{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T13:24:29Z","timestamp":1781270669725,"version":"3.54.1"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>Adoption of abdominal photon counting detector CT (PCD-CT) into clinical pediatric CT practice requires evidence that it provides diagnostic images at acceptable radiation doses. Thus, this study aimed to compare radiation dose and image quality of PCD-CT and conventional energy-integrating detector CT (EID-CT) in pediatric abdominopelvic CT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      This institutional review board\u2013approved retrospective study included 147 children (median age 8.5\u00a0y; 80 boys, 67 girls) who underwent clinically indicated contrast-enhanced abdominopelvic PCD-CT between October 1, 2022 and April 30, 2023 and 147 children (median age 8.5\u00a0y; 74 boys, 73 girls) who underwent EID-CT between July 1, 2021 and January 1, 2022. Patients in the 2 groups were matched by age and effective diameter. Radiation dose parameters (CT dose index volume, CTDI\n                      <jats:sub>vol<\/jats:sub>\n                      ; dose length product, DLP; size-specific dose estimate, SSDE) were recorded. In a subset of 25 matched pairs, subjective image quality was assessed on a scale of 1 to 4 (1=highest quality), and liver attenuation, dose-normalized noise, and contrast-to-noise ratio (CNR) were measured. Groups were compared using parametric and\/or nonparametric testing.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Among the 147 matched pairs, there were no significant differences in sex (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.576), age (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.084), or diameter (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.668). PCD-CT showed significantly lower median CTDI\n                      <jats:sub>vol<\/jats:sub>\n                      , DLP, and SSDE (1.6\u00a0mGy, 63.8\u00a0mGy-cm, 3.1\u00a0mGy) compared with EID-CT (3.7\u00a0mGy, 155.3\u00a0mGy-cm, 6.0\u00a0mGy) (\n                      <jats:italic toggle=\"yes\">P&lt;<\/jats:italic>\n                      0.001). In the subset of 25 patients, PCD-CT and EID-CT showed no significant difference in overall image quality for reader 1 (1.0 vs. 1.0,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.781) or reader 2 (1.0 vs. 1.0,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.817), or artifacts for reader 1 (1.0 vs. 1.0,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.688) or reader 2 (1.0 vs. 1.0,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.219). After normalizing for radiation dose, image noise was significantly lower with PCD-CT (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001), while CNR in the liver (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.244) and portal vein (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.079) were comparable to EID-CT.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Abdominopelvic PCD-CT in children significantly reduces radiation dose while maintaining subjective image quality, and accounting for dose levels, has the potential to lower image noise and achieve comparable CNR to EID-CT. These data expand understanding of the capabilities of PCD-CT and support its routine use in children.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001730","type":"journal-article","created":{"date-parts":[[2025,2,5]],"date-time":"2025-02-05T04:00:16Z","timestamp":1738728016000},"page":"73-80","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Comparison of Radiation Dose and Image Quality in Pediatric Abdominopelvic Photon-Counting Versus Energy-Integrating Detector CT"],"prefix":"10.1097","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8342-8293","authenticated-orcid":false,"given":"Marilyn J.","family":"Siegel","sequence":"first","affiliation":[{"name":"Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew Allan","family":"Thomas","sequence":"additional","affiliation":[{"name":"Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adeel","family":"Haq","sequence":"additional","affiliation":[{"name":"Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noah","family":"Seymore","sequence":"additional","affiliation":[{"name":"Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kushaljit Singh","family":"Sodhi","sequence":"additional","affiliation":[{"name":"Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andres","family":"Abadia","sequence":"additional","affiliation":[{"name":"Siemens