{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T17:44:37Z","timestamp":1791481477123,"version":"4.3.4"},"reference-count":54,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Photon-counting computed tomography (PCCT) is a new imaging technology that has advanced diagnostic imaging by offering improved spatial and contrast resolution as well as novel spectral imaging capabilities. Unlike conventional CT, which uses energy-integrating detectors, PCCT employs photon-counting detectors that directly measure individual photon energies, enabling applications such as virtual monochromatic imaging (VMI) and material decomposition. These innovations allow for artifact reduction, better visualization of fine anatomic structures, and improved diagnostic accuracy, all while reducing radiation dose. This review explores select applications of PCCT in neuroimaging, focusing on the brain, temporal bone, and spine. In the brain, we discuss how PCCT demonstrates superior performance for evaluating aneurysms, metallic prostheses, and vessel stenosis, offering enhanced visualization of vascular structures and minimizing artifacts. For temporal bone imaging, we review assessment of both complex anatomy and potentially subtle pathologies such as otosclerosis, as well as visualization of implants like cochlear devices and their intricate components. In spinal imaging, we explore how PCCT improves precise detection of causes of cerebrospinal fluid leaks, improves localization of tiny vessels such as the artery of Adamkiewicz and spinal dural arteriovenous fistulas, and reduces metal artifacts associated with postoperative hardware. PCCT addresses limitations of conventional CT while unlocking new diagnostic possibilities across neuroimaging applications. As clinical adoption of PCCT grows, ongoing research and development will refine imaging protocols and expand its utility. The accumulating evidence underscores PCCT\u2019s transformative potential to improve diagnostic confidence in neuroimaging and beyond.<\/jats:p>","DOI":"10.1097\/rct.0000000000001776","type":"journal-article","created":{"date-parts":[[2025,6,26]],"date-time":"2025-06-26T08:00:10Z","timestamp":1750924810000},"page":"46-53","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Neuroimaging Applications of Photon-counting CT"],"prefix":"10.1097","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2386-7849","authenticated-orcid":false,"given":"Siddhant","family":"Dogra","sequence":"first","affiliation":[{"name":"Department of Radiology, New York University Langone Health, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajay","family":"Madhavan","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic, Rochester, MN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gul","family":"Moonis","sequence":"additional","affiliation":[{"name":"Department of Radiology, New York University Langone Health, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,1]]},"reference":[{"key":"R1-20260119","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1097\/RLI.0000000000000980","article-title":"Technical basics and clinical benefits of photon-counting CT","volume":"58","author":"Flohr","year":"2023","journal-title":"Invest Radiol"},{"key":"R2-20260119","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.diii.2024.09.002","article-title":"Photon-counting CT systems: a technical review of current clinical possibilities","volume":"106","author":"Greffier","year":"2025","journal-title":"Diagn Interv Imaging"},{"key":"R3-20260119","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon-counting CT: technical principles and clinical prospects","volume":"289","author":"Willemink","year":"2018","journal-title":"Radiology"},{"key":"R4-20260119","doi-asserted-by":"crossref","first-page":"112","DOI":"10.3390\/jimaging8040112","article-title":"Spectral photon-counting computed tomography: a review on technical principles and clinical applications","volume":"8","author":"Tortora","year":"2022","journal-title":"J Imaging"},{"key":"R5-20260119","doi-asserted-by":"crossref","first-page":"2362","DOI":"10.1016\/j.acra.2023.05.029","article-title":"Photon counting CT: technical principles, clinical applications, and future prospects","volume":"30","author":"Wu","year":"2023","journal-title":"Acad Radiol"},{"key":"R6-20260119","first-page":"tqae226","article-title":"A review of applications of photon-counting computed tomography in head and neck imaging","author":"Dogra","year":"2024","journal-title":"Br J Radiol"},{"key":"R7-20260119","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.3174\/ajnr.A8265","article-title":"Photon-counting CT in the head and neck: current applications and future prospects","volume":"45","author":"Benson","year":"2024","journal-title":"AJNR Am J Neuroradiol"},{"key":"R8-20260119","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1093\/bjr\/tqae058","article-title":"High