{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:40:03Z","timestamp":1754178003287,"version":"3.41.2"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2024,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>We describe early ex vivo proof-of-concept testing of a novel system composed of a disposable endorectal coil and converging multichannel needle guide with a reusable clamp stand, embedded electronics, and baseplate to allow for endorectal magnetic resonance (MR) imaging and in-bore MRI-targeted biopsy of the prostate as a single integrated procedure. Using prostate phantoms imaged with standard T<jats:sub>2<\/jats:sub>-weighted sequences in a Siemens 3T Prisma MR scanner, we measured the signal-to-noise ratio in successive 1-cm distances from the novel coil and from a commercially available inflatable balloon coil and measured the lateral and longitudinal deviation of the tip of a deployed MR compatible needle from the intended target point. Signal-to-noise ratio obtained with the novel system was significantly better than the inflatable balloon coil at each of five 1-cm intervals, with a mean improvement of 78% (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05). In a representative sampling of 15 guidance channels, the mean lateral deviation for MR imaging\u2013guided needle positioning was 1.7 mm and the mean longitudinal deviation was 2.0 mm. Our ex vivo results suggest that our novel system provides significantly improved signal-to-noise ratio when compared with an inflatable balloon coil and is capable of accurate MRI-guided needle deployment.<\/jats:p>","DOI":"10.1097\/rct.0000000000001583","type":"journal-article","created":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T02:02:16Z","timestamp":1705024936000},"page":"378-381","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Prototype Description and Ex Vivo Evaluation of a System for Combined Endorectal Magnetic Resonance Imaging and In-Bore Biopsy of the Prostate"],"prefix":"10.1097","volume":"48","author":[{"given":"Fergus V.","family":"Coakley","sequence":"first","affiliation":[{"name":"Department of Diagnostic Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bryan R.","family":"Foster","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David W.","family":"Schroeder","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William D.","family":"Rooney","sequence":"additional","affiliation":[{"name":"Advanced Imaging Research Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Randall W.","family":"Jones","sequence":"additional","affiliation":[{"name":"ScanMed LLC, Omaha, NE."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher L.","family":"Amling","sequence":"additional","affiliation":[{"name":"Department of Urology, Oregon Health and Science University, Portland, OR"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,1,12]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/S0140-6736(16)32401-1","article-title":"Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study","volume":"389","year":"2017","journal-title":"Lancet"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"1767","DOI":"10.1056\/NEJMoa1801993","article-title":"MRI-targeted or standard biopsy for prostate-cancer diagnosis","volume":"378","year":"2018","journal-title":"N Engl J Med"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1056\/NEJMoa2100852","article-title":"MRI-targeted or standard biopsy in prostate cancer screening","volume":"385","year":"2021","journal-title":"N Engl J Med"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1097\/JU.0000000000001406","article-title":"Application of the PRECISION trial biopsy strategy to a contemporary magnetic resonance imaging-targeted biopsy cohort\u2014how many clinically significant prostate cancers are missed?","volume":"205","year":"2021","journal-title":"J Urol"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1097\/JU.0000000000000617","article-title":"Update of the standard operating procedure on the use of multiparametric magnetic resonance imaging for the diagnosis, staging and management of prostate cancer","volume":"203","year":"2020","journal-title":"J Urol"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1016\/j.annonc.2020.06.011","article-title":"Prostate cancer: ESMO clinical practice guidelines for diagnosis, treatment and follow-up","volume":"31","year":"2020","journal-title":"Ann Oncol"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jacr.2013.05.006","article-title":"Prostate MRI: access to and current practice of prostate MRI in the United States","volume":"11","year":"2014","journal-title":"J Am Coll Radiol"},{"key":"bib8-20250802","first-page":"569","article-title":"Prostate MRI: is endorectal coil necessary?