Healthcare, Malvern, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,1]]},"reference":[{"key":"R1-20260119","doi-asserted-by":"crossref","first-page":"854","DOI":"10.3348\/kjr.2022.0377","article-title":"Photon-counting detector CT: key points radiologists should know","volume":"23","author":"Esquivel","year":"2022","journal-title":"Korean J Radiol"},{"key":"R2-20260119","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1097\/RLI.0000000000000980","article-title":"Technical basics and clinical benefits of photon-counting CT","volume":"58","author":"Flohr","year":"2023","journal-title":"Invest Radiol"},{"key":"R3-20260119","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1148\/rg.2019180115","article-title":"Photon-counting detector CT: system design and clinical applications of an emerging technology","volume":"39","author":"Leng","year":"2019","journal-title":"Radiographics"},{"key":"R4-20260119","doi-asserted-by":"crossref","first-page":"5321","DOI":"10.1007\/s00330-023-09545-9","article-title":"The technical development of photon-counting detector CT","volume":"33","author":"McCollough","year":"2023","journal-title":"Eur Radiol"},{"key":"R5-20260119","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1148\/radiol.212579","article-title":"First clinical photon-counting detector CT system: Technical evaluation","volume":"303","author":"Rajendran","year":"2022","journal-title":"Radiology"},{"key":"R6-20260119","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon-counting CT: technical principles and clinical prospects","volume":"289","author":"Willemink","year":"2018","journal-title":"Radiology"},{"key":"R7-20260119","doi-asserted-by":"crossref","first-page":"e1910584","DOI":"10.1001\/jamanetworkopen.2019.10584","article-title":"Association of exposure to diagnostic low-dose ionizing radiation with risk of cancer among youths in South Korea.","volume":"2","author":"Hong","year":"2019","journal-title":"JAMA Netw Open"},{"key":"R8-20260119","doi-asserted-by":"crossref","first-page":"f2360","DOI":"10.1136\/bmj.f2360","article-title":"Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians","volume":"346","author":"Mathews","year":"2013","journal-title":"BMJ"},{"key":"R9-20260119","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1007\/s00247-020-04909-5","article-title":"Clinical concordance with image gently guidelines for pediatric computed tomography: a study across 663,417 CT scans at 53 clinical facilities","volume":"51","author":"Smith","year":"2021","journal-title":"Pediatr Radiol"},{"key":"R10-20260119","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1007\/s00247-022-05574-6","article-title":"Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs","volume":"53","author":"Horst","year":"2023","journal-title":"Pediatr Radiol"},{"key":"R11-20260119","doi-asserted-by":"crossref","first-page":"363","DOI":"10.2214\/AJR.23.29077","article-title":"Comparison of photon-counting detector CT with energy-integrated detector CT on radiation dose and image quality in pediatric high-resolution chest CT","volume":"221","author":"Siegel","year":"2023","journal-title":"AJR Am J Roentgenol"},{"key":"R12-20260119","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1007\/s00247-022-05584-4","article-title":"Low dose pediatric chest computed tomography on a photon counting detector system-initial clinical experience","volume":"53","author":"Tsifikas","year":"2023","journal-title":"Pediatr Radiol"},{"key":"R13-20260119","doi-asserted-by":"crossref","first-page":"e223088","DOI":"10.1148\/radiol.223088","article-title":"Photon-counting versus dual-source CT of congenital heart defects in neonates and infants; initial experience","volume":"307","author":"Dirrichs","year":"2023","journal-title":"Radiology"},{"key":"R14-20260119","doi-asserted-by":"crossref","first-page":"580","DOI":"10.2214\/AJR.22.28391","article-title":"Pediatric applications of photon-counting detector CT","volume":"220","author":"Cao","year":"2023","journal-title":"AJR Am J Roentgenol"},{"key":"R15-20260119","doi-asserted-by":"crossref","first-page":"20230189","DOI":"10.1259\/bjr.20230189","article-title":"Potential benefits of photon counting detector computed tomography in pediatric imaging","volume":"96","author":"Horst","year":"2023","journal-title":"Br J Radiol"},{"key":"R16-20260119","first-page":"1","article-title":"US