{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T19:07:00Z","timestamp":1783969620362,"version":"3.55.0"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To evaluate the impact of Super-Resolution Deep Learning Reconstruction (SR-DLR) (Canon Medical Systems Corporation) on image quality and myocardial hemodynamic parameters in dynamic myocardial computed tomography (CT) perfusion compared with filtered-back projection (FBP), hybrid iterative reconstruction (IR), and normal-resolution deep learning reconstruction (NR-DLR).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective single-center study included 25 patients (mean age \u00b1 SD, 65 \u00b1 10; 21 men) who underwent dynamic myocardial CT perfusion. For qualitative analysis, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were assessed, while qualitative analysis included overall image quality and lesion visibility. Myocardial blood flow (MBF) at rest and stress, as well as coronary flow reserve (CFR) were analyzed. Image quality and hemodynamic parameters were compared across 4 reconstruction methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      SR-DLR achieved the lowest image noise (20.33 \u00b1 2.45 HU), significantly lower than FBP (145.20 \u00b1 74.81 HU), hybrid IR (47.19 \u00b1 10.02 HU), and NR-DLR (22.92 \u00b1 2.63 HU) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). In rest imaging, SR-DLR showed significantly higher SNR (6.71 \u00b1 1.88) and CNR (15.41 \u00b1 5.48) compared with other reconstruction methods (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Similar improvements were observed in stress imaging, with SR-DLR providing significantly enhanced SNR and CNR compared with all other methods. The mean CFR was 2.75 \u00b1 1.88 for SR-DLR, 2.75 \u00b1 1.99 for NR-DLR, 2.74 \u00b1 2.44 for hybrid IR, and 2.56 \u00b1 3.17 for FBP, with no statistically significant differences observed in any pairwise comparisons. Qualitative analysis showed that SR-DLR achieved the highest overall image quality and lesion visibility, significantly outperforming FBP and comparable to hybrid IR and NR-DLR.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>SR-DLR and NR-DLR significantly enhanced image quality by reducing noise and improving SNR and CNR while maintaining hemodynamic quantification.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001840","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T07:00:10Z","timestamp":1768201210000},"page":"597-605","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["\u201cSuper-Resolution\u201d Deep Learning Image Reconstruction in Dynamic Myocardial Perfusion: A Prospective Evaluation of Image Quality and Hemodynamic Parameters"],"prefix":"10.1097","volume":"50","author":[{"given":"Chuluunbaatar","family":"Otgonbaatar","sequence":"first","affiliation":[{"name":"Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea"},{"name":"Department of Radiology, Mongolian National University of Medical Sciences, Ulaanbaatar, Mongolia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung-Jin","family":"Cha","sequence":"additional","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University of Korea, Wonju, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pil-Hyun","family":"Jeon","sequence":"additional","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University of Korea, Wonju, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaekyun","family":"Ryu","sequence":"additional","affiliation":[{"name":"Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang-Hyun","family":"Jeon","sequence":"additional","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University of Korea, Wonju, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyunjung","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University of Korea, Wonju, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gonchigsuren","family":"Dagvasumberel","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mongolian National University of Medical Sciences, Ulaanbaatar, Mongolia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hackjoon","family":"Shim","sequence":"additional","affiliation":[{"name":"Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea"},{"name":"ConnectAI Research Center, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung Min","family":"Ko","sequence":"additional","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University of Korea, Wonju, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7]]},"reference":[{"key":"R1-20260713","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1161\/CIRCIMAGING.111.969303","article-title":"Computed tomography myocardial perfusion imaging with 320-row detector computed tomography accurately detects myocardial ischemia in patients with obstructive coronary artery disease","volume":"5","author":"George","year":"2012","journal-title":"Circ Cardiovasc Imaging"},{"key":"R2-20260713","doi-asserted-by":"crossref","first-page":"1120","DOI":"10.1093\/eurheartj\/eht488","article-title":"Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study","volume":"35","author":"Rochitte","year":"2014","journal-title":"Eur Heart