{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:32:50Z","timestamp":1786120370507,"version":"build-2736575974"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Photon-counting detector computed tomography (PCD-CT) is an emerging imaging modality that offers substantial benefits in pediatric imaging, including improved spatial and contrast resolution, reduced radiation exposure, and advanced spectral imaging capabilities. This review summarizes current evidence across key pediatric body systems. In neurological imaging, PCD-CT has demonstrated superior image quality in evaluating fine temporal bone structures and reduced radiation dose, particularly in children under 6. Cardiovascular applications benefit from high-pitch dual-source acquisition and spectral imaging, improving delineation of congenital heart defects with reduced radiation and, potentially, contrast dose. Thoracic studies highlight significant radiation dose reduction while preserving diagnostic image quality in diseases such as cystic fibrosis. In abdominal imaging, PCD-CT allows consistent, high-quality imaging with simplified protocols and reduced iodinated contrast requirements, especially in challenging tasks like biliary structure visualization. Despite promising phantom and retrospective studies, research in musculoskeletal imaging remains sparse, with only limited pediatric data available. Nonetheless, PCD-CT shows potential for quantitative bone assessment, a critical application for children with chronic disease or at risk for osteoporosis. While early data are promising, significant gaps remain regarding protocol optimization, age-stratified performance, and the full utility of spectral reconstructions in pediatric imaging. Continued investigation is necessary to establish evidence-based guidelines and unlock the full clinical potential of PCD-CT in pediatric radiology.<\/jats:p>","DOI":"10.1097\/rct.0000000000001810","type":"journal-article","created":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T19:00:08Z","timestamp":1759777208000},"page":"65-72","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Photon-Counting CT in Children: A Literature Review"],"prefix":"10.1097","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1733-7489","authenticated-orcid":false,"given":"Felicia L.","family":"Pasadyn","sequence":"first","affiliation":[{"name":"NYU Grossman School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander M.","family":"El-Ali","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,1]]},"reference":[{"key":"R1-20260119","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1259\/bjr.20230189","article-title":"Potential benefits of photon counting detector computed tomography in pediatric imaging","volume":"96","author":"Horst","year":"2023","journal-title":"Br J Radiol"},{"key":"R2-20260119","doi-asserted-by":"crossref","first-page":"580","DOI":"10.2214\/AJR.22.28391","article-title":"Pediatric applications of photon-counting detector CT","volume":"220","author":"Cao","year":"2022","journal-title":"AJR Am J Roentgenol"},{"key":"R3-20260119","doi-asserted-by":"crossref","first-page":"2583","DOI":"10.1007\/s00381-023-06041-9","article-title":"Revolutionizing pediatric neuroimaging: the era of CT, MRI, and beyond","volume":"39","author":"Ryan","year":"2023","journal-title":"Child S Nervous System"},{"key":"R4-20260119","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/RLI.0000000000000614","article-title":"Dose reduction for sinus and temporal bone imaging using Photon-Counting Detector CT with an additional TIN filter","volume":"55","author":"Rajendran","year":"2019","journal-title":"Invest Radiol"},{"key":"R5-20260119","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.3174\/ajnr.A8276","article-title":"Comparison of image quality and radiation dose in pediatric temporal bone CT using Photon-Counting Detector CT and Energy-Integrating Detector CT","volume":"45","author":"Lee","year":"2024","journal-title":"AJNR Am J Neuroradiol"},{"key":"R6-20260119","doi-asserted-by":"crossref","DOI":"10.1093\/bjro\/tzae015","article-title":"Unlocking the Potential of Photon Counting Detector CT (PCD-CT) for Paediatric Imaging: a pictorial essay","volume":"6","author":"Aliukonyte","year":"2023","journal-title":"BJR|Open"},{"key":"R7-20260119","article-title":"Role of photon-counting computed tomography in pediatric cardiovascular imaging","volume":"14","author":"Arachchige","year":"2024","journal-title":"World J Clin Pediatr"},{"key":"R8-20260119","doi-asserted-by":"crossref","DOI":"10.1093\/radadv\/umae012","article-title":"Photon counting detector computed tomography in pediatric cardiothoracic CT imaging","volume":"1","author":"Siegel","year":"2024","journal-title":"Radiol Adv"},{"key":"R9-20260119","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.jcct.2022.04.004","article-title":"Cardiovascular computed tomography in pediatric congenital heart disease: a state of the art review","volume":"16","author":"Cohen","year":"2022","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R10-20260119","doi-asserted-by":"crossref","first-page":"e223088","DOI":"10.1148\/radiol.223088","article-title":"Photon-counting versus dual-source CT of congenital heart defects in neonates and infants: initial