yield clinical applications for photon counting CT in neurovascular imaging","volume":"97","author":"Madhavan","year":"2024","journal-title":"Br J Radiol"},{"key":"R9-20260119","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/j.rcl.2023.05.009","article-title":"Neuroradiology applications of dual and multi-energy computed tomography","volume":"61","author":"Jarunnarumol","year":"2023","journal-title":"Radiol Clin North Am"},{"key":"R10-20260119","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ejrad.2011.05.003","article-title":"Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms","volume":"81","author":"Luo","year":"2012","journal-title":"Eur J Radiol"},{"key":"R11-20260119","doi-asserted-by":"crossref","first-page":"205019","DOI":"10.1088\/1361-6560\/ac155e","article-title":"Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience","volume":"66","author":"Rajendran","year":"2021","journal-title":"Phys Med Biol"},{"key":"R12-20260119","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.3174\/ajnr.A8350","article-title":"Neurovascular imaging with ultra-high-resolution photon-counting CT: preliminary findings on image-quality evaluation","volume":"45","author":"T\u00f3th","year":"2024","journal-title":"AJNR Am J Neuroradiol"},{"key":"R13-20260119","doi-asserted-by":"crossref","first-page":"e48","DOI":"10.1161\/STROKEAHA.123.046174","article-title":"Photon-counting detector CT angiography in cervical artery dissection","volume":"55","author":"Keser","year":"2024","journal-title":"Stroke"},{"key":"R14-20260119","doi-asserted-by":"crossref","first-page":"5309","DOI":"10.1007\/s00330-023-09596-y","article-title":"Clinical applications of photon counting detector CT","volume":"33","author":"McCollough","year":"2023","journal-title":"Eur Radiol"},{"key":"R15-20260119","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1109\/TRPMS.2020.3020212","article-title":"Photon counting CT: clinical applications and future developments","volume":"5","author":"Hsieh","year":"2021","journal-title":"IEEE Trans Radiat Plasma Med Sci"},{"key":"R16-20260119","doi-asserted-by":"crossref","DOI":"10.1136\/jnis-2024-022041","article-title":"Ultra-high resolution CT angiography for the assessment of intracranial stents and flow diverters using photon counting detector CT","author":"Ludovichetti","year":"2025","journal-title":"J Neurointerv Surg"},{"key":"R17-20260119","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1007\/s00330-022-09073-y","article-title":"Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT\u2014in vitro comparison of a standard brain imaging protocol","volume":"33","author":"Schmitt","year":"2023","journal-title":"Eur Radiol"},{"key":"R18-20260119","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1097\/RLI.0000000000000984","article-title":"Advanced neuroimaging with photon-counting detector CT","volume":"58","author":"Abel","year":"2023","journal-title":"Invest Radiol"},{"key":"R19-20260119","doi-asserted-by":"crossref","first-page":"24","DOI":"10.3390\/jcm13082436","article-title":"Potential benefits of photon-counting CT in dental imaging: a narrative review","volume":"13","author":"Zanon","year":"2024","journal-title":"J Clin Med"},{"key":"R20-20260119","doi-asserted-by":"crossref","first-page":"e328","DOI":"10.1161\/STROKEAHA.124.049448","article-title":"Evaluation of intracranial fusiform aneurysm after flow diverter treatment at photon-counting CT","volume":"55","author":"Wei","year":"2024","journal-title":"Stroke"},{"key":"R21-20260119","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1007\/s00234-007-0244-y","article-title":"Multidetector-row CT angiography in the study of atherosclerotic carotid arteries","volume":"49","author":"Saba","year":"2007","journal-title":"Neuroradiology"},{"key":"R22-20260119","doi-asserted-by":"crossref","first-page":"20200714","DOI":"10.1259\/bjr.20200714","article-title":"The effects of the skull on CT imaging of the brain: a skull and brain phantom study","volume":"94","author":"Cauley","year":"2021","journal-title":"Br J Radiol"},{"key":"R23-20260119","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/RLI.0000000000000418","article-title":"Photon-counting computed tomography for vascular imaging of the head and neck: first in vivo human results","volume":"53","author":"Symons","year":"2018","journal-title":"Invest Radiol"},{"key":"R24-20260119","doi-asserted-by":"crossref","first-page":"185015","DOI":"10.1088\/1361-6560\/ab32fe","article-title":"Impacts of photon counting CT to maximum intensity projection (MIP) images of cerebral CT angiography: theoretical and experimental studies","volume":"64","author":"Harvey","year":"2019","journal-title":"Phys Med Biol"},{"key":"R25-20260119","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/RLI.0000000000000853","article-title":"Photon-counting