in CT","volume":"47","year":"2009","journal-title":"Radiol Clin North Am"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1148\/rg.313105079","article-title":"Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls","volume":"31","year":"2011","journal-title":"Radiographics"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/HP.0000000000000997","article-title":"Computed tomography technology-and dose-in the 21st century","volume":"116","year":"2019","journal-title":"Health Phys"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1148\/rg.2018180041","article-title":"Radiation dose reduction at pediatric CT: use of low tube voltage and iterative reconstruction","volume":"38","year":"2018","journal-title":"Radiographics"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1001\/jamapediatrics.2013.311","article-title":"The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk","volume":"167","year":"2013","journal-title":"JAMA Pediatr"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1007\/s00247-015-3283-2","article-title":"Image Gently: toward optimizing the practice of pediatric CT through resources and dialogue","volume":"45","year":"2015","journal-title":"Pediatr Radiol"},{"issue":"suppl 2","key":"bib12-20250802","first-page":"461","article-title":"Image gently: progress and challenges in CT education and advocacy","volume":"41","year":"2011","journal-title":"Pediatr Radiol"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1148\/radiol.2231012100","article-title":"The ALARA concept in pediatric CT: myth or reality?","volume":"223","year":"2002","journal-title":"Radiology"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1016\/j.acra.2019.07.017","article-title":"Chest x-ray dose equivalent low-dose CT with tin filtration: potential role for the assessment of pectus excavatum","volume":"27","year":"2020","journal-title":"Acad Radiol"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s10140-017-1487-5","article-title":"Pediatric chest CT at chest radiograph doses: when is the ultralow-dose chest CT clinically appropriate?","volume":"24","year":"2017","journal-title":"Emerg Radiol"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1007\/s00247-014-2899-y","article-title":"Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction","volume":"44","year":"2014","journal-title":"Pediatr Radiol"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1097\/RLI.0b013e31827efc3a","article-title":"Model-based iterative reconstruction technique for ultralow-dose chest CT","volume":"48","year":"2013","journal-title":"Invest Radiol"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1053\/j.semtcvs.2009.03.001","article-title":"Anatomical, histologic, and genetic characteristics of congenital chest wall deformities","volume":"21","year":"2009","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1055\/s-0038-1668129","article-title":"Deformities of the thoracic wall: don't forget the plastic surgeon","volume":"28","year":"2018","journal-title":"Eur J Pediatr Surg"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1007\/s00268-008-9793-4","article-title":"912 open pectus excavatum repairs: changing trends, lessons learned: one surgeon's experience","volume":"33","year":"2009","journal-title":"World J Surg"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.jpeds.2011.01.065","article-title":"Increasing severity of pectus excavatum is associated with reduced pulmonary function","volume":"159","year":"2011","journal-title":"J Pediatr"},{"key":"bib22-20250802","first-page":"e403","article-title":"Pectus excavatum: more than a matter of aesthetics","volume":"45","year":"2016","journal-title":"Pediatr Ann"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1016\/S0022-3468(87)80585-7","article-title":"Use of CT scans in selection of patients for pectus excavatum surgery: a preliminary report","volume":"22","year":"1987","journal-title":"J Pediatr Surg"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1016\/j.jpedsurg.2006.12.070","article-title":"Clinical impact of optical imaging with 3-D reconstruction of torso topography in common anterior chest wall anomalies","volume":"42","year":"2007","journal-title":"J Pediatr Surg"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1016\/j.jpedsurg.2010.10.013","article-title":"Three-dimensional computed tomography for evaluation and management of children with complex chest wall anomalies: useful information or just pretty pictures?","volume":"46","year":"2011","journal-title":"J Pediatr Surg"},{"key":"bib26-20250802","article-title":"The Measurement, Reporting, and Management of Radiation Dose in CT","year":"2008"},{"key":"bib27-20250802","article-title":"Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations","year":"2011"},{"key":"bib28-20250802","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1148\/radiol.2481071451","article-title":"Effective doses in radiology and diagnostic nuclear medicine: a catalog","volume":"248","year":"2008","journal-title":"Radiology"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1053\/j.sult.2014.05.003","article-title":"Pectus excavatum: current imaging techniques and opportunities for dose reduction","volume":"35","year":"2014","journal-title":"Semin Ultrasound CT MR"},{"key":"bib30-20250802","first-page":"581","article-title":"Evaluation of kidney stones with reduced\u2013radiation dose CT: Progress from 2011\u20132012 to 2015\u20132016\u2014not there yet","volume":"286","year":"2018","journal-title":"Radiology"},{"key":"bib31-20250802","doi-asserted-by":"crossref","first-page":"396","DOI":"10.2214\/AJR.07.3414","article-title":"Diagnostic performance of low-dose CT for the detection of urolithiasis: a meta-analysis","volume":"191","year":"2008","journal-title":"Am J Roentgenol"},{"key":"bib32-20250802","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1097\/JU.0000000000000030","article-title":"Impact of the image gently\u00ae campaign on computerized tomography use for evaluation of pediatric nephrolithiasis","volume":"201","year":"2019","journal-title":"J Urol"},{"key":"bib33-20250802","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1016\/j.diii.2016.06.009","article-title":"Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image quality","volume":"97","year":"2016","journal-title":"Diagn Interv Imaging"},{"key":"bib34-20250802","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1097\/RLI.0000000000000093","article-title":"Very low-dose (0.15 mGy) chest CT protocols using the COPDGene 2 test object and a third-generation dual-source CT scanner with corresponding third-generation iterative reconstruction software","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib35-20250802","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1007\/s00330-012-2627-7","article-title":"Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest x-ray examination: preliminary observations","volume":"23","year":"2013","journal-title":"Eur Radiol"},{"key":"bib36-20250802","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1007\/s00330-013-3090-9","article-title":"Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction","volume":"24","year":"2014","journal-title":"Eur Radiol"},{"key":"bib37-20250802","doi-asserted-by":"crossref","first-page":"1444","DOI":"10.2214\/AJR.21.26183","article-title":"Comparison of 0.3-mSv CT to standard-dose ct for detection of lung nodules in children and young adults with cancer","volume":"217","year":"2021","journal-title":"AJR Am J Roentgenol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001285","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:18:42Z","timestamp":1754176722000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001285"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":37,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001285","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5]]}}}