{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,3]],"date-time":"2025-06-03T04:03:03Z","timestamp":1748923383905,"version":"3.41.0"},"reference-count":38,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>This study aimed to evaluate the image quality and visualization of hepatocellular carcinoma (HCC) on arterial phase computed tomography (CT) using the contrast enhancement (CE)\u2013boost technique.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This retrospective study included 527 consecutive patients who underwent dynamic liver CT between June 2021 and February 2022. Quantitative and qualitative image analyses were performed on 486 patients after excluding 41 patients. HCC conspicuity was evaluated in 40 of the 486 patients with at least one HCC in the liver. Iodinated images obtained by subtracting nonenhanced images from arterial phase images were combined to generate CE-boost images. For quantitative image analysis, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured for the liver, pancreas, muscles, and aorta. For qualitative analysis, the overall image quality and noise were graded using a 3-point scale. Artifact, sharpness, and HCC lesion conspicuity were assessed using a 5-point scale. The paired-sample <jats:italic toggle=\"yes\">t<\/jats:italic> test was used to compare quantitative measures, whereas the Wilcoxon signed-rank test was used to compare qualitative measures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The mean SNR and CNR of the aorta, liver, pancreas, and muscle were significantly higher, and the image noise was significantly lower in the CE-boost images than in the conventional images (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2009&lt;\u20090.001). The mean CNR of HCC was also significantly higher in the CE-boost images than in the conventional images (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2009&lt;\u20090.001). In the qualitative analysis, CE-boost images showed higher scores for HCC lesion conspicuity than conventional images (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2009&lt;\u20090.001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The overall image quality and visibility of HCC were improved using the CE-boost technique.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rct.0000000000001684","type":"journal-article","created":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T06:01:33Z","timestamp":1731045693000},"page":"348-357","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Improving Image Quality and Visualization of Hepatocellular Carcinoma in Arterial Phase Imaging Using Contrast Enhancement\u2013Boost Technique"],"prefix":"10.1097","volume":"49","author":[{"given":"Gayoung","family":"Yoon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jhii-Hyun","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sang-Hyun","family":"Jeon, BS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,11,5]]},"reference":[{"key":"bib1-20250602","doi-asserted-by":"crossref","first-page":"229","DOI":"10.3322\/caac.21834","article-title":"Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"74","author":"Bray","year":"2024","journal-title":"CA Cancer J Clin"},{"key":"bib2-20250602","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.jhep.2019.08.025","article-title":"Epidemiology and surveillance for hepatocellular carcinoma: new trends","volume":"72","author":"Singal","year":"2020","journal-title":"J Hepatol"},{"key":"bib3-20250602","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1038\/s41571-023-00825-3","article-title":"Global trends in hepatocellular carcinoma epidemiology: implications for screening, prevention and therapy","volume":"20","author":"Singal","year":"2023","journal-title":"Nat Rev Clin Oncol"},{"key":"bib4-20250602","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.3348\/kjr.2022.0822","article-title":"2022 KLCA-NCC Korea practice guidelines for the management of hepatocellular carcinoma","volume":"23","year":"2022","journal-title":"Korean J Radiol"},{"key":"bib5-20250602","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1148\/radiol.2018181494","article-title":"Liver imaging reporting and data system (LI-RADS) version 2018: imaging of hepatocellular carcinoma in at-risk patients","volume":"289","author":"Chernyak","year":"2018","journal-title":"Radiology"},{"key":"bib6-20250602","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1016\/j.acra.2019.01.009","article-title":"Contrast enhancement boost technique at aortic computed tomography angiography: added value for the evaluation of type II endoleaks after endovascular aortic aneurysm repair","volume":"26","author":"Iizuka","year":"2019","journal-title":"Acad Radiol"},{"key":"bib7-20250602","doi-asserted-by":"crossref","first-page":"110388","DOI":"10.1016\/j.ejrad.2022.110388","article-title":"Effects of contrast enhancement boost postprocessing technique in combination with different reconstruction algorithms on the image quality of abdominal CT