{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:40:03Z","timestamp":1754178003302,"version":"3.41.2"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>This study aimed to compare the image quality of chest computed tomography (CT) scans for COVID-19 pneumonia using forward-projected model-based iterative reconstruction solution-LUNG (FIRST-LUNG) with filtered back projection (FBP) and hybrid iterative reconstruction (HIR).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method<\/jats:title>\n            <jats:p>The CT images of 44 inpatients diagnosed with COVID-19 pneumonia between December 2022 and June 2023 were retrospectively analyzed. The CT images were reconstructed using FBP, HIR, and FIRST-LUNG-MILD\/STANDARD\/STRONG. The CT values and noise of the lumen of the main trachea and erector spine muscle were measured for each group. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective evaluations included overall image quality, noise, streak artifact, visualization of normal lung structures, and abnormal CT features. One-way analysis of variance was used to compare the objective and subjective indicators among the five groups. The task-based transfer function was derived for three distinct contrasts representing anatomical structures, lower-contrast lesion, and higher-contrast lesion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The results of the study demonstrated significant differences in image noise, SNR, and CNR among the five groups (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). The FBP images exhibited the highest levels of noise and the lowest SNR and CNR among the five groups (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). When compared to the FBP and HIR groups, the noise was lower in the FIRST-LUNG-MILD\/STANDARD\/STRONG group, while the SNR and CNR were higher (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). The subjective overall image quality score of FIRST-LUNG-MILD\/STANDARD was significantly better than FBP and FIRST-LUNG-STRONG (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). FIRST-LUNG-MILD was superior to FBP, HIR, FIRST-LUNG-STANDARD, and FIRST-LUNG-STRONG in visualizing proximal and peripheral bronchovascular and subpleural vessels (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05). Additionally, FIRST-LUNG-MILD achieved the best scores in evaluating abnormal lung structure (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). The overall interobserver agreement was substantial (intraclass correlation coefficient = 0.891). The task-based transfer function 50% values of FIRST reconstructions are consistently higher compared to FBP and HIR.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The FIRST-LUNG-MILD\/STANDARD algorithm can enhance the image quality of chest CT in patients with COVID-19 pneumonia, while preserving important details of the lesions, better than the FBP and HIR algorithms. After evaluating various COVID-19 pneumonia lesions and considering the improvement in image quality, we recommend using the FIRST-LUNG-MILD reconstruction for diagnosing COVID-19 pneumonia.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001635","type":"journal-article","created":{"date-parts":[[2024,6,26]],"date-time":"2024-06-26T14:06:18Z","timestamp":1719410778000},"page":"936-942","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Effect of Model-Based Iterative Reconstruction on Image Quality of Chest Computed Tomography for COVID-19 Pneumonia"],"prefix":"10.1097","volume":"48","author":[{"given":"Caiyin","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junkun","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingjie","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingfeng","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruzhen","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuejun","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rulin","family":"Xu","sequence":"additional","affiliation":[{"name":"Research Collaboration, Canon Medical Systems, Guangzhou, Guangdong, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiping","family":"Zhong","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,6,25]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"451","DOI":"10.3390\/microorganisms10020451","article-title":"Literature review of Omicron: a grim reality amidst COVID-19","volume":"10","year":"2022","journal-title":"Microorganisms"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.ajem.2022.01.028","article-title":"Clinical update on COVID-19 for the emergency clinician: presentation and evaluation","volume":"54","year":"2022","journal-title":"Am J Emerg Med"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1002\/jmv.26218","article-title":"Meta-analysis of chest CT features of patients with COVID-19 pneumonia","volume":"93","year":"2021","journal-title":"J Med Virol"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"5446","DOI":"10.1007\/s00330-020-06879-6","article-title":"Imaging features and evolution on CT in 100 COVID-19 pneumonia patients in Wuhan, China","volume":"30","year":"2020","journal-title":"Eur Radiol"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1007\/s11547-020-01237-4","article-title":"Chest CT features of coronavirus disease 2019 (COVID-19) pneumonia: key points for radiologists","volume":"125","year":"2020","journal-title":"Radiol Med"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1148\/radiol.2020201365","article-title":"The role of chest imaging in patient management during the COVID-19 pandemic: a multinational consensus statement from the Fleischner Society","volume":"296","year":"2020","journal-title":"Radiology"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"E115","DOI":"10.1148\/radiol.2020200432","article-title":"Sensitivity of chest CT for COVID-19: comparison to RT-PCR","volume":"296","year":"2020","journal-title":"Radiology"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.dib.2016.11.084","article-title":"Subjective and objective evaluation of 10-30% dose reduced coronary artery phantom scans reconstructed with Forward projected model-based Iterative Reconstruction SoluTion (FIRST)","volume":"10","year":"2017","journal-title":"Data Brief"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"20160114","DOI":"10.1259\/dmfr.20160114","article-title":"Metal