{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T19:11:14Z","timestamp":1790795474044,"version":"4.1.0"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Comput Assist Tomogr"],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aims to evaluate, on one MRI vendor's platform, the impact of deep learning (DL)\u2013based reconstruction techniques on MRI radiomic features compared to conventional image reconstruction techniques.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Under IRB approval and informed consent, we prospectively collected undersampled coronal T2-weighted MR images of the abdomen (1.5 T; Philips Healthcare) from 17 pediatric and adult subjects and reconstructed them using a conventional image reconstruction technique (compressed sensitivity encoding [C-SENSE]) and two DL-based reconstruction techniques (SmartSpeed [Philips Healthcare, US FDA cleared] and SmartSpeed with Super Resolution [SmartSpeed-SuperRes, not US FDA cleared to date]). Eight regions of interest (ROIs) across organs\/tissues (liver, spleen, kidney, pancreas, fat, and muscle) were manually placed. Eighty-six MRI radiomic features were then extracted. Pearson's correlation coefficients (PCCs) and intraclass correlation coefficients (ICCs) were calculated between (A) C-SENSE versus SmartSpeed, and (B) C-SENSE versus SmartSpeed-SuperRes. To quantify the impact from the perspective of the whole MR image, cross-ROI mean PCCs and ICCs were calculated for individual radiomic features. The impact of image reconstruction on individual radiomic features in different organs\/tissues was evaluated using ANOVA analyses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      According to cross-ROI mean PCCs, 50 out of 86 radiomic features were highly correlated (PCC, \u22650.8) between SmartSpeed and C-SENSE, whereas only 15 radiomic features were highly correlated between SmartSpeed-SuperRes and C-SENSE reconstructions. According to cross-ROI mean ICCs, 58 out of 86 radiomic features had high agreements (ICC \u22650.75) between SmartSpeed and C-SENSE, whereas only 9 radiomic features had high agreements between SmartSpeed-SuperRes and C-SENSE reconstructions. For SmartSpeed reconstruction, the psoas muscle ROI appeared to be impacted most with the lowest median (IQR) correlation of 0.57 (0.25). The circular liver ROI was impacted most by SmartSpeed-SuperRes (PCC, 0.60 [0.22]). ANOVA analyses suggest that the impact of DL reconstruction algorithms on radiomic features varies significantly among different organs\/tissues (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>MRI radiomic features are significantly altered by DL-based reconstruction compared to a conventional reconstruction technique. The impact of DL reconstruction algorithms on radiomic features varies significantly between different organs\/tissues.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001648","type":"journal-article","created":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T14:00:51Z","timestamp":1724767251000},"page":"955-962","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Impact of Emerging Deep Learning\u2013Based MR Image Reconstruction Algorithms on Abdominal MRI Radiomic Features"],"prefix":"10.1097","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5267-2875","authenticated-orcid":false,"given":"Hailong","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vinicius Vieira","family":"Alves","sequence":"additional","affiliation":[{"name":"Department of Radiology, Cincinnati Children's Hospital Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amol","family":"Pednekar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary Kate","family":"Manhard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua","family":"Greer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew T.","family":"Trout","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lili","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan R.","family":"Dillman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,8,22]]},"reference":[{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1002\/jmri.23639","article-title":"Parallel MR imaging","volume":"36","year":"2012","journal-title":"J Magn Reson Imaging"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"20150487","DOI":"10.1259\/bjr.20150487","article-title":"Compressed sensing MRI: a review of the clinical literature","volume":"88","year":"2015","journal-title":"Br J Radiol"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1002\/mrm.22161","article-title":"Accelerating SENSE using compressed sensing","volume":"62","year":"2009","journal-title":"Magn Reson Med"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","article-title":"SENSE: sensitivity encoding for fast MRI","volume":"42","year":"1999","journal-title":"Magn Reson Med"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized autocalibrating partially parallel acquisitions (GRAPPA)","volume":"47","year":"2002","journal-title":"Magn Reson Med"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","article-title":"Sparse MRI: the application of compressed sensing for rapid MR imaging","volume":"58","year":"2007","journal-title":"Magn Reson Med"},{"key":"bib9-20250802","first-page":"111","article-title":"Compressed sensing: from research to clinical practice with deep neural