{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T21:59:29Z","timestamp":1780696769443,"version":"3.54.1"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    Preoperative computed tomography (CT)-guided localization is widely used to facilitate the surgical resection of pulmonary nodules (PNs) through video-assisted thoracoscopic surgery (VATS). This meta-analysis aims to compare the clinical performance and safety profile of 2 commonly used localization techniques: the anchored needle (AN) and the hook-wire (HW) method. A systematic search was conducted using the PubMed, Wanfang, and Cochrane Library databases to identify relevant comparative studies. Key outcome measures were extracted and analyzed using Stata v12.0 and RevMan v5.3. Seven retrospective studies conducted in China met the inclusion criteria, encompassing a total of 1557 patients. Among these, 889 patients with 961 PNs underwent CT-guided AN localization, whereas 668 patients with 697 PNs received HW localization. Compared with HW, AN localization demonstrated a significantly higher rate of successful localization (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt;0.001), lower rates of overall complications (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    =0.01), pneumothorax (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    =0.003), and pulmonary hemorrhage (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    =0.004). Patients in the AN group also reported significantly lower pain scores (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt;0.001). Two groups exhibited similar localization (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    =0.48) and VATS (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    =0.93) time. Notable heterogeneity was observed in localization time, complication rate, VATS time, and pain score (\n                    <jats:italic toggle=\"yes\">I<\/jats:italic>\n                    \u00b2=91%, 73%, 94%, and 94%, respectively). No evidence of publication bias was detected across the analyzed outcomes. CT-guided AN localization seems to offer higher successful localization rate and a lower complication rate compared with HW localization for patients undergoing surgical management of PNs.\n                  <\/jats:p>","DOI":"10.1097\/rct.0000000000001823","type":"journal-article","created":{"date-parts":[[2025,11,17]],"date-time":"2025-11-17T18:00:47Z","timestamp":1763402447000},"page":"448-453","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["CT-Guided Anchored Needle Versus Hook-Wire Localization for Pulmonary Nodules: A Meta-Analysis"],"prefix":"10.1097","volume":"50","author":[{"given":"Gang","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Radiology, Xuzhou Central Hospital, Xuzhou"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chong-Jin","family":"Ren","sequence":"additional","affiliation":[{"name":"Department of Thoracic Surgery, Binzhou People\u2019s Hospital, Binzhou"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-Bing","family":"Shi","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xuzhou Central Hospital, Xuzhou"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hua-Mei","family":"Miao","sequence":"additional","affiliation":[{"name":"Department of Radiography, Taizhou Second People\u2019s Hospital Affiliated to Yangzhou University, Taizhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,5]]},"reference":[{"key":"R1-20260605","doi-asserted-by":"crossref","first-page":"3184","DOI":"10.1038\/s41591-024-03211-3","article-title":"Data-driven risk stratification and precision management of pulmonary nodules detected on chest computed tomography","volume":"30","author":"Wang","year":"2024","journal-title":"Nat Med"},{"key":"R2-20260605","doi-asserted-by":"crossref","first-page":"967","DOI":"10.4103\/jcrt.JCRT_449_20","article-title":"Expert consensus workshop report: guidelines for preoperative assisted localization of small pulmonary nodules","volume":"16","author":"Liu","year":"2020","journal-title":"J Cancer Res Ther"},{"key":"R3-20260605","doi-asserted-by":"crossref","first-page":"6705","DOI":"10.21037\/qims-2025-56","article-title":"Preoperative computed tomography-guided localization for pulmonary nodules: a systematic review and meta-analysis of soft hook-wire and coil localization","volume":"15","author":"Meng","year":"2025","journal-title":"Quant Imaging Med Surg"},{"key":"R4-20260605","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1089\/lap.2017.0484","article-title":"Coil localization-guided video-assisted thoracoscopic surgery for lung nodules","volume":"28","author":"Fu","year":"2018","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"R5-20260605","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/s13019-019-0870-6","article-title":"Computed tomography-guided simultaneous coil localization as a bridge to one-stage surgery for multiple lung nodules: a retrospective study","volume":"14","author":"Fu","year":"2019","journal-title":"J Cardiothorac Surg"},{"key":"R6-20260605","doi-asserted-by":"crossref","first-page":"E514","DOI":"10.1111\/ans.15450","article-title":"Computed tomography-guided coil localization for video-assisted thoracoscopic surgery of sub-solid lung nodules: a retrospective study","volume":"89","author":"Teng","year":"2019","journal-title":"ANZ J Surg"},{"key":"R7-20260605","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.chest.2016.09.017","article-title":"Comparative effectiveness and safety of preoperative lung localization for pulmonary nodules: a systematic review and meta-analysis","volume":"151","author":"Park","year":"2017","journal-title":"Chest"},{"key":"R8-20260605","first-page":"1873","article-title":"Preoperative hook-wire localization of nonpalpable breast lesions by use of standard and stereotactic technique","volume":"13","author":"Vuorela","year":"1993","journal-title":"Anticancer Res"},{"key":"R9-20260605","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/j.jtcvs.2019.10.148","article-title":"Multicenter, prospective, observational study of a novel technique for preoperative pulmonary nodule localization","volume":"160","author":"Fan","year":"2020","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R10-20260605","doi-asserted-by":"crossref","first-page":"18950","DOI":"10.1038\/s41598-023-46365-9","article-title":"A novel preoperative image-guided localization for small pulmonary\u2002nodule resection using a claw-suture device","volume":"13","author":"Wang","year":"2023","journal-title":"Sci Rep"},{"key":"R11-20260605","first-page":"470","article-title":"Preoperative computed tomography-guided localization of pulmonary ground\u2011glass nodules: a comparison of conventional and soft hook\u2011wires","volume":"19","author":"Fan","year":"2024","journal-title":"Wideochir Inne Tech Maloinwazyjne"},{"key":"R12-20260605","doi-asserted-by":"crossref","first-page":"313","DOI":"10.3233\/THC-248027","article-title":"Clinical application of two types of Hook-Wire needle localization procedures for pulmonary small nodule biopsy","volume":"32","author":"Lin","year":"2024","journal-title":"Technol Health Care"},{"key":"R13-20260605","first-page":"2975","article-title":"Comparison of lung nodule localization needles and hook-wire for preoperative localization of lung nodules. J Cardiothorac Surg","volume":"47","author":"Tian","year":"2023"},{"key":"R14-20260605","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s13019-024-02497-1","article-title":"Comparison of the safety and effectiveness of the four-hook needle and hook wire for the preoperative positioning of localization ground glass nodules","volume":"19","author":"Wang","year":"2024","journal-title":"J Cardiothorac Surg"},{"key":"R15-20260605","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1186\/s13019-024-03144-5","article-title":"Comparison of different localization needles and postures in localization of pulmonary nodules","volume":"19","author":"Wang","year":"2024","journal-title":"J Cardiothorac Surg"},{"key":"R16-20260605","first-page":"1651","article-title":"Application of two metal-mediated pulmonary nodule localization methods in thoracoscopic precise pneumonectomy","volume":"52","author":"Zhang","year":"2023","journal-title":"Chong Qing Yi Xue"},{"key":"R17-20260605","first-page":"91","article-title":"Preoperative computed tomography-guided localization for pulmonary nodules: comparison between hook-wire and anchored needle localization","volume":"19","author":"Zhou","year":"2024","journal-title":"Wideochir Inne Tech Maloinwazyjne"},{"key":"R18-20260605","doi-asserted-by":"crossref","first-page":"e1000097","DOI":"10.1371\/journal.pmed.1000097","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"6","author":"Moher","year":"2009","journal-title":"PLoS Med"},{"key":"R19-20260605","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1097\/ACM.0000000000000786","article-title":"Appraising the quality of medical education research methods: the Medical Education Research Study Quality Instrument and the Newcastle-Ottawa Scale-Education","volume":"90","author":"Cook","year":"2015","journal-title":"Acad Med"},{"key":"R20-20260605","first-page":"441","article-title":"Comparison between coil and hook-wire localization before video-assisted thoracoscopic surgery for lung nodules: a systematic review and meta-analysis","volume":"17","author":"Wang","year":"2022","journal-title":"Wideochir Inne Tech Maloinwazyjne"},{"key":"R21-20260605","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/s12957-024-03331-7","article-title":"Presurgical computed tomography-guided localization of lung ground glass nodules: comparing hook-wire and indocyanine green","volume":"22","author":"Han","year":"2024","journal-title":"World J Surg Oncol"},{"key":"R22-20260605","doi-asserted-by":"crossref","first-page":"1345288","DOI":"10.3389\/fonc.2024.1345288","article-title":"Comparison of indocyanine green and blue-stained glue for preoperative localization for pulmonary nodules","volume":"14","author":"Lin","year":"2024","journal-title":"Front Oncol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001823","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T21:00:18Z","timestamp":1780693218000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001823"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,17]]},"references-count":22,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001823","relation":{},"ISSN":["1532-3145"],"issn-type":[{"value":"1532-3145","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,17]]},"assertion":[{"value":"2025-08-02","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}