angiography","volume":"154","author":"Xu","year":"2022","journal-title":"Eur J Radiol"},{"key":"bib8-20250602","doi-asserted-by":"crossref","first-page":"e0284793","DOI":"10.1371\/journal.pone.0284793","article-title":"The effectiveness of post-processing head and neck CT angiography using contrast enhancement boost technique","volume":"18","author":"Otgonbaatar","year":"2023","journal-title":"PLoS One"},{"key":"bib9-20250602","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1007\/s00261-022-03754-4","article-title":"Clinical application of the contrast-enhancement boost technique in computed tomography angiography of the portal vein","volume":"48","author":"Hou","year":"2023","journal-title":"Abdom Radiol (NY)"},{"key":"bib10-20250602","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1148\/radiol.09090094","article-title":"Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience","volume":"254","author":"Marin","year":"2010","journal-title":"Radiology"},{"key":"bib11-20250602","doi-asserted-by":"crossref","first-page":"3156","DOI":"10.1007\/s00330-020-07358-8","article-title":"CT iterative vs deep learning reconstruction: comparison of noise and sharpness","volume":"31","author":"Park","year":"2021","journal-title":"Eur Radiol"},{"key":"bib12-20250602","doi-asserted-by":"crossref","first-page":"402","DOI":"10.3348\/kjr.2021.0683","article-title":"Image quality and lesion detectability of lower-dose abdominopelvic CT obtained using deep learning image reconstruction","volume":"23","author":"Park","year":"2022","journal-title":"Korean J Radiol"},{"key":"bib13-20250602","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1148\/radiol.2323031563","article-title":"Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters","volume":"232","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"bib14-20250602","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1148\/radiol.2373041655","article-title":"Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise","volume":"237","author":"Nakayama","year":"2005","journal-title":"Radiology"},{"key":"bib15-20250602","doi-asserted-by":"crossref","first-page":"20201357","DOI":"10.1259\/bjr.20201357","article-title":"Superior objective and subjective image quality of deep learning reconstruction for low-dose abdominal CT imaging in comparison with model-based iterative reconstruction and filtered back projection","volume":"94","author":"Tamura","year":"2021","journal-title":"Br J Radiol"},{"key":"bib16-20250602","first-page":"1565","article-title":"Interobserver agreement for grating acuity and letter acuity assessment in 1- to 5.5-year-olds with severe retinopathy of prematurity","volume":"40","author":"Harvey","year":"1999","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib17-20250602","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1148\/radiology.195.2.7724752","article-title":"Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement","volume":"195","author":"Heiken","year":"1995","journal-title":"Radiology"},{"key":"bib18-20250602","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1148\/radiology.201.2.8888218","article-title":"Dual-phase helical CT of the liver: effects of bolus tracking and different volumes of contrast material","volume":"201","author":"Kopka","year":"1996","journal-title":"Radiology"},{"key":"bib19-20250602","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1148\/radiology.216.3.r00se26718","article-title":"Abdominal helical CT: evaluation of optimal doses of intravenous contrast material\u2014a prospective randomized study","volume":"216","author":"Yamashita","year":"2000","journal-title":"Radiology"},{"key":"bib20-20250602","doi-asserted-by":"crossref","first-page":"1535","DOI":"10.2214\/ajr.184.5.01841535","article-title":"MDCT of hypervascular hepatocellular carcinomas: a prospective study using contrast materials with different iodine concentrations","volume":"184","author":"Yagyu","year":"2005","journal-title":"AJR Am J Roentgenol"},{"key":"bib21-20250602","doi-asserted-by":"crossref","first-page":"e237","DOI":"10.1016\/j.ejrad.2010.10.006","article-title":"Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver: comparison of different concentrations of contrast material with multi-detector row helical CT\u2014a prospective randomized study","volume":"80","author":"Sofue","year":"2011","journal-title":"Eur J Radiol"},{"key":"bib22-20250602","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1148\/radiology.206.2.9457200","article-title":"Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate\u2014pharmacokinetic analysis and experimental porcine model","volume":"206","author":"Bae","year":"1998","journal-title":"Radiology"},{"key":"bib23-20250602","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.ejrad.2019.03.008","article-title":"Nephrotoxicity of iodinated contrast media: from pathophysiology to prevention strategies","volume":"116","author":"Faucon","year":"2019","journal-title":"Eur J Radiol"},{"key":"bib24-20250602","doi-asserted-by":"crossref","first-page":"e0055","DOI":"10.1097\/MD.0000000000010055","article-title":"MRI