J"},{"key":"R3-20260713","first-page":"413","article-title":"The emerging role of cardiac computed tomography for the assessment of coronary perfusion: a systematic review and meta-analysis","volume":"28","author":"Tashakkor","year":"2012","journal-title":"Can J Cardiol"},{"key":"R4-20260713","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.jacc.2006.04.014","article-title":"Multidetector computed tomography myocardial perfusion imaging during adenosine stress","volume":"48","author":"George","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"R5-20260713","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1148\/radiol.14140806","article-title":"Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease: a head-to-head comparison from the CORE320 multicenter diagnostic performance study","volume":"272","author":"George","year":"2014","journal-title":"Radiology"},{"key":"R6-20260713","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1007\/s00330-013-3063-z","article-title":"Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV\/370-mAs and 100-kV\/300-mAs protocols","volume":"24","author":"Fujita","year":"2014","journal-title":"Eur Radiol"},{"key":"R7-20260713","doi-asserted-by":"crossref","first-page":"58","DOI":"10.3348\/kjr.2019.0323","article-title":"Myocardial coverage and radiation dose in dynamic myocardial perfusion imaging using third-generation dual-source CT","volume":"21","author":"Takafuji","year":"2020","journal-title":"Korean J Radiol"},{"key":"R8-20260713","doi-asserted-by":"crossref","first-page":"599","DOI":"10.2214\/AJR.23.29506","article-title":"Coronary stent evaluation by CTA: image quality comparison between super-resolution deep learning reconstruction and other reconstruction algorithms","volume":"221","author":"Nagayama","year":"2023","journal-title":"AJR Am J Roentgenol"},{"key":"R9-20260713","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/s44348-024-00031-4","article-title":"Super-resolution deep learning image reconstruction: image quality and myocardial homogeneity in coronary computed tomography angiography","volume":"32","author":"Otgonbaatar","year":"2024","journal-title":"J Cardiovasc Imaging"},{"key":"R10-20260713","doi-asserted-by":"crossref","first-page":"2647","DOI":"10.1007\/s00330-023-10110-7","article-title":"Coronary computed tomography angiographic detection of in-stent restenosis via deep learning reconstruction: a feasibility study","volume":"34","author":"Kawai","year":"2024","journal-title":"Eur Radiol"},{"key":"R11-20260713","doi-asserted-by":"crossref","first-page":"2393","DOI":"10.1177\/02841851231174463","article-title":"Coronary artery calcium quantification: comparison between filtered-back projection, hybrid iterative reconstruction, and deep learning reconstruction techniques","volume":"64","author":"Otgonbaatar","year":"2023","journal-title":"Acta radiol"},{"key":"R12-20260713","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1177\/02841851221118476","article-title":"Deep learning reconstruction allows for usage of contrast agent of lower concentration for coronary CTA than filtered back projection and hybrid iterative reconstruction","volume":"64","author":"Otgonbaatar","year":"2023","journal-title":"Acta radiol"},{"key":"R13-20260713","doi-asserted-by":"crossref","first-page":"4674","DOI":"10.1007\/s00330-025-11399-2","article-title":"Ultra-low-dose coronary CT angiography via super-resolution deep learning reconstruction: impact on image quality, coronary plaque, and stenosis analysis","volume":"35","author":"Zou","year":"2025","journal-title":"Eur Radiol"},{"key":"R14-20260713","doi-asserted-by":"crossref","first-page":"e121","DOI":"10.1016\/j.nuclcard.2006.08.009","article-title":"Positron emission tomography myocardial perfusion and glucose metabolism imaging","volume":"13","author":"Machac","year":"2006","journal-title":"J Nucl Cardiol"},{"key":"R15-20260713","first-page":"1908","article-title":"Improvement of algorithm for quantification of regional myocardial blood flow using 15O-water with PET","volume":"45","author":"Katoh","year":"2004","journal-title":"J Nucl Med"},{"key":"R16-20260713","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1007\/s12350-010-9256-9","article-title":"Quantification of myocardial blood flow and flow reserve: technical aspects","volume":"17","author":"Klein","year":"2010","journal-title":"J Nucl Cardiol"},{"key":"R17-20260713","doi-asserted-by":"crossref","first-page":"e11354","DOI":"10.1097\/MD.0000000000011354","article-title":"Diagnostic value of quantitative coronary flow reserve and myocardial blood flow estimated by dynamic 320 MDCT scanning in patients with obstructive coronary artery disease","volume":"97","author":"Obara","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"R18-20260713","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1007\/s00330-014-3164-3","article-title":"Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET","volume":"24","author":"Kikuchi","year":"2014","journal-title":"Eur Radiol"},{"key":"R19-20260713","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40658-025-00729-4","article-title":"13)N-NH(3) myocardial perfusion imaging with reduced scan duration: