{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T20:02:13Z","timestamp":1762891333839,"version":"3.45.0"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the scan timing adequacy for the pancreatic phase between fixed and tailored scan delay in the pancreatic protocol CT with a bolus-tracking technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      This retrospective study included patients who underwent pancreatic protocol CT using a fixed scan delay of 20 s from January 2020 to November 2022 (conventional group) and those using a tailored scan delay from January 2023 to July 2024 (tailored group). Tailored scan delay was identified to be the same as the time from contrast injection to reaching to trigger threshold of 100\u00a0HU (Time\n                      <jats:sub>TRIG<\/jats:sub>\n                      ). The scan delay ratio (SDR) was calculated by dividing the scan delay by Time\n                      <jats:sub>TRIG<\/jats:sub>\n                      . Two radiologists assessed the scan timing adequacy for the pancreatic phase and classified it into 3 categories: early, appropriate, and late. The SDR and scan timing adequacy were compared between the conventional and tailored groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      This study involved 128 patients (75 men; median age, 71\u00a0y), including 63 and 65 in the conventional and tailored groups, respectively. The median SDR was significantly different between the two groups (1.2 and 1.0 in the conventional and tailored groups;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). The proportion of appropriate scan timing for the pancreatic phase was higher in the tailored group (55\/65; 84%) than in the conventional group (47\/63; 75%); however, no statistical significance was observed (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.36).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The tailored scan delay tended to provide a higher rate of appropriate scan timing for the pancreatic phase compared with the conventional protocol using a fixed scan delay of 20 s.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001774","type":"journal-article","created":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T20:00:14Z","timestamp":1749240014000},"page":"891-895","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Fixed Versus Tailored Scan Delay for Pancreatic Phase Acquisition: Comparison of Scan Timing Adequacy"],"prefix":"10.1097","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3611-4790","authenticated-orcid":false,"given":"Yoshifumi","family":"Noda","sequence":"first","affiliation":[{"name":"Department of Radiology, Gifu University, Gifu, Japan"},{"name":"Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukiko","family":"Takai","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gifu University, Gifu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Asano","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gifu University, Gifu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuyuki","family":"Kawai","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gifu University, Gifu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuro","family":"Kaga","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gifu University, Gifu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akio","family":"Ito","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gifu University, Gifu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiharu","family":"Miyoshi","sequence":"additional","affiliation":[{"name":"Department of Radiology Services, Gifu University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fuminori","family":"Hyodo","sequence":"additional","affiliation":[{"name":"Department of Pharmacology, Graduate School of Medicine, Gifu University"},{"name":"Center for One Medicine Innovative Translational Research (COMIT), Institute for Advanced Study, Gifu University, Gifu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Kato","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gifu University, Gifu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masayuki","family":"Matsuo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gifu University, Gifu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,6,6]]},"reference":[{"key":"R1-20251111","doi-asserted-by":"crossref","first-page":"3035","DOI":"10.1007\/s00261-018-1579-z","article-title":"Utility of the portal venous phase for diagnosing pancreatic necrosis in acute pancreatitis using the CT severity index","volume":"43","author":"Noda","year":"2018","journal-title":"Abdom Radiol (NY)"},{"key":"R3-20251111","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1148\/radiol.2019190144","article-title":"Determining malignant potential of intraductal papillary mucinous neoplasm of the pancreas: CT versus MRI by using revised 2017 International Consensus Guidelines","volume":"293","author":"Lee","year":"2019","journal-title":"Radiology"},{"key":"R4-20251111","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1148\/radiology.220.1.r01jl1897","article-title":"Multi-detector row helical CT of the pancreas: effect of contrast-enhanced multiphasic imaging on enhancement of the pancreas, peripancreatic vasculature, and pancreatic adenocarcinoma","volume":"220","author":"McNulty","year":"2001","journal-title":"Radiology"},{"key":"R5-20251111","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1148\/radiology.207.3.9609887","article-title":"Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model","volume":"207","author":"Bae","year":"1998","journal-title":"Radiology"},{"key":"R6-20251111","doi-asserted-by":"crossref","first-page":"751","DOI":"10.2214\/AJR.06.0372","article-title":"MDCT of the pancreas: optimizing scanning delay with a bolus-tracking technique for pancreatic, peripancreatic vascular, and hepatic contrast enhancement","volume":"188","author":"Kondo","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"R7-20251111","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1007\/s00261-009-9560-5","article-title":"Pancreatic adenocarcinoma: a comparison of automatic bolus tracking and empirical scan delay","volume":"35","author":"Fukukura","year":"2010","journal-title":"Abdom Imaging"},{"key":"R8-20251111","doi-asserted-by":"crossref","first-page":"20210315","DOI":"10.1259\/bjr.20210315","article-title":"Optimized scan delay for late hepatic arterial or pancreatic parenchymal phase in dynamic contrast-enhanced computed tomography with bolus-tracking method","volume":"94","author":"Noda","year":"2021","journal-title":"Br J Radiol"},{"key":"R9-20251111","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1148\/radiol.2262011593","article-title":"Hepatic arterial phase MR imaging with automated bolus-detection three-dimensional fast gradient-recalled-echo sequence: comparison with test-bolus method","volume":"226","author":"Hussain","year":"2003","journal-title":"Radiology"},{"key":"R10-20251111","doi-asserted-by":"crossref","first-page":"110685","DOI":"10.1016\/j.ejrad.2022.110685","article-title":"Comparison of image quality and pancreatic ductal adenocarcinoma conspicuity between the low-kVp and dual-energy CT reconstructed with deep-learning image reconstruction algorithm","volume":"159","author":"Noda","year":"2023","journal-title":"Eur J Radiol"},{"key":"R11-20251111","doi-asserted-by":"crossref","first-page":"E46","DOI":"10.1007\/s10406-005-0165-y","article-title":"Scan and contrast administration principles of MDCT","volume":"15","author":"Bae","year":"2005","journal-title":"Eur Radiol"},{"key":"R12-20251111","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/s12194-010-0105-y","article-title":"Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography","volume":"4","author":"Yamaguchi","year":"2011","journal-title":"Radiol Phys Technol"},{"key":"R13-20251111","doi-asserted-by":"crossref","first-page":"W25","DOI":"10.2214\/AJR.04.1878","article-title":"MDCT of the liver and hypervascular hepatocellular carcinomas: optimizing scan delays for bolus-tracking techniques of hepatic arterial and portal venous phases","volume":"187","author":"Goshima","year":"2006","journal-title":"AJR Am J Roentgenol"},{"key":"R14-20251111","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1177\/0284185113485571","article-title":"Optimal scan timing of hepatic arterial-phase imaging of hypervascular hepatocellular carcinoma determined by multiphasic fast CT imaging technique","volume":"54","author":"Kagawa","year":"2013","journal-title":"Acta Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001774","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T20:00:20Z","timestamp":1762891220000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001774"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,6]]},"references-count":13,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001774","relation":{},"ISSN":["0363-8715","1532-3145"],"issn-type":[{"type":"print","value":"0363-8715"},{"type":"electronic","value":"1532-3145"}],"subject":[],"published":{"date-parts":[[2025,6,6]]},"assertion":[{"value":"2025-02-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-13","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}