detector CT-based vascular calcium removal algorithm: assessment using a cardiac motion phantom","volume":"57","author":"Allmendinger","year":"2022","journal-title":"Invest Radiol"},{"key":"R26-20260119","doi-asserted-by":"crossref","first-page":"e230545","DOI":"10.1148\/radiol.230545","article-title":"Coronary artery calcium scoring using virtual versus true noncontrast images from photon-counting coronary CT angiography","volume":"310","author":"Haag","year":"2024","journal-title":"Radiology"},{"key":"R27-20260119","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1055\/s-0041-1741006","article-title":"High-resolution CT imaging of the temporal bone: a cadaveric specimen study","volume":"83","author":"Pham","year":"2022","journal-title":"J Neurol Surg B Skull Base"},{"key":"R28-20260119","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1097\/RCT.0000000000001464","article-title":"High spatial-resolution skull base imaging with photon-counting computed tomography and energy-integrating computed tomography: a comparative phantom study","volume":"47","author":"Rajagopal","year":"2023","journal-title":"J Comput Assist Tomogr"},{"key":"R29-20260119","doi-asserted-by":"crossref","first-page":"1857","DOI":"10.3174\/ajnr.A8359","article-title":"Comprehensive review of external and middle ear anatomy on photon-counting CT","volume":"45","author":"Rao","year":"2024","journal-title":"AJNR Am J Neuroradiol"},{"key":"R30-20260119","first-page":"862","article-title":"Comprehensive review of inner ear anatomy on photon-counting CT","volume":"46","author":"Rao","year":"2025","journal-title":"AJNR Am J Neuroradiol"},{"key":"R31-20260119","doi-asserted-by":"crossref","first-page":"e240028","DOI":"10.1148\/rg.240028","article-title":"Ultra-high-resolution temporal bone anatomy using photon-counting CT: added value of improved spatial resolution","volume":"44","author":"Ansari","year":"2024","journal-title":"Radiographics"},{"key":"R32-20260119","doi-asserted-by":"crossref","first-page":"579","DOI":"10.3174\/ajnr.A7452","article-title":"A new frontier in temporal bone imaging: photon-counting detector CT demonstrates superior visualization of critical anatomic structures at reduced radiation dose","volume":"43","author":"Benson","year":"2022","journal-title":"AJNR Am J Neuroradiol"},{"key":"R33-20260119","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1186\/s13244-023-01467-w","article-title":"Photon-counting CT allows better visualization of temporal bone structures in comparison with current generation multi-detector CT","volume":"14","author":"Hermans","year":"2023","journal-title":"Insights Imaging"},{"key":"R34-20260119","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1097\/RLI.0000000000000901","article-title":"Spectral shaping via tin prefiltration in ultra-high-resolution photon-counting and energy-integrating detector CT of the temporal bone","volume":"57","author":"Grunz","year":"2022","journal-title":"Invest Radiol"},{"key":"R35-20260119","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/RLI.0000000000000614","article-title":"Dose reduction for sinus and temporal bone imaging using photon-counting detector CT with an additional tin filter","volume":"55","author":"Rajendran","year":"2020","journal-title":"Invest Radiol"},{"key":"R36-20260119","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1007\/s11604-023-01485-0","article-title":"Evaluation of the ear ossicles with photon-counting detector CT","volume":"42","author":"Takahashi","year":"2024","journal-title":"Jpn J Radiol"},{"key":"R37-20260119","doi-asserted-by":"crossref","first-page":"e1205","DOI":"10.1097\/MAO.0000000000003682","article-title":"Photon-counting detector CT for temporal bone imaging: up to three times the resolution at half the radiation dose","volume":"43","author":"Macielak","year":"2022","journal-title":"Otol Neurotol"},{"key":"R38-20260119","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1007\/s11547-019-00997-y","article-title":"Identification of residual-recurrent cholesteatoma in operated ears: diagnostic accuracy of dual-energy CT and MRI","volume":"124","author":"Foti","year":"2019","journal-title":"Radiol Med"},{"key":"R39-20260119","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.3390\/tomography8040136","article-title":"Photon-counting detector CT virtual monoengergetic images for cochlear implant visualization\u2014a head to head comparison to energy-integrating detector CT","volume":"8","author":"Waldeck","year":"2022","journal-title":"Tomography"},{"key":"R40-20260119","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1097\/MAO.0000000000004221","article-title":"The photon-counting CT enters the field of cochlear implantation: comparison to angiography DynaCT and conventional multislice CT","volume":"45","author":"Rak","year":"2024","journal-title":"Otol