{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T02:55:19Z","timestamp":1768877719011,"version":"3.49.0"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To evaluate an edge-on-irradiated silicon-based photon-counting detector CT (Deep Si-PCD-CT) prototype for quantification of iodine concentration and stability of HU values, as well as detectability of subtle features in simulated kidney parenchyma.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A phantom, simulating moderately and strongly enhancing kidney parenchyma (at 180 and 240 HU) inside a small, medium, and large patient (23, 30, 37\u00a0cm diameter, respectively), was scanned on a Deep Si-PCD-CT. Centered in the kidney parenchyma was a water-equivalent rod at 0 HU and a rod of 0.8\u00a0mg\/mL iodine concentration to simulate a benign, mildly enhancing cystic renal lesion, as well as a rod with a 2\u00a0mm septum and 5\u00a0mm mural nodule. Accuracy and stability of HU values were evaluated with repeated ROI measurements across consecutive slices, while the septum and nodule were identified on standard polychromatic clinical images and iodine maps. Images were reconstructed with a soft tissue kernel at 0.417- and 0.625-mm slice-thickness without additional denoising.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Deep Si-PCD-CT produced accurate HU value measurements for water, intralesional iodine content, and renal parenchymal enhancement. The HU values were similarly variable from the ground truth values as compared with measurements from a commercial energy-integrating detector CT. The nodule and septum inside the phantom were successfully identified using the new Deep Si-PCD-CT prototype, while they were difficult to identify using the standard EID-CT at clinical window-level settings. The iodine maps created from the photon-counting detector CT displayed both the nodule and the septum well, facilitating quick identification.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Deep Si-PCD-CT is a promising tool for the accurate measurement of HU values, as well as the detection of subtle features of complexity in cystic renal lesions. It has the potential to improve the diagnosis and management of cystic renal lesions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001773","type":"journal-article","created":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T12:00:42Z","timestamp":1751457642000},"page":"20-27","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Novel Edge-on-irradiated Si-based Photon-counting Detector CT for the Characterization of Cystic Renal Lesions"],"prefix":"10.1097","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3598-7082","authenticated-orcid":false,"given":"Fides R.","family":"Schwartz","sequence":"first","affiliation":[{"name":"Department of Radiology, Brigham and Women\u2019s Hospital, Boston, MA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhye","family":"Yin","sequence":"additional","affiliation":[{"name":"GE Healthcare, Waukesha, WI"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xue","family":"Rui","sequence":"additional","affiliation":[{"name":"GE Healthcare, Waukesha, WI"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steve","family":"Bache","sequence":"additional","affiliation":[{"name":"Department of Radiology, Duke University Hospital, WI"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ehsan","family":"Samei","sequence":"additional","affiliation":[{"name":"Duke University Hospital, Durham, NC"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Grant M.","family":"Stevens","sequence":"additional","affiliation":[{"name":"GE Healthcare, Waukesha, WI"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aria M.","family":"Salyapongse","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Madison, Wisconsin, Madison, WI"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy P.","family":"Szczykutowicz","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Madison, Wisconsin, Madison, WI"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniele","family":"Marin","sequence":"additional","affiliation":[{"name":"Department of Radiology, Duke University Hospital, WI"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2026,1]]},"reference":[{"key":"R1-20260119","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1007\/s00261-016-0761-4","article-title":"Cystic renal masses","volume":"41","author":"Hindman","year":"2016","journal-title":"Abdom Radiol"},{"key":"R2-20260119","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1148\/radiol.2019182646","article-title":"Bosniak Classification of Cystic Renal Masses, Version 2019: an update proposal and needs assessment","volume":"292","author":"Silverman","year":"2019","journal-title":"Radiology"},{"key":"R3-20260119","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.jacr.2014.12.012","article-title":"ACR Appropriateness Criteria indeterminate renal mass","volume":"12","author":"Heilbrun","year":"2015","journal-title":"J Am Coll Radiol"},{"key":"R4-20260119","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.jcct.2012.04.005","article-title":"State-of-the-art in CT hardware and scan modes for cardiovascular CT","volume":"6","author":"Halliburton","year":"2012","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R5-20260119","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1097\/RLI.0000000000000873","article-title":"Effective spatial resolution of photon counting CT for imaging of trabecular structures is superior to conventional clinical CT and similar to high resolution peripheral CT","volume":"57","author":"Thomsen","year":"2022","journal-title":"Invest Radiol"},{"key":"R6-20260119","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1148\/radiol.14140876","article-title":"Dual-energy multidetector cT for the characterization of incidental adrenal nodules: diagnostic performance of contrast enhanced material density analysis","volume":"274","author":"Mileto","year":"2015","journal-title":"Radiology"},{"key":"R7-20260119","doi-asserted-by":"crossref","first-page":"W466","DOI":"10.2214\/AJR.13.11450","article-title":"Accuracy of contrast-enhanced dual-energy MDCT for the assessment of iodine uptake in renal lesions","volume":"202","author":"Mileto","year":"2014","journal-title":"AJR Am J Roentgenol"},{"key":"R8-20260119","first-page":"043502","article-title":"Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning","volume":"6","author":"da Silva","year":"2019","journal-title":"J Med Imaging (Bellingham"},{"key":"R9-20260119","first-page":"124630D","article-title":"Intra-detector x-ray scatterings in edge-on irradiated silicon photon counting CT: how to harvest information from scattered photons","volume":"12463","author":"Li","year":"2023","journal-title":"SPIE"},{"key":"R10-20260119","doi-asserted-by":"crossref","first-page":"539","DOI":"10.2214\/AJR.23.29463","article-title":"CT number accuracy and association with object size: a phantom study comparing energy-integrating detector CT and deep silicon photon-counting detector CT","volume":"221","author":"Salyapongse","year":"2023","journal-title":"AJR Am J Roentgenol"},{"key":"R11-20260119","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1118\/1.4939128","article-title":"Technical note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging","volume":"43","author":"Michalak","year":"2016","journal-title":"Med Phys"},{"key":"R12-20260119","doi-asserted-by":"crossref","first-page":"7216","DOI":"10.1088\/1361-6560\/aa8103","article-title":"Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets","volume":"62","author":"Leng","year":"2017","journal-title":"Phys Med Biol"},{"key":"R13-20260119","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-Energy CT: principles, technical approaches, and clinical applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology"},{"key":"R14-20260119","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.acra.2023.06.031","article-title":"Initial clinical images from a second-generation prototype silicon-based photon-counting computed tomography system","volume":"31","author":"Almqvist","year":"2024","journal-title":"Acad Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001773","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T14:00:36Z","timestamp":1768831236000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001773"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,2]]},"references-count":14,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001773","relation":{},"ISSN":["1532-3145"],"issn-type":[{"value":"1532-3145","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,2]]},"assertion":[{"value":"2024-10-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}