diagnostic reference levels and achievable doses for 10 pediatric CT examinations","volume":"000","author":"Kanal","year":"2021","journal-title":"Radiology"},{"key":"R17-20260119","doi-asserted-by":"crossref","first-page":"e230024","DOI":"10.1148\/ryai.230024","article-title":"TotalSegmentator: robust segmentation of 104 anatomic structures in CT images","volume":"5","author":"Wasserthal","year":"2023","journal-title":"Radiol Artif Intell"},{"key":"R18-20260119","doi-asserted-by":"crossref","first-page":"W93","DOI":"10.2214\/AJR.14.13613","article-title":"Automated technique to measure noise in clinical CT examinations","volume":"205","author":"Christianson","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"R19-20260119","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1002\/mp.14635","article-title":"A benchmark for automatic noise measurement in clinical computed tomography","volume":"48","author":"Ahmad","year":"2021","journal-title":"Med Phys"},{"key":"R20-20260119","doi-asserted-by":"crossref","first-page":"2000","DOI":"10.1007\/s00247-021-05127-3","article-title":"Comparison of radiation dose and image quality between contrast-enhanced single- and dual-energy abdominopelvic computed tomography in children as a function of patient size","volume":"51","author":"Siegel","year":"2021","journal-title":"Pediatr Radiol"},{"key":"R21-20260119","doi-asserted-by":"crossref","first-page":"5705","DOI":"10.1002\/mp.12554","article-title":"A method for characterizing and matching CT image quality across CT scanners from different manufacturers","volume":"44","author":"Winslow","year":"2017","journal-title":"Med Phys"},{"key":"R22-20260119","doi-asserted-by":"crossref","first-page":"e14069","DOI":"10.1002\/acm2.14069","article-title":"A methodology for incorporating a photon-counting CT system into routine clinical use","volume":"24","author":"Bache","year":"2023","journal-title":"J Appl Clin Med Phys"},{"key":"R23-20260119","doi-asserted-by":"crossref","first-page":"2461","DOI":"10.1007\/s00330-022-09278-1","article-title":"Initial experience on abdominal photon-counting tomography in clinical routine: general image quality and dose exposure","volume":"33","author":"Becker","year":"2023","journal-title":"Eur Radiol"},{"key":"R24-20260119","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"R25-20260119","doi-asserted-by":"crossref","first-page":"4383","DOI":"10.1007\/s00261-024-04414-5","article-title":"Photon-counting CT: technical features and clinical impact on abdominal imaging","volume":"49","author":"Onishi","year":"2024","journal-title":"Abdom Radiol"},{"key":"R26-20260119","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/j.acra.2021.06.018","article-title":"Contrast-enhanced abdominal CT with clinical photon-counting detector CT: assessment of image quality and comparison with energy-integrating detector CT","volume":"29","author":"Higashigaito","year":"2022","journal-title":"Acad Radiol"},{"key":"R27-20260119","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.jacr.2014.12.017","article-title":"The correct selection of pitch for optimal CT scanning: avoiding common misconceptions","volume":"12","author":"Ranallo","year":"2015","journal-title":"J Am Coll Radiol"},{"key":"R28-20260119","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1002\/acm2.13466","article-title":"The ultrafast, high-pitch turbo FLASH mode of third-generation dual-source CT: effect of different pitch and corresponding SFOV on image quality in a phantom study","volume":"22","author":"Zhou","year":"2021","journal-title":"J Appl Clin Med Phys"},{"key":"R29-20260119","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1007\/s00330-005-0118-9","article-title":"Impact of the z-flying focal spot on resolution and artifact behavior for a 64-slice spiral CT scanner","volume":"16","author":"Kyriakou","year":"2006","journal-title":"Eur Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001730","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T14:00:32Z","timestamp":1768831232000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001730"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,31]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001730","relation":{},"ISSN":["1532-3145"],"issn-type":[{"value":"1532-3145","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,31]]},"assertion":[{"value":"2024-08-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}