{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:40:04Z","timestamp":1754178004320,"version":"3.41.2"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>This study aimed to investigate whether virtual monoenergetic images (VMIs) can aid radiologists and surgeons in better identifying the arc of Riolan (AOR) and to determine the optimal kilo electron volt (keV) level.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Thirty-three patients were included. Conventional images (CIs) and VMI (40\u2013100 keV) were reconstructed using arterial phase spectral-based images. The computed tomography (CT) attenuation and noise of the AOR, the CT attenuation of the erector spinal muscle, and the background noise on VMI and CI were measured, respectively. The signal-to-noise ratio, contrast-to-noise ratio (CNR), and signal intensity ratio were calculated. The image quality of the AOR was evaluated according to a 4-point Likert grade.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The CT attenuation, noise, CNR, and signal intensity ratio of the AOR were significantly higher in VMI at 40 and 50 keV compared with CI (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001); VMI at 40 keV was significantly higher than 50 keV (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05). No significant difference in signal-to-noise ratio, background noise, and CT attenuation of the spinal erector muscle was observed between VMI and CI (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; 0.05). virtual monoenergetic image at 40 keV produced the best subjective scores.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Virtual monoenergetic image at 40 keV makes it easier to observe the AOR with optimized subjective and objective image quality. This may prompt radiologists and surgeons to actively search for it and encourage surgeons to preserve it during splenic flexure takedown.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001586","type":"journal-article","created":{"date-parts":[[2024,2,12]],"date-time":"2024-02-12T21:01:37Z","timestamp":1707771697000},"page":"640-646","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Virtual Monoenergetic Images Facilitate Better Identification of the Arc of Riolan During Splenic Flexure Takedown"],"prefix":"10.1097","volume":"48","author":[{"given":"Qian","family":"Li","sequence":"first","affiliation":[{"name":"Departments of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pengfei","family":"Zhang","sequence":"additional","affiliation":[{"name":"Gastrointestinal Surgery, The Third Hospital of Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ranxu","family":"Zhang","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianfeng","family":"Zhang","sequence":"additional","affiliation":[{"name":"The Second Department of General Surgery, The Fourth Hospital of Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruoxi","family":"Tian","sequence":"additional","affiliation":[{"name":"Gastrointestinal Surgery, The Third Hospital of Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianyi","family":"Gao","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery, The Third Hospital of Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Huang","sequence":"additional","affiliation":[{"name":"Gastrointestinal Surgery, The Third Hospital of Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ping","family":"Zhang","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Wei","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rui","family":"Hong","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guiying","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of General Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Zhao","sequence":"additional","affiliation":[{"name":"Departments of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,2,9]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.21037\/jgo.2019.07.07","article-title":"Management of anastomotic leakage after rectal surgery: a review article","volume":"10","year":"2019","journal-title":"J Gastrointest Oncol"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1111\/codi.15435","article-title":"Treatment of anastomotic leakage after rectal cancer resection: the TENTACLE\u2013Rectum study","volume":"23","year":"2021","journal-title":"Colorectal Dis"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1186\/s12876-020-01462-1","article-title":"Analysis of risk factors for anastomotic leakage after lower rectal cancer resection, including drain type: a retrospective single-center study","volume":"20","year":"2020","journal-title":"BMC Gastroenterol"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1111\/codi.15997","article-title":"Risk factors for anastomotic leakage after anterior resection for rectal cancer (RALAR study): a nationwide retrospective study of the Italian Society of Surgical Oncology Colorectal Cancer Network Collaborative Group","volume":"24","year":"2022","journal-title":"Colorectal Dis"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1007\/s00384-018-2970-5","article-title":"Nomogram for predicting anastomotic leakage after low anterior resection for rectal cancer","volume":"33","year":"2018","journal-title":"Int J Colorectal Dis"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1007\/s11596-022-2616-2","article-title":"Risk factors of anastomotic leakage after anterior resection for rectal cancer patients","volume":"42","year":"2022","journal-title":"Curr Med Sci"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1097\/DCR.0000000000000995","article-title":"Arc of riolan-preserving splenic flexure takedown during anterior resection: potentially critical to prevent acute anastomotic ischemia","volume":"61","year":"2018","journal-title":"Dis Colon Rectum"},{"issue":"7\u20138","key":"bib8-20250802","first-page":"576","article-title":"Marginal artery stump pressure in left colic artery-preserving rectal cancer surgery: a clinical trial","volume":"87","year":"2017","journal-title":"ANZ J Surg"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"77","DOI":"10.2214\/ajr.126.1.77","article-title":"Griffiths' point: critical anastomosis at the splenic flexure. Significance in ischemia of the colon","volume":"126","year":"1976","journal-title":"Am J Roentgenol"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"641290","DOI":"10.3389\/fphys.2021.641290","article-title":"The new concept of physiological \u201cRiolan's arch\u201d and the reconstruction mechanism of pathological Riolan's arch after high ligation of the inferior mesenteric artery by CT angiography-based small vessel imaging","volume":"12","year":"2021","journal-title":"Front Physiol"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1007\/s00384-008-0465-5","article-title":"The oncologic benefit of high ligation of the inferior mesenteric artery in the surgical treatment of rectal or sigmoid colon cancer","volume":"23","year":"2008","journal-title":"Int J Colorectal Dis"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1001\/archsurg.140.12.1225","article-title":"Anastomosis of Riolan