{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T01:27:26Z","timestamp":1773365246508,"version":"3.50.1"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>Computed tomography pulmonary angiogram (CTPA) is important to evaluate suspected pulmonary embolism in pregnancy but has maternal\/fetal radiation risks. The objective of this study was to estimate maternal and fetal radiation-induced cancer risk from CTPA during pregnancy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Simulation modeling via the National Cancer Institute's Radiation Risk Assessment Tool was used to estimate excess cancer risks from 17 organ doses from CTPA during pregnancy, with doses determined by a radiation dose indexing monitoring system. Organ doses were obtained from a radiation dose indexing monitoring system. Maternal and fetal cancer risks per 100,000 were calculated for male and female fetuses and several maternal ages.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The 534 CTPA examinations had top 3 maternal organ doses to the breast, lung, and stomach of 17.34, 15.53, and 9.43 mSv, respectively, with a mean uterine dose of 0.21 mSv. The total maternal excess risks of developing cancer per 100,000 were 181, 151, 121, 107, 94.5, 84, and 74.4, respectively, for a 20-, 25-, 30-, 35-, 40-, 45-, and 50-year-old woman undergoing CTPA, compared with baseline cancer risks of 41,408 for 20-year-old patients. The total fetal excess risks of developing cancer per 100,000 were 12.3 and 7.3 for female and male fetuses, respectively, when compared with baseline cancer risks of 41,227 and 48,291.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Discussion<\/jats:title>\n            <jats:p>Excess risk of developing cancer from CTPA was small relative to baseline cancer risk for pregnant patients and fetuses, decreased for pregnant patients with increasing maternal age, and was greater for female fetuses than male fetuses.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001545","type":"journal-article","created":{"date-parts":[[2024,1,25]],"date-time":"2024-01-25T15:00:08Z","timestamp":1706194808000},"page":"257-262","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Maternal and Fetal Radiation-Induced Cancer Risk From Computed Tomography Pulmonary Angiography During Pregnancy: A Retrospective Cohort Study Across a Multihospital Integrated Health Care Network"],"prefix":"10.1097","volume":"48","author":[{"given":"Stuart L.","family":"Cohen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chinara","family":"Feizullayeva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason J.","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicholas","family":"Chan","sequence":"additional","affiliation":[{"name":"Department of Medicine, Cleveland Clinic, Cleveland, OH"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John Austin","family":"McCandlish","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul P.","family":"Cronin","sequence":"additional","affiliation":[{"name":"Department of Radiology and Imaging Science, Emory University Hospital, Atlanta, GA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew A.","family":"Barish","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, North Shore University Hospital\/Northwell Health, Manhasset, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William","family":"O'Connell","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, North Shore University Hospital\/Northwell Health, Manhasset, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pina C.","family":"Sanelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,1,16]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1001\/archinte.1991.00400050081016","article-title":"A population-based perspective of the hospital incidence and case-fatality rates of deep vein thrombosis and pulmonary embolism. The Worcester DVT study","volume":"151","year":"1991","journal-title":"Arch Intern Med"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1016\/j.ajog.2005.11.008","article-title":"Venous thromboembolism during pregnancy and the postpartum period: incidence, risk factors, and mortality","volume":"194","year":"2006","journal-title":"Am J Obstet Gynecol"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1111\/j.1538-7836.2010.03794.x","article-title":"Incidence and risk factors for pulmonary embolism in the postpartum period","volume":"8","year":"2010","journal-title":"J Thromb Haemost"},{"issue":"23 Suppl 1","key":"bib4-20250802","first-page":"I4","article-title":"The epidemiology of venous thromboembolism","volume":"107","year":"2003","journal-title":"Circulation"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1053\/j.semperi.2019.03.004","article-title":"Venous thromboembolism as a cause of severe maternal morbidity and mortality in the United States","volume":"43","year":"2019","journal-title":"Semin Perinatol"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1056\/NEJMoa1813865","article-title":"Pregnancy-adapted YEARS algorithm for diagnosis of suspected pulmonary embolism","volume":"380","year":"2019","journal-title":"N Engl J Med"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"766","DOI":"10.7326\/M18-1670","article-title":"Diagnosis of pulmonary embolism during pregnancy: a multicenter prospective management outcome study","volume":"169","year":"2018","journal-title":"Ann Intern Med"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"785","DOI":"10.2214\/AJR.11.8223","article-title":"Imaging of pregnant and lactating patients: part 2, evidence-based review and recommendations","volume":"198","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"176","DOI":"10.3324\/haematol.2018.196121","article-title":"Computed