{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T02:42:56Z","timestamp":1794278576526,"version":"4.9.0"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To assess photon counting CT iodine density as a marker of histopathologic treatment response after neoadjuvant chemotherapy in patients with pancreatic ductal adenocarcinoma.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      A retrospective PACS search identified 21 pancreatic ductal adenocarcinoma patients [14 men; mean (SD) age: 64 (10)\u00a0y] who underwent neoadjuvant chemotherapy and pancreatic photon counting CT 2 months before resection from April 11, 2022 to February 2, 2024. The histopathologic treatment response grade was the reference standard. Freehand regions-of-interest measurements were drawn independently by 2 radiologists as large as possible within the mass on pancreatic parenchymal phase images. Attenuation, iodine density, and iodine density normalized to the aorta were recorded. Mann-Whitney\n                      <jats:italic toggle=\"yes\">U<\/jats:italic>\n                      test was used to compare attenuation, iodine density, and normalized iodine density for responders (pathologic grade 1, 2) versus nonresponders (grade 3). Receiver operating characteristic curves were created, and optimal thresholds were determined with Youden\u2019s index. A\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.05 indicated statistical significance.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Thirteen of 21 (61.9%) patients showed pathologic treatment response. Iodine density for nonresponders and responders was mean (SD) 0.47 (0.23)\u00a0mg\/mL and 1.20 (0.75)\u00a0mg\/mL, respectively (\n                      <jats:italic toggle=\"yes\">P=<\/jats:italic>\n                      0.005). Normalized iodine density for nonresponders and responders was 7.6 (5.5)% and 22.5 (16.0)%, (\n                      <jats:italic toggle=\"yes\">P=<\/jats:italic>\n                      0.006). Attenuation for nonresponders and responders was 56.5 (10.9)\u00a0HU and 70.6 (17.7)\u00a0HU, (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.04). Upon receiver operating characteristic analysis, an iodine density threshold of 0.65\u00a0mg\/mL had 77% sensitivity and 88% specificity (AUC=0.86), and a normalized iodine density threshold of 10.1% had 77% sensitivity and 88% specificity (AUC=0.86) for treatment response. A 61.8 HU threshold had 77% sensitivity and 75% specificity (AUC=0.78).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Elevated iodine density correlates with pancreatic ductal adenocarcinoma histopathologic treatment response with high specificity. Photon counting CT iodine density may be used as a marker of histopathologic treatment response.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001771","type":"journal-article","created":{"date-parts":[[2025,6,26]],"date-time":"2025-06-26T08:00:18Z","timestamp":1750924818000},"page":"13-19","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["A Pilot Study to Assess Pancreatic Adenocarcinoma Treatment Response With Iodine Density From Photon Counting CT"],"prefix":"10.1097","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-7277-0594","authenticated-orcid":false,"given":"Arthur","family":"Shou","sequence":"first","affiliation":[{"name":"NYU Langone Health Department of Radiology, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barun","family":"Bagga","sequence":"additional","affiliation":[{"name":"NYU Long Island Department of Radiology, Mineola"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina","family":"Hajdu","sequence":"additional","affiliation":[{"name":"NYU Langone Health Department of Pathology, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bari","family":"Dane","sequence":"additional","affiliation":[{"name":"NYU Langone Health Department of Radiology, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,1]]},"reference":[{"key":"R1-20260119","first-page":"12","article-title":"Cancer statistics, 2024","volume":"74","author":"Siegel","year":"2024","journal-title":"CA Cancer J Clin"},{"key":"R2-20260119","doi-asserted-by":"crossref","first-page":"5749","DOI":"10.1002\/cncr.27636","article-title":"Response of borderline resectable pancreatic cancer to neoadjuvant therapy is not reflected by radiographic indicators","volume":"118","author":"Katz","year":"2012","journal-title":"Cancer"},{"key":"R3-20260119","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1148\/radiol.2015151560","article-title":"Correlation between dual-energy and perfusion CT in patients with hepatocellular carcinoma","volume":"280","author":"Gordic","year":"2016","journal-title":"Radiology"},{"key":"R4-20260119","doi-asserted-by":"crossref","first-page":"2532","DOI":"10.1007\/s00330-016-4597-7","article-title":"Dual energy CT allows for improved characterization of response to antiangiogenic treatment in patients with metastatic renal cell cancer","volume":"27","author":"Hellbach","year":"2017","journal-title":"Eur Radiol"},{"key":"R5-20260119","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1097\/RCT.0000000000001009","article-title":"Novel dual-energy computed tomography enterography iodine density maps provide unique depiction of Crohn disease activity","volume":"44","author":"Dane","year":"2020","journal-title":"J Comput Assist Tomogr"},{"key":"R6-20260119","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s00261-023-04060-3","article-title":"Crohn\u2019s disease inflammation severity assessment with iodine density from photon counting CT enterography: comparison with endoscopic histopathology","volume":"49","author":"Dane","year":"2024","journal-title":"Abdom Radiol"},{"key":"R7-20260119","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1148\/radiol.2021204405","article-title":"Crohn Disease Active inflammation assessment with iodine density from dual-energy CT enterography: comparison with histopathologic analysis","volume":"301","author":"Dane","year":"2021","journal-title":"Radiology"},{"key":"R8-20260119","doi-asserted-by":"crossref","first-page":"2219","DOI":"10.1007\/s00261-023-03923-z","article-title":"Crohn\u2019s disease phenotype analysis with iodine density from dual-energy CT enterography","volume":"48","author":"Dane","year":"2023","journal-title":"Abdom Radiol"},{"key":"R9-20260119","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1097\/RCT.0000000000001135","article-title":"Crohn disease prognostication with semiautomatic dual-energy computed tomography enterography-derived iodine