{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T09:06:36Z","timestamp":1787821596292,"version":"build-2784847793"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:title>Objective<\/jats:title>\n          <jats:p>This work aimed to retrospectively evaluate the potential of dose reduction on chest computed tomography (CT) examinations by reducing the longitudinal scan length for patients positive for coronavirus disease 2019 (COVID-19).<\/jats:p>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This study used the Personalized Rapid Estimation of Dose in CT (PREDICT) tool to estimate patient-specific organ doses from CT image data. The PREDICT is a research tool that combines a linear Boltzmann transport equation solver for radiation dose map generation with deep learning algorithms for organ contouring. Computed tomography images from 74 subjects in the Medical Imaging Data Resource Center\u2013RSNA International COVID-19 Open Radiology Database data set (chest CT of adult patients positive for COVID-19), which included expert annotations including \u201cinfectious opacities,\u201d were analyzed. First, the full z-scan length of the CT image data set was evaluated. Next, the z-scan length was reduced from the left hemidiaphragm to the top of the aortic arch. Generic dose reduction based on dose length product (DLP) and patient-specific organ dose reductions were calculated. The percentage of infectious opacities excluded from the reduced z-scan length was used to quantify the effect on diagnostic utility.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Generic dose reduction, based on DLP, was 69%. The organ dose reduction ranged from approximately equal to 18% (breasts) to approximately equal to 64% (bone surface and bone marrow). On average, 12.4% of the infectious opacities were not included in the reduced z-coverage, per patient, of which 5.1% were above the top of the arch and 7.5% below the left hemidiaphragm.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Limiting z-scan length of chest CTs reduced radiation dose without significantly compromising diagnostic utility in COVID-19 patients. The PREDICT demonstrated that patient-specific organ dose reductions varied from generic dose reduction based on DLP.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001312","type":"journal-article","created":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T19:00:09Z","timestamp":1649703609000},"page":"576-583","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Reduced Chest Computed Tomography Scan Length for Patients Positive for Coronavirus Disease 2019: Dose Reduction and Impact on Diagnostic Utility"],"prefix":"10.1097","volume":"46","author":[{"given":"Sara","family":"Principi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stacy","family":"O'Connor","sequence":"additional","affiliation":[{"name":"Radiology Department, Medical College of Wisconsin, Milwaukee, WI."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luba","family":"Frank","sequence":"additional","affiliation":[{"name":"Radiology Department, Medical College of Wisconsin, Milwaukee, WI."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taly Gilat","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,4,8]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.chest.2020.04.003","article-title":"The role of chest imaging in patient management during the COVID-19 pandemic: a multinational consensus statement from the Fleischner Society","volume":"158","year":"2020","journal-title":"Chest"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"180076","DOI":"10.1183\/16000617.0076-2018","article-title":"Presentation, diagnosis and clinical course of the spectrum of progressive-fibrosing interstitial lung diseases","volume":"27","year":"2018","journal-title":"Eur Respir Rev"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"6554","DOI":"10.1007\/s00330-020-07034-x","article-title":"Chest CT practice and protocols for COVID-19 from radiation dose management perspective","volume":"30","year":"2020","journal-title":"Eur Radiol"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"1848","DOI":"10.1148\/rg.2020200159","article-title":"Chest CT in COVID-19: what the radiologist needs to know","volume":"40","year":"2020","journal-title":"RadioGraphics"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"E141","DOI":"10.1148\/radiol.2020203453","article-title":"Variations in CT utilization, protocols, and radiation doses in COVID-19 pneumonia: results from 28 countries in the IAEA study","volume":"298","year":"2021","journal-title":"Radiology"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","article-title":"Estimated risks of radiation-induced fatal cancer from pediatric CT","volume":"176","year":"2001","journal-title":"AJR Am J Roentgenol"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1542\/peds.2007-1910","article-title":"Radiation risk to children from computed