a feasibility study in the era of total-body PET\/CT","volume":"12","author":"Zhang","year":"2025","journal-title":"EJNMMI Phys"},{"key":"R20-20260713","doi-asserted-by":"crossref","first-page":"e222827","DOI":"10.1148\/radiol.222827","article-title":"Evolving developments in cardiac CT","volume":"307","author":"Dodd","year":"2023","journal-title":"Radiology"},{"key":"R21-20260713","doi-asserted-by":"crossref","first-page":"e233234","DOI":"10.1148\/radiol.233234","article-title":"CT myocardial perfusion and CT-FFR versus invasive FFR for hemodynamic relevance of coronary artery disease","volume":"312","author":"Soschynski","year":"2024","journal-title":"Radiology"},{"key":"R22-20260713","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.1007\/s00330-018-5709-3","article-title":"Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms","volume":"29","author":"Skornitzke","year":"2019","journal-title":"Eur Radiol"},{"key":"R23-20260713","doi-asserted-by":"crossref","first-page":"1781","DOI":"10.1007\/s10554-020-01878-6","article-title":"Clinical application of four-dimensional noise reduction filtering with a similarity algorithm in dynamic myocardial computed tomography perfusion imaging","volume":"36","author":"Kouchi","year":"2020","journal-title":"Int J Cardiovasc Imaging"},{"key":"R24-20260713","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1177\/02841851221108804","article-title":"Multireader image quality evaluation of dynamic myocardial computed tomography perfusion imaging with a novel four-dimensional noise reduction filter","volume":"64","author":"Sliwicka","year":"2023","journal-title":"Acta radiol"},{"key":"R25-20260713","doi-asserted-by":"crossref","first-page":"2215","DOI":"10.1161\/CIRCULATIONAHA.111.050427","article-title":"Improved cardiac risk assessment with noninvasive measures of coronary flow reserve","volume":"124","author":"Murthy","year":"2011","journal-title":"Circulation"},{"key":"R26-20260713","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1161\/CIRCULATIONAHA.109.915009","article-title":"Cardiac positron emission tomography\/computed tomography imaging accurately detects anatomically and functionally significant coronary artery disease","volume":"122","author":"Kajander","year":"2010","journal-title":"Circulation"},{"key":"R27-20260713","doi-asserted-by":"crossref","first-page":"2325","DOI":"10.1161\/CIRCULATIONAHA.117.029992","article-title":"Integrated noninvasive physiological assessment of coronary circulatory function and impact on cardiovascular mortality in patients with stable coronary artery disease","volume":"136","author":"Gupta","year":"2017","journal-title":"Circulation"},{"key":"R28-20260713","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.jcct.2016.01.008","article-title":"Underestimation of myocardial blood flow by dynamic perfusion CT: Explanations by two-compartment model analysis and limited temporal sampling of dynamic CT","volume":"10","author":"Ishida","year":"2016","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R29-20260713","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1016\/j.jcmg.2016.09.028","article-title":"Integrating CT myocardial perfusion and CT-FFR in the work-up of coronary artery disease","volume":"10","author":"Coenen","year":"2017","journal-title":"JACC Cardiovasc Imaging"},{"key":"R30-20260713","doi-asserted-by":"crossref","first-page":"2460","DOI":"10.1016\/j.jcmg.2019.02.015","article-title":"Dynamic stress computed tomography perfusion with a whole-heart coverage scanner in addition to coronary computed tomography angiography and fractional flow reserve computed tomography derived","volume":"12","author":"Pontone","year":"2019","journal-title":"JACC Cardiovasc Imaging"},{"key":"R31-20260713","first-page":"1768","article-title":"Frequency and clinical significance of myocardial ischemia detected early after coronary stent implantation","volume":"42","author":"Rod\u00e9s-Cabau","year":"2001","journal-title":"J Nucl Med"},{"key":"R32-20260713","doi-asserted-by":"crossref","first-page":"100570","DOI":"10.1016\/j.ejro.2024.100570","article-title":"Super resolution deep learning reconstruction for coronary CT angiography: A structured phantom study","volume":"12","author":"Higaki","year":"2024","journal-title":"Eur J Radiol Open"},{"key":"R33-20260713","doi-asserted-by":"crossref","first-page":"e230085","DOI":"10.1148\/ryct.230085","article-title":"Super-resolution deep learning reconstruction for improved image quality of coronary CT angiography","volume":"5","author":"Takafuji","year":"2023","journal-title":"Radiol Cardiothorac Imaging"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001840","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T19:00:50Z","timestamp":1783969250000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001840"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,12]]},"references-count":33,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001840","relation":{},"ISSN":["1532-3145"],"issn-type":[{"value":"1532-3145","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,12]]},"assertion":[{"value":"2025-07-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}