experience","volume":"307","author":"Dirrichs","year":"2023","journal-title":"Radiology"},{"key":"R11-20260119","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1007\/s00247-024-05939-z","article-title":"Photon-counting computed tomography for paediatric congenital heart defects yields images of high diagnostic quality with low radiation doses at both 70 kV and 90 kV","volume":"54","author":"St\u00e5lhammar","year":"2024","journal-title":"Pediatr Radiol"},{"key":"R12-20260119","doi-asserted-by":"crossref","first-page":"e231741","DOI":"10.1148\/radiol.231741","article-title":"Multi-institutional protocol guidance for pediatric photon-counting CT","volume":"311","author":"Horst","year":"2024","journal-title":"Radiology"},{"key":"R13-20260119","doi-asserted-by":"crossref","first-page":"1984","DOI":"10.1007\/s00247-024-06078-1","article-title":"Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT","volume":"54","author":"El-Ali","year":"2024","journal-title":"Pediatr Radiol"},{"key":"R15-20260119","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.jcct.2023.03.004","article-title":"Quality improvement in pediatric and congenital cardiac CT: a call to action","volume":"17","author":"Chelliah","year":"2023","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R16-20260119","doi-asserted-by":"crossref","first-page":"2660","DOI":"10.1002\/ppul.25446","article-title":"Thoracic CTA in infants and young children: Image quality of dual-source CT (DSCT) with high-pitch spiral scan mode (turbo flash spiral mode) with or without general anesthesia with free-breathing technique","volume":"56","author":"Tivnan","year":"2021","journal-title":"Pediatr Pulmonol"},{"key":"R17-20260119","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1007\/s00247-018-4295-5","article-title":"Ultrafast pediatric chest computed tomography: comparison of free-breathing vs. breath-hold imaging with and without anesthesia in young children","volume":"49","author":"Kino","year":"2019","journal-title":"Pediatr Radiol"},{"key":"R18-20260119","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1007\/s00247-022-05584-4","article-title":"Low dose pediatric chest computed tomography on a photon counting detector system\u2014initial clinical experience","volume":"53","author":"Tsiflikas","year":"2023","journal-title":"Pediatr Radiol"},{"key":"R19-20260119","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1007\/s00247-022-05574-6","article-title":"Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs","volume":"53","author":"Horst","year":"2023","journal-title":"Pediatr Radiol"},{"key":"R20-20260119","doi-asserted-by":"crossref","first-page":"363","DOI":"10.2214\/AJR.23.29077","article-title":"Comparison of radiation dose and image quality of pediatric high-resolution chest CT between photon-counting detector CT and energy-integrated detector CT: a matched study","volume":"221","author":"Siegel","year":"2023","journal-title":"AJR Am J Roentgenol"},{"key":"R21-20260119","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1097\/RLI.0000000000000634","article-title":"A universal protocol for abdominal CT examinations performed on a Photon-Counting Detector CT System: a feasibility study","volume":"55","author":"Zhou","year":"2020","journal-title":"Invest Radiol"},{"key":"R22-20260119","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1007\/s00247-025-06209-2","article-title":"Photon-counting CT yields superior abdominopelvic image quality at lower radiation and iodinated contrast doses","volume":"55","author":"Schwartz","year":"2025","journal-title":"Pediatr Radiol"},{"key":"R23-20260119","doi-asserted-by":"crossref","first-page":"551","DOI":"10.2214\/AJR.22.28418","article-title":"Photon-Counting Detector CT for musculoskeletal imaging: a clinical perspective","volume":"220","author":"Baffour","year":"2022","journal-title":"AJR Am J Roentgenol"},{"key":"R24-20260119","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1053\/j.ro.2024.05.003","article-title":"Photon-Counting CT in musculoskeletal imaging\u201410 key questions answered","volume":"59","author":"Vosshenrich","year":"2024","journal-title":"Semin Roentgenol"},{"key":"R25-20260119","doi-asserted-by":"crossref","first-page":"112317","DOI":"10.1016\/j.forsciint.2024.112317","article-title":"Technical note: an optimized protocol for standard unenhanced whole-body post-mortem Photon Counting CT imaging","volume":"367","author":"Zech","year":"2024","journal-title":"Forensic Sci Int"},{"key":"R27-20260119","doi-asserted-by":"crossref","first-page":"100037","DOI":"10.1016\/j.jposna.2024.100037","article-title":"Updates in pediatric upper extremity imaging","volume":"7","author":"Dittman","year":"2024","journal-title":"J Pediatr Orthop Soc North Am"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001810","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T20:33:38Z","timestamp":1786048418000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001810"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,2]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001810","relation":{},"ISSN":["1532-3145"],"issn-type":[{"value":"1532-3145","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,2]]},"assertion":[{"value":"2025-05-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}