Neurotol"},{"key":"R41-20260119","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1007\/s00234-019-02207-y","article-title":"Artery of Adamkiewicz: a meta-analysis of anatomical characteristics","volume":"61","author":"Taterra","year":"2019","journal-title":"Neuroradiology"},{"key":"R42-20260119","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1097\/BRS.0000000000000909","article-title":"The impact of preoperative angiographic identification of the artery of adamkiewicz on surgical decision making in patients undergoing thoracolumbar corpectomy","volume":"40","author":"Fanous","year":"2015","journal-title":"Spine (Phila Pa 1976)"},{"key":"R43-20260119","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1007\/s10143-023-02242-7","article-title":"Usefulness of time-resolved MR angiography in spinal dural arteriovenous fistula (SDAVF)\u2014a systematic review and meta-analysis","volume":"47","author":"W\u00f3jtowicz","year":"2023","journal-title":"Neurosurg Rev"},{"key":"R44-20260119","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1161\/STROKEAHA.124.049475","article-title":"Accurate detection of spinal Dural arteriovenous fistula with spinal photon-counting computed tomography angiography: a report of two cases","volume":"56","author":"He","year":"2025","journal-title":"Stroke"},{"key":"R45-20260119","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.3174\/ajnr.A8299","article-title":"Myelographic techniques for the localization of CSF-venous fistulas: updates in 2024","volume":"45","author":"Madhavan","year":"2024","journal-title":"AJNR Am J Neuroradiol"},{"key":"R46-20260119","first-page":"754","article-title":"Decubitus CT myelography for detecting subtle CSF leaks in spontaneous intracranial hypotension","volume":"40","author":"Kranz","year":"2019","journal-title":"AJNR Am J Neuroradiol"},{"key":"R47-20260119","doi-asserted-by":"crossref","first-page":"740","DOI":"10.3174\/ajnr.A7887","article-title":"Utility of photon-counting detector CT myelography for the detection of CSF-venous fistulas","volume":"44","author":"Madhavan","year":"2023","journal-title":"AJNR Am J Neuroradiol"},{"key":"R48-20260119","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.3174\/ajnr.A8040","article-title":"Diagnostic performance of decubitus photon-counting detector CT myelography for the detection of CSF-venous fistulas","volume":"44","author":"Madhavan","year":"2023","journal-title":"AJNR Am J Neuroradiol"},{"key":"R49-20260119","doi-asserted-by":"crossref","first-page":"96","DOI":"10.3174\/ajnr.A8097","article-title":"Application of a denoising high-resolution deep convolutional neural network to improve conspicuity of CSF-venous fistulas on photon-counting CT myelography","volume":"45","author":"Madhavan","year":"2023","journal-title":"AJNR Am J Neuroradiol"},{"key":"R50-20260119","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1212\/WNL.0000000000002986","article-title":"A classification system of spontaneous spinal CSF leaks","volume":"87","author":"Schievink","year":"2016","journal-title":"Neurology"},{"key":"R51-20260119","doi-asserted-by":"crossref","first-page":"1897","DOI":"10.1007\/s00234-022-02985-y","article-title":"Lateral decubitus dynamic CT myelography for fast cerebrospinal fluid leak localization","volume":"64","author":"Madhavan","year":"2022","journal-title":"Neuroradiology"},{"key":"R52-20260119","doi-asserted-by":"crossref","first-page":"668","DOI":"10.3174\/ajnr.A8179","article-title":"Benefits of photon-counting CT myelography for localization of Dural tears in spontaneous intracranial hypotension","volume":"45","author":"Madhavan","year":"2024","journal-title":"AJNR Am J Neuroradiol"},{"key":"R53-20260119","doi-asserted-by":"crossref","first-page":"5578","DOI":"10.1007\/s00330-023-09511-5","article-title":"Photon-Counting Computed Tomography (PC-CT) of the spine: impact on diagnostic confidence and radiation dose","volume":"33","author":"Rau","year":"2023","journal-title":"Eur Radiol"},{"key":"R54-20260119","doi-asserted-by":"crossref","first-page":"110946","DOI":"10.1016\/j.ejrad.2023.110946","article-title":"Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets","volume":"165","author":"Popp","year":"2023","journal-title":"Eur J Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001776","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T14:00:42Z","timestamp":1768831242000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001776"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,13]]},"references-count":54,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001776","relation":{},"ISSN":["1532-3145"],"issn-type":[{"value":"1532-3145","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,13]]},"assertion":[{"value":"2025-01-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-20","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}