revisited: the meandering mesenteric artery","volume":"140","year":"2005","journal-title":"Arch Surg"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.radcr.2022.10.096","article-title":"Successful coil embolization of a ruptured aneurysm of the arc of Riolan artery","volume":"18","year":"2023","journal-title":"Radiol Case Rep"},{"key":"bib14-20250802","first-page":"66","article-title":"A rare case of aneurysm of arc of Riolan artery and gastroduodenal artery","volume":"4","year":"2014","journal-title":"J Clin Imaging Sci"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1007\/s00276-022-02992-x","article-title":"3D mesenteric angiogram-based assessment of arc of Riolan crossing the inferior mesenteric vein: important considerations in high ligation during splenic flexure takedown in anterior resection","volume":"44","year":"2022","journal-title":"Surg Radiol Anat"},{"key":"bib16-20250802","first-page":"1007","article-title":"Prevention of anastomotic fistula formation after low-position Dixon operation","volume":"30","year":"2014","journal-title":"Pak J Med Sci"},{"key":"bib17-20250802","first-page":"736","article-title":"Anastomotic vessels between superior mesenteric artery and inferior mesenteric artery: controversies and advances","volume":"60","year":"2022","journal-title":"Zhonghua Wai Ke Za Zhi"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1148\/radiol.2021203851","article-title":"CT angiography of the arc of Riolan","volume":"300","year":"2021","journal-title":"Radiology"},{"key":"bib19-20250802","first-page":"1251","article-title":"Venae comitante of the arc of Riolan","volume":"92","year":"2021","journal-title":"ANZ J Surg"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1097\/RCT.0000000000000743","article-title":"Spectral detector computed tomography pulmonary angiography: improved diagnostic assessment and automated estimation of window settings angiography of pulmonary arteries from novel spectral detector computed tomography provides improved image quality if settings are adjusted","volume":"42","year":"2018","journal-title":"J Comput Assist Tomogr"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1148\/rg.332125124","article-title":"Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT","volume":"33","year":"2013","journal-title":"Radiographics"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1097\/RCT.0000000000000748","article-title":"Evaluation of virtual monoenergetic images on pulmonary vasculature using the dual-layer detector-based spectral computed tomography","volume":"42","year":"2018","journal-title":"J Comput Assist Tomogr"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1148\/radiol.11110648","article-title":"Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography\u2014a prospective randomized trial","volume":"262","year":"2012","journal-title":"Radiology"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ejrad.2017.01.002","article-title":"Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses","volume":"88","year":"2017","journal-title":"Eur J Radiol"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1007\/s13244-017-0571-4","article-title":"Detector-based spectral CT with a novel dual-layer technology: principles and applications","volume":"8","year":"2017","journal-title":"Insights Imaging"},{"key":"bib26-20250802","doi-asserted-by":"crossref","first-page":"110160","DOI":"10.1016\/j.ejrad.2022.110160","article-title":"Comparative study of the image quality of twin beam dual energy and single energy carotid CT angiography","volume":"148","year":"2022","journal-title":"Eur J Radiol"},{"key":"bib27-20250802","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1016\/j.ejrad.2011.02.063","article-title":"Improving image quality in portal venography with spectral CT imaging","volume":"81","year":"2012","journal-title":"Eur J Radiol"},{"key":"bib28-20250802","first-page":"638","article-title":"A preliminary study of improving quality of CT angiography on small feeding arteries of abdominal tumors with optimizing gemstone spectral imaging technique using single source dual-energy CT","year":"2013","journal-title":"Chin J Radiol"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"e574","DOI":"10.1016\/j.ejrad.2013.04.040","article-title":"Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging","volume":"82","year":"2013","journal-title":"Eur J Radiol"},{"key":"bib30-20250802","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ejrad.2017.11.005","article-title":"Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner","volume":"98","year":"2018","journal-title":"Eur J Radiol"},{"key":"bib31-20250802","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1007\/s00330-019-06337-y","article-title":"Dual-layer spectral CT improves image quality of multiphasic pancreas CT in patients with pancreatic ductal adenocarcinoma","volume":"30","year":"2020","journal-title":"Eur Radiol"},{"key":"bib32-20250802","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1007\/s00330-015-3970-2","article-title":"Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast","volume":"26","year":"2016","journal-title":"Eur Radiol"},{"key":"bib33-20250802","first-page":"373","article-title":"Imaging anatomy of Riolan's arch in patients with isolated superior mesenteric artery dissection based on CT angiography","volume":"27","year":"2022","journal-title":"Chin J Anat Clin"},{"key":"bib34-20250802","first-page":"56","article-title":"Dual-energy CT with virtual monoenergetic images in demonstration of peripancreatic vessels: comparison with polyenergetic images","volume":"28","year":"2022","journal-title":"Chin Comput Med Imaging"},{"key":"bib35-20250802","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/RCT.0000000000000711","article-title":"Virtual monoenergetic images from a novel dual-layer spectral detector computed tomography scanner in portal venous phase: adjusted window settings depending on assessment focus are essential for image interpretation","volume":"42","year":"2018","journal-title":"J Comput Assist Tomogr"},{"key":"bib36-20250802","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.ejrad.2013.11.005","article-title":"Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography","volume":"83","year":"2014","journal-title":"Eur J Radiol"},{"key":"bib37-20250802","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/j.ejmp.2018.04.388","article-title":"Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: comparison with conventional tube-voltage images","volume":"49","year":"2018","journal-title":"Phys Med"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001586","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:13:09Z","timestamp":1754176389000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001586"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,9]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001586","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"type":"electronic","value":"1532-3145"},{"type":"print","value":"0363-8715"}],"subject":[],"published":{"date-parts":[[2024,2,9]]}}}