\u2014A review","volume":"12","year":"2022","journal-title":"Life (Basel)"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1002\/jmri.21331","article-title":"A clinical comparison of rigid and inflatable endorectal-coil probes for MRI and 3D MR spectroscopic imaging (MRSI) of the prostate","volume":"27","year":"2008","journal-title":"J Magn Reson Imaging"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1002\/jmri.24317","article-title":"Comparison of endorectal coil and nonendorectal coil T2W and diffusion-weighted MRI at 3 Tesla for localizing prostate cancer: correlation with whole-mount histopathology","volume":"39","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.euo.2018.08.022","article-title":"Magnetic resonance imaging\u2013guided in-bore and magnetic resonance imaging-transrectal ultrasound fusion targeted prostate biopsies: an adjusted comparison of clinically significant prostate cancer detection rate","volume":"2","year":"2019","journal-title":"Eur Urol Oncol"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.2214\/AJR.20.25207","article-title":"In-bore versus fusion MRI-targeted biopsy of PI-RADS category 4 and 5 lesions: a retrospective comparative analysis using propensity score weighting","volume":"217","year":"2021","journal-title":"AJR Am J Roentgenol"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"3362","DOI":"10.1007\/s00330-016-4706-7","article-title":"Everyman's prostate phantom: kiwi-fruit substitute for human prostates at magnetic resonance imaging, diffusion-weighted imaging and magnetic resonance spectroscopy","volume":"27","year":"2017","journal-title":"Eur Radiol"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1002\/jmri.20969","article-title":"Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters","volume":"26","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"bib15-20250802","first-page":"383","article-title":"MRI-guided robotic prostate biopsy: a clinical accuracy validation","volume":"13","year":"2010","journal-title":"Med Image Comput Comput Assist Interv"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1016\/j.eururo.2012.01.047","article-title":"Three-tesla magnetic resonance-guided prostate biopsy in men with increased prostate-specific antigen and repeated, negative, random, systematic, transrectal ultrasound biopsies: detection of clinically significant prostate cancers","volume":"62","year":"2012","journal-title":"Eur Urol"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"215","DOI":"10.5152\/dir.2014.14372","article-title":"MRI-guided core needle biopsy of the prostate: acceptance and side effects","volume":"21","year":"2015","journal-title":"Diagn Interv Radiol"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1007\/s00261-016-0750-7","article-title":"In-bore magnetic resonance-guided transrectal biopsy for the detection of clinically significant prostate cancer","volume":"41","year":"2016","journal-title":"Abdom Radiol (NY)"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1111\/j.1464-410X.2012.11657.x","article-title":"Outcomes of transperineal template-guided prostate biopsy in 409 patients","volume":"112","year":"2013","journal-title":"BJU Int"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1016\/j.ijrobp.2004.01.045","article-title":"Acute urinary retention after transperineal template-guided prostate biopsy","volume":"59","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/j.clinimag.2016.01.011","article-title":"Endorectal multiparametric MRI of the prostate: incremental effect of perfusion imaging on biopsy target identification","volume":"40","year":"2016","journal-title":"Clin Imaging"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1089\/sur.2015.040","article-title":"Prophylactic antibiotics in prostate biopsy: a meta-analysis based on randomized controlled trials","volume":"16","year":"2015","journal-title":"Surg Infect (Larchmt)"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"3839","DOI":"10.3390\/cancers15153839","article-title":"Advancements in MRI-based radiomics and artificial intelligence for prostate cancer: a comprehensive review and future prospects","volume":"15","year":"2023","journal-title":"Cancers (Basel)"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s00345-015-1620-6","article-title":"Real-time cancer diagnosis during prostate biopsy: ex vivo evaluation of full-field optical coherence tomography (FFOCT) imaging on biopsy cores","volume":"34","year":"2016","journal-title":"World J Urol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001583","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:13:04Z","timestamp":1754176384000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001583"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,12]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001583","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"type":"electronic","value":"1532-3145"},{"type":"print","value":"0363-8715"}],"subject":[],"published":{"date-parts":[[2024,1,12]]}}}