artefact reduction for patients with metallic dental fillings in helical neck computed tomography: comparison of adaptive iterative dose reduction 3D (AIDR 3D), forward-projected model-based iterative reconstruction solution (FIRST) and AIDR 3D with single-energy metal artefact reduction (SEMAR)","volume":"45","year":"2016","journal-title":"Dentomaxillofac Radiol"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.jcct.2016.11.002","article-title":"The feasibility of Forward-projected model-based Iterative Reconstruction SoluTion (FIRST) for coronary 320-row computed tomography angiography: a pilot study","volume":"11","year":"2017","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.ejro.2019.05.001","article-title":"Can fully iterative reconstruction technique enable routine abdominal CT at less than 1 mSv?","volume":"6","year":"2019","journal-title":"Eur J Radiol Open"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"548","DOI":"10.2214\/AJR.17.19245","article-title":"Forward-projected model-based iterative reconstruction in screening low-dose chest CT: comparison with adaptive iterative dose reduction 3D","volume":"211","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.chest.2018.09.007","article-title":"Chest CT scan at radiation dose of a posteroanterior and lateral chest radiograph series: a proof of principle in lymphangioleiomyomatosis","volume":"155","year":"2019","journal-title":"Chest"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1097\/RCT.0000000000001037","article-title":"Evaluation of image quality for 7 iterative reconstruction algorithms in chest computed tomography imaging: a phantom study","volume":"44","year":"2020","journal-title":"J Comput Assist Tomogr"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/j.jtho.2020.02.010","article-title":"Pulmonary pathology of early-phase 2019 novel coronavirus (COVID-19) pneumonia in two patients with lung cancer","volume":"15","year":"2020","journal-title":"J Thorac Oncol"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1164\/rccm.202003-0736LE","article-title":"Clinical course and outcomes of 344 intensive care patients with COVID-19","volume":"201","year":"2020","journal-title":"Am J Respir Crit Care Med"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1097\/RLI.0000000000000689","article-title":"The performance of chest CT in evaluating the clinical severity of COVID-19 pneumonia: identifying critical cases based on CT characteristics","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.virol.2020.08.011","article-title":"The novel coronavirus disease-2019 (COVID-19): mechanism of action, detection and recent therapeutic strategies","volume":"551","year":"2020","journal-title":"Virology"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"772","DOI":"10.2214\/AJR.13.12312","article-title":"Submillisievert chest CT with filtered back projection and iterative reconstruction techniques","volume":"203","year":"2014","journal-title":"AJR Am J Roentgenol"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1097\/RCT.0b013e3181b26c67","article-title":"Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience","volume":"34","year":"2010","journal-title":"J Comput Assist Tomogr"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1007\/s11604-011-0026-7","article-title":"Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography","volume":"30","year":"2012","journal-title":"Jpn J Radiol"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"649","DOI":"10.2214\/AJR.10.4285","article-title":"Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography","volume":"195","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1148\/radiol.2015132766","article-title":"State of the art: iterative CT reconstruction techniques","volume":"276","year":"2015","journal-title":"Radiology"},{"key":"bib24-20250802","first-page":"4515","article-title":"Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study","volume":"15","year":"2014","journal-title":"J Appl Clin Med Phys"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"2185","DOI":"10.1007\/s00330-018-5810-7","article-title":"The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence","volume":"29","year":"2019","journal-title":"Eur Radiol"},{"key":"bib26-20250802","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1118\/1.4903899","article-title":"Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology","volume":"42","year":"2015","journal-title":"Med Phys"},{"key":"bib27-20250802","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.ejmp.2011.12.004","article-title":"Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments\u2013a phantom approach","volume":"29","year":"2013","journal-title":"Phys Med"},{"key":"bib28-20250802","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/1471-2342-13-27","article-title":"CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction","volume":"13","year":"2013","journal-title":"BMC Med Imaging"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1097\/RLI.0b013e31827efc3a","article-title":"Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique","volume":"48","year":"2013","journal-title":"Invest Radiol"},{"key":"bib30-20250802","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1016\/j.crad.2013.03.024","article-title":"Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT","volume":"68","year":"2013","journal-title":"Clin Radiol"},{"key":"bib31-20250802","doi-asserted-by":"crossref","first-page":"4529","DOI":"10.1007\/s00330-018-5969-y","article-title":"Feasibility of low-dose CT with spectral shaping and third-generation iterative reconstruction in evaluating interstitial lung diseases associated with connective tissue disease: an intra-individual comparison study","volume":"29","year":"2019","journal-title":"Eur Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001635","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:13:05Z","timestamp":1754176385000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001635"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,25]]},"references-count":31,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001635","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"type":"electronic","value":"1532-3145"},{"type":"print","value":"0363-8715"}],"subject":[],"published":{"date-parts":[[2024,6,25]]}}}