and CT contrast media extravasation: a systematic review","volume":"97","author":"Heshmatzadeh Behzadi","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"bib25-20250602","doi-asserted-by":"crossref","first-page":"20210601","DOI":"10.1259\/bjr.20210601","article-title":"Diagnostic performance and image quality of low-tube voltage and low-contrast medium dose protocol with hybrid iterative reconstruction for hepatic dynamic CT","volume":"94","author":"Ichikawa","year":"2021","journal-title":"Br J Radiol"},{"key":"bib26-20250602","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1016\/j.ejrad.2013.12.014","article-title":"Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?","volume":"83","author":"Takahashi","year":"2014","journal-title":"Eur J Radiol"},{"key":"bib27-20250602","doi-asserted-by":"crossref","first-page":"1404","DOI":"10.1007\/s00261-017-1327-9","article-title":"Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study","volume":"43","author":"Hanson","year":"2018","journal-title":"Abdom Radiol (NY)"},{"key":"bib28-20250602","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1148\/radiol.2019182297","article-title":"Review of clinical applications for virtual Monoenergetic dual-energy CT","volume":"293","author":"Albrecht","year":"2019","journal-title":"Radiology"},{"key":"bib29-20250602","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.1007\/s00330-017-5114-3","article-title":"Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol","volume":"28","author":"Nagayama","year":"2018","journal-title":"Eur Radiol"},{"key":"bib30-20250602","doi-asserted-by":"crossref","first-page":"6163","DOI":"10.1007\/s00330-019-06170-3","article-title":"Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT","volume":"29","author":"Akagi","year":"2019","journal-title":"Eur Radiol"},{"key":"bib31-20250602","doi-asserted-by":"crossref","first-page":"50","DOI":"10.2214\/AJR.19.22332","article-title":"Image quality assessment of abdominal CT by use of new deep learning image reconstruction: initial experience","volume":"215","author":"Jensen","year":"2020","journal-title":"AJR Am J Roentgenol"},{"key":"bib32-20250602","doi-asserted-by":"crossref","first-page":"3430","DOI":"10.1007\/s00261-023-04039-0","article-title":"Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis","volume":"48","author":"Lee","year":"2023","journal-title":"Abdom Radiol (NY)"},{"key":"bib33-20250602","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1007\/s00270-015-1208-y","article-title":"Treatment of liver tumors with Lipiodol TACE: technical recommendations from experts opinion","volume":"39","author":"de Baere","year":"2016","journal-title":"Cardiovasc Intervent Radiol"},{"key":"bib34-20250602","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1186\/s40644-019-0260-2","article-title":"Lipiodol retention pattern after TACE for HCC is a predictor for local progression in lesions with complete response","volume":"19","author":"Dioguardi Burgio","year":"2019","journal-title":"Cancer Imaging"},{"key":"bib35-20250602","doi-asserted-by":"crossref","first-page":"51","DOI":"10.3348\/kjr.2013.14.1.51","article-title":"Detection of recurrent hepatocellular carcinoma in cirrhotic liver after transcatheter arterial chemoembolization: value of quantitative color mapping of the arterial enhancement fraction of the liver","volume":"14","author":"Lee","year":"2013","journal-title":"Korean J Radiol"},{"key":"bib36-20250602","doi-asserted-by":"crossref","first-page":"3242","DOI":"10.3748\/wjg.v22.i11.3242","article-title":"Application of gemstone spectral imaging for efficacy evaluation in hepatocellular carcinoma after transarterial chemoembolization","volume":"22","author":"Liu","year":"2016","journal-title":"World J Gastroenterol"},{"key":"bib37-20250602","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.ejrad.2012.11.014","article-title":"Dual-energy CT to detect recurrent HCC after TACE: initial experience of color-coded iodine CT imaging","volume":"82","author":"Lee","year":"2013","journal-title":"Eur J Radiol"},{"key":"bib38-20250602","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1097\/RLI.0000000000000714","article-title":"Added value of CT arterial subtraction images in liver imaging reporting and data system treatment response categorization for transcatheter arterial chemoembolization-treated hepatocellular carcinoma","volume":"56","author":"Huh","year":"2021","journal-title":"Invest Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001684","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T11:00:50Z","timestamp":1748862050000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001684"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,5]]},"references-count":38,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001684","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"type":"electronic","value":"1532-3145"},{"type":"print","value":"0363-8715"}],"subject":[],"published":{"date-parts":[[2024,11,5]]}}}