density","volume":"45","author":"Dane","year":"2021","journal-title":"J Comput Assist Tomogr"},{"key":"R10-20260119","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1097\/RCT.0000000000000986","article-title":"Crohn\u2019s disease activity quantified by iodine density obtained from dual-energy computed tomography enterography","volume":"44","author":"Dane","year":"2020","journal-title":"J Comput Assist Tomogr"},{"key":"R11-20260119","doi-asserted-by":"crossref","first-page":"3406","DOI":"10.1007\/s00261-022-03605-2","article-title":"Crohn\u2019s disease active inflammation assessment with iodine density from dual-energy CT enterography: comparison with endoscopy and conventional interpretation","volume":"47","author":"Dane","year":"2022","journal-title":"Abdom Radiol"},{"key":"R12-20260119","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1093\/jrr\/rrad076","article-title":"Dual-energy computed tomography-based iodine concentration as a predictor of histopathological response to preoperative chemoradiotherapy for pancreatic cancer","volume":"64","author":"Ohira","year":"2023","journal-title":"J Radiat Res"},{"key":"R13-20260119","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-energy CT: principles, technical approaches, and clinical applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology"},{"key":"R14-20260119","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1007\/s00261-016-0842-4","article-title":"Comparison of virtual unenhanced CT images of the abdomen under different iodine flow rates","volume":"42","author":"Li","year":"2017","journal-title":"Abdom Radiol"},{"key":"R15-20260119","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1148\/radiol.212579","article-title":"First Clinical photon-counting detector CT system: technical evaluation","volume":"303","author":"Rajendran","year":"2022","journal-title":"Radiology"},{"key":"R16-20260119","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","article-title":"Photon-counting CT review","volume":"79","author":"Flohr","year":"2020","journal-title":"Phys Med"},{"key":"R17-20260119","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/RLI.0000000000000463","article-title":"Dose efficiency of quarter-millimeter photon-counting computed tomography: first-in-human results","volume":"53","author":"Pourmorteza","year":"2018","journal-title":"Invest Radiol"},{"key":"R18-20260119","doi-asserted-by":"crossref","first-page":"043503","DOI":"10.1117\/1.JMI.3.4.043503","article-title":"Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner","volume":"3","author":"Yu","year":"2016","journal-title":"J Med Imaging"},{"key":"R19-20260119","doi-asserted-by":"crossref","first-page":"3620","DOI":"10.1016\/j.acra.2024.02.006","article-title":"Photon counting computed tomography in rectal cancer: associations between iodine concentration, histopathology and treatment response: a pilot study","volume":"31","author":"Surov","year":"2024","journal-title":"Acad Radiol"},{"key":"R20-20260119","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1097\/SLA.0000000000000867","article-title":"Radiological and surgical implications of neoadjuvant treatment with FOLFIRINOX for locally advanced and borderline resectable pancreatic cancer","volume":"261","author":"Ferrone","year":"2015","journal-title":"Ann Surg"},{"key":"R21-20260119","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s00261-023-04042-5","article-title":"Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT","volume":"49","author":"Decker","year":"2024","journal-title":"Abdom Radiol"},{"key":"R22-20260119","doi-asserted-by":"crossref","first-page":"3149","DOI":"10.1007\/s00261-024-04298-5","article-title":"Inter-reader agreement of pancreatic adenocarcinoma resectability assessment with photon counting versus energy integrating detector CT","volume":"49","author":"Kim","year":"2024","journal-title":"Abdom Radiol"},{"key":"R23-20260119","doi-asserted-by":"crossref","first-page":"111437","DOI":"10.1016\/j.ejrad.2024.111437","article-title":"Pancreatic cyst prevalence and detection with photon counting CT compared with conventional energy integrating detector CT","volume":"175","author":"Dane","year":"2024","journal-title":"Eur J Radiol"},{"key":"R24-20260119","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1097\/RCT.0000000000000878","article-title":"Correlation between dual-energy computed tomography single scan and computed tomography perfusion for pancreatic cancer patients: initial experience","volume":"43","author":"Bao","year":"2019","journal-title":"J Comput Assist Tomogr"},{"key":"R25-20260119","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1097\/RLI.0000000000000176","article-title":"Correlation of quantitative dual-energy computed tomography iodine maps and abdominal computed tomography perfusion measurements: are single-acquisition dual-energy computed tomography iodine maps more than a reduced-dose surrogate of conventional computed tomography perfusion?","volume":"50","author":"Stiller","year":"2015","journal-title":"Invest Radiol"},{"key":"R26-20260119","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1148\/radiol.2019182561","article-title":"Perfusion CT to assess response to neoadjuvant chemotherapy and radiation therapy in pancreatic ductal adenocarcinoma: initial experience","volume":"292","author":"Hamdy","year":"2019","journal-title":"Radiology"},{"key":"R27-20260119","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1007\/s00261-017-1338-6","article-title":"Assessment of iodine uptake by pancreatic cancer following chemotherapy using dual-energy CT","volume":"43","author":"Kawamoto","year":"2018","journal-title":"Abdom Radiol"},{"key":"R28-20260119","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1080\/09553000601002324","article-title":"Hypoxia: importance in tumor biology, noninvasive measurement by imaging, and value of its measurement in the management of cancer therapy","volume":"82","author":"Tatum","year":"2006","journal-title":"Int J Radiat Biol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001771","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T14:00:38Z","timestamp":1768831238000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001771"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,10]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001771","relation":{},"ISSN":["1532-3145"],"issn-type":[{"value":"1532-3145","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,10]]},"assertion":[{"value":"2025-03-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}