{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:40:06Z","timestamp":1754178006159,"version":"3.41.2"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (&gt;280 Hounsfield units (HU)) or unacceptable (&lt;279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann\u2013Whitney <jats:italic toggle=\"yes\">U<\/jats:italic> test to compare patient characteristics and assess the interpatient variability of subjects in both groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Group A received 56.2 mL CM and 2.6 mL\/s of injection, whereas group B received 76.9 mL CM and 3.4 mL\/s of injection (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.46). The acceptable (&gt;280 HU) and unacceptable (&lt;280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.71).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001603","type":"journal-article","created":{"date-parts":[[2024,4,10]],"date-time":"2024-04-10T04:03:09Z","timestamp":1712721789000},"page":"759-762","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation\u2014Computed Tomography Angiography in Patients With Aortic Stenosis"],"prefix":"10.1097","volume":"48","author":[{"given":"Takanori","family":"Masuda","sequence":"first","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Nakaura","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toru","family":"Higaki","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinori","family":"Funama","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoriaki","family":"Matsumoto","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoyasu","family":"Sato","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Tsuchiya General Hospital, Naka-ku, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomokazu","family":"Okimoto","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Internal Medicine, Edogawa Hospital, Tokyo, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keiko","family":"Arao","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiromasa","family":"Imaizumi","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichi","family":"Arao","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsushi","family":"Ono","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junichi","family":"Hiratsuka","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuo","family":"Awai","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,4,8]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"3143","DOI":"10.1093\/eurheartj\/ehz275","article-title":"Transcatheter aortic valve implantation vs surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis","volume":"40","year":"2019","journal-title":"Eur Heart J"},{"key":"bib2-20250802","first-page":"314","article-title":"Transcatheter aortic valve implantation (TAVI) in 2018: recent advances and future development","volume":"66","year":"2018","journal-title":"Minerva Cardioangiol"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.ejim.2018.07.002","article-title":"Transcatheter aortic valve implantation: update in 2018","volume":"55","year":"2018","journal-title":"Eur J Intern Med"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jcmg.2018.12.003","article-title":"Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)\/Transcatheter aortic valve replacement (TAVR): an expert consensus document of the Society of Cardiovascular Computed Tomography","volume":"12","year":"2019","journal-title":"J Am Coll Cardiol Img"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1007\/s10554-015-0793-9","article-title":"Automatic aortic root landmark detection in CTA images for preprocedural planning of transcatheter aortic valve implantation","volume":"32","year":"2016","journal-title":"Int J Card Imaging"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"73.e1","DOI":"10.1016\/j.crad.2019.11.015","article-title":"CT in planning transcatheter aortic valve implantation procedures and risk assessment","volume":"76","year":"2021","journal-title":"Clin Radiol"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1007\/s00330-021-08095-2","article-title":"DEtection of ProxImal coronary stenosis in the work-up for Transcatheter aortic valve implantation using CTA (from the DEPICT CTA collaboration)","volume":"32","year":"2022","journal-title":"Eur Radiol"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"273","DOI":"10.47102\/annals-acadmedsg.2019241","article-title":"Impact of chronic kidney disease on outcomes in transcatheter aortic valve implantation","volume":"49","year":"2020","journal-title":"Ann Acad Med Singap"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"W260","DOI":"10.2214\/AJR.10.5814","article-title":"Cardiothoracic CT angiography: current contrast medium delivery strategies","volume":"196","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"2426","DOI":"10.1007\/s00330-015-4080-x","article-title":"Low contrast media volume in pre-TAVI CT examinations","volume":"26","year":"2016","journal-title":"Eur Radiol"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.rcl.2009.08.012","article-title":"Optimization of contrast enhancement in thoracic MDCT","volume":"48","year":"2010","journal-title":"Radiol Clin North Am"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1007\/s11604-007-0138-2","article-title":"Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT","volume":"25","year":"2007","journal-title":"Radiat Med"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1148\/radiology.195.2.7724752","article-title":"Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement","volume":"195","year":"1995","journal-title":"Radiology"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"1446","DOI":"10.1007\/s00380-022-02024-z","article-title":"Usefulness of the patient-specific contrast enhancement optimizer simulation software during the whole-body computed tomography angiography","volume":"37","year":"2022","journal-title":"Heart Vessel"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"2998","DOI":"10.1007\/s00330-018-5823-2","article-title":"Minimizing individual variations in arterial enhancement on coronary CT angiographs using \"contrast enhancement optimizer\": a prospective randomized single-center study","volume":"29","year":"2019","journal-title":"Eur Radiol"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1097\/RCT.0000000000001000","article-title":"Individual optimization of contrast media injection protocol at hepatic dynamic computed tomography using patient-specific contrast enhancement optimizer","volume":"44","year":"2020","journal-title":"J Comput Assist Tomogr"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1148\/radiology.207.3.9609886","article-title":"Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model","volume":"207","year":"1998","journal-title":"Radiology"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1148\/radiology.207.3.9609887","article-title":"Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model","volume":"207","year":"1998","journal-title":"Radiology"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1148\/radiology.206.2.9457200","article-title":"Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate\u2014pharmacokinetic analysis and experimental porcine model","volume":"206","year":"1998","journal-title":"Radiology"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"e0191347","DOI":"10.1371\/journal.pone.0191347","article-title":"Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: analysis using computer simulation","volume":"13","year":"2018","journal-title":"PLoS One"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1186\/s13054-014-0603-0","article-title":"Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study","volume":"18","year":"2014","journal-title":"Crit Care"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1038\/jp.2016.2","article-title":"Hemodynamic reference for neonates of different age and weight: a pilot study with electrical cardiometry","volume":"36","year":"2016","journal-title":"J Perinatol: official journal of the California Perinatal Association"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1016\/j.jcmg.2021.01.026","article-title":"Low-flow aortic stenosis: flow rate does not replace but could refine stroke volume index","volume":"14","year":"2021","journal-title":"J Am Coll Cardiol Img"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/j.ihj.2014.10.423","article-title":"Low flow low gradient aortic stenosis: clinical pathways","volume":"66","year":"2014","journal-title":"Indian Heart J"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1148\/radiol.10090908","article-title":"Intravenous contrast medium administration and scan timing at CT: considerations and approaches","volume":"256","year":"2010","journal-title":"Radiology"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001603","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:20:09Z","timestamp":1754176809000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001603"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,8]]},"references-count":25,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001603","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"type":"electronic","value":"1532-3145"},{"type":"print","value":"0363-8715"}],"subject":[],"published":{"date-parts":[[2024,4,8]]}}}