tomography","volume":"120","year":"2007","journal-title":"Pediatrics"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1001\/jama.298.3.317","article-title":"Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography","volume":"298","year":"2007","journal-title":"JAMA"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography\u2014an increasing source of radiation exposure","volume":"357","year":"2007","journal-title":"N Engl J Med"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1007\/s10140-015-1340-7","article-title":"Reduced z-axis technique for CT pulmonary angiography in pregnancy\u2014validation for practical use and dose reduction","volume":"22","year":"2015","journal-title":"Emerg Radiol"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"E204","DOI":"10.1148\/radiol.2021203957","article-title":"The RSNA International COVID-19 Open Radiology Database (RICORD)","volume":"299","year":"2021","journal-title":"Radiology"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1007\/s10278-013-9622-7","article-title":"The Cancer Imaging Archive (TCIA): maintaining and operating a public information repository","volume":"26","year":"2013","journal-title":"J Digit Imaging"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"111920","DOI":"10.1118\/1.4824918","article-title":"Dose equations for tube current modulation in CT scanning and the interpretation of the associated CTDIvol","volume":"40","year":"2013","journal-title":"Med Phys"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"6572","DOI":"10.1118\/1.4933197","article-title":"Technical note: phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique","volume":"42","year":"2015","journal-title":"Med Phys"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1002\/mp.13305","article-title":"A fast, linear Boltzmann transport equation solver for computed tomography dose calculation (Acuros CTD)","volume":"46","year":"2019","journal-title":"Med Phys"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"6470","DOI":"10.1002\/mp.14494","article-title":"Deterministic linear Boltzmann transport equation solver for patient-specific CT dose estimation: comparison against a Monte Carlo benchmark for realistic scanner configurations and patient models","volume":"47","year":"2020","journal-title":"Med Phys"},{"key":"bib19-20250802","first-page":"1","article-title":"Pediatric chest-abdomen-pelvis and abdomen-pelvis CT images with expert contours","year":"2022","journal-title":"Med Phys"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"8075","DOI":"10.1002\/mp.15301","article-title":"Validation of a deterministic linear Boltzmann transport equation solver for rapid CT dose computation using physical dose measurements in pediatric phantoms","volume":"48","year":"2021","journal-title":"Med Phys"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1097\/RCT.0b013e318198cd18","article-title":"Dose reduction in computed tomographic angiography of pregnant patients with suspected acute pulmonary embolism","volume":"33","year":"2009","journal-title":"J Comput Assist Tomogr"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1007\/s11547-020-01237-4","article-title":"Chest CT features of coronavirus disease 2019 (COVID-19) pneumonia: key points for radiologists","volume":"125","year":"2020","journal-title":"Radiol Med"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"e209004","DOI":"10.1148\/ryct.2020209004","article-title":"Extension of coronavirus disease 2019 on chest CT and implications for chest radiographic interpretation","volume":"2","year":"2020","journal-title":"Radiol Cardiothorac Imaging"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"E204","DOI":"10.1148\/radiol.2021203957","article-title":"The RSNA International COVID-19 Open Radiology Database (RICORD)","volume":"299","year":"2021","journal-title":"Radiology"},{"key":"bib26-20250802","doi-asserted-by":"crossref","first-page":"4568","DOI":"10.1002\/mp.13141","article-title":"Autosegmentation for thoracic radiation treatment planning: a grand challenge at AAPM 2017","volume":"45","year":"2018","journal-title":"Med Phys"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1002\/acm2.12505","article-title":"Organ doses evaluation for chest computed tomography procedures with TL dosimeters: comparison with Monte Carlo simulations","volume":"20","year":"2019","journal-title":"J Appl Clin Med Phys"},{"key":"bib30-20250802","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1118\/1.3298015","article-title":"Organ doses to adult patients for chest CT","volume":"37","year":"2010","journal-title":"Med Phys"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001312","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:17:13Z","timestamp":1754176633000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001312"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,8]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001312","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4,8]]}}}