networks","volume":"37","year":"2020","journal-title":"IEEE Signal Process Mag"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"13710","DOI":"10.1038\/s41598-020-70551-8","article-title":"CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions","volume":"10","year":"2020","journal-title":"Sci Rep"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1002\/mrm.28420","article-title":"Accelerating cardiac cine MRI using a deep learning-based ESPIRiT reconstruction","volume":"85","year":"2021","journal-title":"Magn Reson Med"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1148\/radiol.2021202624","article-title":"Free-breathing accelerated cardiac MRI using deep learning: validation in children and young adults","volume":"300","year":"2021","journal-title":"Radiology"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"204825","DOI":"10.1109\/ACCESS.2020.3034287","article-title":"An adaptive intelligence algorithm for undersampled knee MRI reconstruction","volume":"8","year":"2020","journal-title":"IEEE Access"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1148\/radiol.2020192173","article-title":"Deep learning single-frame and multiframe super-resolution for cardiac MRI","volume":"295","year":"2020","journal-title":"Radiology"},{"key":"bib17-20250802","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1148\/radiol.2015151169","article-title":"Radiomics: images are more than pictures, they are data","volume":"278","year":"2016","journal-title":"Radiology"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"e104","DOI":"10.1158\/0008-5472.CAN-17-0339","article-title":"Computational radiomics system to decode the radiographic phenotype","volume":"77","year":"2017","journal-title":"Cancer Res"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.ejca.2011.11.036","article-title":"Radiomics: extracting more information from medical images using advanced feature analysis","volume":"48","year":"2012","journal-title":"Eur J Cancer"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1148\/radiol.2020191145","article-title":"The image biomarker standardization initiative: standardized quantitative radiomics for high-throughput image-based phenotyping","volume":"295","year":"2020","journal-title":"Radiology"},{"key":"bib21-20250802","article-title":"Radiomics in paediatric neuro-oncology: a multicentre study on MRI texture analysis","volume":"31","year":"2018","journal-title":"NMR Biomed"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"4006","DOI":"10.1038\/ncomms5006","article-title":"Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach","volume":"5","year":"2014","journal-title":"Nat Commun"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"387","DOI":"10.3348\/kjr.2019.0752","article-title":"Radiomics and deep learning: hepatic applications","volume":"21","year":"2020","journal-title":"Korean J Radiol"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"592","DOI":"10.2214\/AJR.19.21082","article-title":"Machine learning prediction of liver stiffness using clinical and T2-weighted MRI radiomic data","volume":"213","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"bib25-20250802","first-page":"743","article-title":"Making qualitative intestinal stricture quantitative: embracing radiomics in IBD","volume":"26","year":"2019","journal-title":"Inflamm Bowel Dis"},{"key":"bib26-20250802","doi-asserted-by":"crossref","first-page":"277","DOI":"10.3390\/jimaging8100277","article-title":"Quantitative analysis of liver disease using MRI-based radiomic features of the liver and spleen","volume":"8","year":"2022","journal-title":"J Imaging"},{"key":"bib27-20250802","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1080\/23808993.2019.1585805","article-title":"Deep learning and radiomics in precision medicine","volume":"4","year":"2019","journal-title":"Expert Rev Precis Med Drug Dev"},{"key":"bib28-20250802","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1037\/1082-989X.1.1.30","article-title":"Forming inferences about some intraclass correlation coefficients","volume":"1","year":"1996","journal-title":"Psychol Methods"},{"issue":"4 Suppl 1","key":"bib29-20250802","first-page":"S35","article-title":"Correlation and regression analysis","volume":"103","year":"2009","journal-title":"Ann Allergy Asthma Immunol"},{"key":"bib30-20250802","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","article-title":"Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology","volume":"6","year":"1994","journal-title":"Psychol Assess"},{"key":"bib31-20250802","article-title":"Harmonic unpaired image-to-image translation","year":"2019","journal-title":"arXiv preprint arXiv"},{"key":"bib32-20250802","doi-asserted-by":"crossref","first-page":"15171","DOI":"10.1038\/s41598-022-19546-1","article-title":"Deep learning-based reconstruction on cardiac CT yields distinct radiomic features compared to iterative and filtered back projection reconstructions","volume":"12","year":"2022","journal-title":"Sci Rep"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001648","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T23:12:20Z","timestamp":1754176340000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001648"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,22]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001648","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2024,8,22]]}}}