tomography pulmonary angiography versus ventilation-perfusion lung scanning for diagnosing pulmonary embolism during pregnancy: a systematic review and meta-analysis","volume":"104","year":"2019","journal-title":"Haematologica"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.2967\/jnumed.114.137968","article-title":"Perfusion scintigraphy versus 256-slice CT angiography in pregnant patients suspected of pulmonary embolism: comparison of radiation risks","volume":"55","year":"2014","journal-title":"J Nucl Med"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"108721","DOI":"10.1016\/j.ejrad.2019.108721","article-title":"Predictors of radiation dose for CT pulmonary angiography in pregnancy across a multihospital integrated healthcare network","volume":"121","year":"2019","journal-title":"Eur J Radiol"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1007\/s10140-019-01728-6","article-title":"Evaluation of CTPA interpreted as limited in pregnant patients suspected for pulmonary embolism","volume":"27","year":"2020","journal-title":"Emerg Radiol"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.ejro.2016.04.003","article-title":"Comparison of organ-specific-radiation dose levels between 70 kVp perfusion CT and standard tri-phasic liver CT in patients with hepatocellular carcinoma using a Monte-Carlo-simulation\u2013based analysis platform","volume":"3","year":"2016","journal-title":"Eur J Radiol Open"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1148\/radiol.2015142728","article-title":"Radiation doses in consecutive CT examinations from five University of California Medical centers","volume":"277","year":"2015","journal-title":"Radiology"},{"issue":"2\u20134","key":"bib16-20250802","first-page":"1","article-title":"The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103","volume":"37","year":"2007","journal-title":"Ann ICRP"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1177\/0284185117716199","article-title":"Verification of organ doses calculated by a dose monitoring software tool based on Monte Carlo simulation in thoracic CT protocols","volume":"59","year":"2018","journal-title":"Acta Radiol"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1088\/0952-4746\/32\/3\/205","article-title":"RadRAT: a radiation risk assessment tool for lifetime cancer risk projection","volume":"32","year":"2012","journal-title":"J Radiol Prot"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1161\/STROKEAHA.118.022454","article-title":"Risk of radiation-induced cancer from computed tomography angiography use in imaging surveillance for unruptured cerebral aneurysms","volume":"50","year":"2019","journal-title":"Stroke"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1097\/MNM.0000000000000114","article-title":"Detection of pulmonary embolism during pregnancy: comparing radiation doses of CTPA and pulmonary scintigraphy","volume":"35","year":"2014","journal-title":"Nucl Med Commun"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.thromres.2019.03.007","article-title":"The OPTICA study (Optimised Computed Tomography Pulmonary Angiography in Pregnancy Quality and Safety study): rationale and design of a prospective trial assessing the quality and safety of an optimised CTPA protocol in pregnancy","volume":"177","year":"2019","journal-title":"Thromb Res"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1148\/radiol.11114045","article-title":"American Thoracic Society documents: an official American Thoracic Society\/Society of Thoracic Radiology Clinical Practice Guideline\u2014evaluation of suspected pulmonary embolism in pregnancy","volume":"262","year":"2012","journal-title":"Radiology"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1111\/jth.13980","article-title":"Risk of early-onset breast cancer among women exposed to thoracic computed tomography in pregnancy or early postpartum","volume":"16","year":"2018","journal-title":"J Thromb Haemost"},{"key":"bib25-20250802","first-page":"1347","article-title":"Malignant breast tumors among atomic bomb survivors, Hiroshima and Nagasaki, 1950-74","volume":"62","year":"1979","journal-title":"J Natl Cancer Inst"},{"key":"bib26-20250802","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/HP.0000000000001157","article-title":"Position Statement of the Health Physics Society PS010-4: Radiation Risk in Perspective","volume":"118","year":"2020","journal-title":"Health Phys"},{"key":"bib27-20250802","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1667\/RR13829.1","article-title":"Estimating risk of low radiation doses \u2014 a critical review of the BEIR VII report and its use of the linear no-threshold (LNT) hypothesis","volume":"182","year":"2014","journal-title":"Radiat Res"},{"key":"bib28-20250802","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1080\/09553002.2017.1328750","article-title":"The linear nonthreshold (LNT) model as used in radiation protection: an NCRP update","volume":"93","year":"2017","journal-title":"Int J Radiat Biol"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1097\/HP.0000000000001015","article-title":"Recent epidemiologic studies and the linear no-threshold model for radiation protection-considerations regarding NCRP commentary 27","volume":"116","year":"2019","journal-title":"Health Phys"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001545","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:14:51Z","timestamp":1754176491000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001545"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,16]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001545","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1,16]]}}}