{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T21:06:48Z","timestamp":1789420008821,"version":"build-2803163510"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T00:00:00Z","timestamp":1776211200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>This study assessed whether the weight-based, variable tube voltage (Bayer MEDRAD Centargo SMART) protocol compared with a fixed contrast, fixed tube voltage (referred to as the \u2018OLD\u2019) protocol for cancer patients undergoing CT chest, abdomen, and pelvis (CAP) scans could reduce contrast dose, without a reduction in contrast enhancement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A total of 149 oncology patients, each underwent 2 surveillance CT CAP scans using both the OLD and SMART protocols, typically with a 3-month interval between scans. Contrast volume was recorded for each protocol as well as the CT attenuation measurement Hounsfield unit (HU) at the ascending aorta, pulmonary trunk, right atrial appendage, middle hepatic vein, main portal vein, and renal cortex, as well as dose-length product (DLP, mGy\/cm) and CT Dose Index volume (CTDIvol, mGy).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The SMART protocol used less contrast per patient with a median volume of 80 versus 100\u00a0mL representing a 20% absolute reduction. Quantitative contrast enhancement measurements demonstrated non-inferior HU values in the SMART protocol at all sites. This was achieved with a 19% DLP and 9% CTDIvol decrease in radiation exposure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The weight-based contrast, variable tube voltage protocol effectively reduces contrast volume without increasing radiation dose and does not reduce contrast enhancement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001865","type":"journal-article","created":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T17:00:10Z","timestamp":1776272410000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison Between Weight-Based Variable-Voltage and Fixed Volume-Voltage Protocols in Cancer Surveillance Computed Tomography"],"prefix":"10.1097","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9364-7545","authenticated-orcid":false,"given":"Joseph J.","family":"Ipsen","sequence":"first","affiliation":[{"name":"Department of Medical Imaging, Fiona Stanley Fremantle Hospitals Group, Murdoch"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kirsten","family":"Richards","sequence":"additional","affiliation":[{"name":"Data Analyst Digital Health Transformation Directorate, South Metropolitan Health Service"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James H.","family":"Seow","sequence":"additional","affiliation":[{"name":"Department of Radiology, Royal Perth Hospital, Perth"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Diamant","sequence":"additional","affiliation":[{"name":"Department of Medicine, Western Australian Country Health Service, Bunbury, WA, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alvin","family":"Tanaya","sequence":"additional","affiliation":[{"name":"Department of Surgery, Fiona Stanley Hospital, Murdoch"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arathy","family":"Harikumar","sequence":"additional","affiliation":[{"name":"Data Analyst Digital Health Transformation Directorate, South Metropolitan Health Service"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Williams","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, Fiona Stanley Fremantle Hospitals Group, Murdoch"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angela","family":"Kilcoyne","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, Fiona Stanley Fremantle Hospitals Group, Murdoch"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashik","family":"Amlani","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, Fiona Stanley Fremantle Hospitals Group, Murdoch"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Welman","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, Fiona Stanley Fremantle Hospitals Group, Murdoch"},{"name":"Department of Radiology, Royal Perth Hospital, Perth"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9]]},"reference":[{"key":"R1-20260914","first-page":"6972","article-title":"Diagnostic protocols in oncology: workup and treatment planning. Part 1: the optimitation of CT protocol","volume":"25","author":"Granata","year":"2021","journal-title":"Eur Rev Medical & Pharmacol Sci"},{"key":"R2-20260914","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1259\/bjr\/34082277","article-title":"Value of contrast-enhanced multiphase CT in combined PET\/CT protocols for oncological imaging","volume":"80","author":"Pfannenberg","year":"2014","journal-title":"Br J Radiol"},{"key":"R3-20260914","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1148\/radiol.2019192094","article-title":"Use of intravenous iodinated contrast media in patients with kidney disease: consensus statements from the American College of Radiology and the National Kidney Foundation","volume":"294","author":"Davenport","year":"2020","journal-title":"Radiology"},{"key":"R4-20260914","first-page":"e14842","article-title":"Contrast-induced nephropathy: a review of mechanisms and risks","volume":"13","author":"Shams","year":"2021","journal-title":"Cureus"},{"key":"R5-20260914","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1007\/s00330-013-2996-6","article-title":"Incidence of contrast-induced nephropathy in hospitalised patients with cancer","volume":"24","author":"Cicin","year":"2014","journal-title":"Eur Radiol"},{"key":"R6-20260914","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1016\/j.amjmed.2015.02.018","article-title":"Intravenous imaging contrast media complications: the basics that every clinician needs to know","volume":"128","author":"Rose","year":"2015","journal-title":"Am J Med"},{"key":"R7-20260914","first-page":"222","article-title":"Contemporary use of and outcomes associated with ultra-low contrast volume in patients undergoing percutaneous coronary interventions","volume":"93","author":"Gurm","year":"2019","journal-title":"Catheter Cardiovasc Interv"},{"key":"R8-20260914","first-page":"51","article-title":"Contrast-induced nephropathy; a literature review","volume":"3","author":"Golshahi","year":"2014","journal-title":"J Nephropathol"},{"key":"R9-20260914","doi-asserted-by":"crossref","first-page":"944","DOI":"10.3174\/ajnr.A7544","article-title":"Navigating supply chain disruptions of iodinated contrast agent for neuroimaging and how business intelligence can help the decision process","volume":"43","author":"Bammer","year":"2022","journal-title":"AJNR Am J Neuroradiol"},{"key":"R10-20260914","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/s13244-022-01175-x","article-title":"Tackling the increasing contamination of the water supply by iodinated contrast media","volume":"13","author":"Dekker","year":"2022","journal-title":"Insights Imaging"},{"key":"R11-20260914","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.radi.2017.08.011","article-title":"Weight-adapted iodinated contrast media administration in abdomino-pelvic CT: can image quality be maintained?","volume":"24","author":"Perrin","year":"2018","journal-title":"Radiography"},{"key":"R12-20260914","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jacr.2016.09.001","article-title":"Effect of fixed-volume and weight-based dosing regimens on the cost and volume of administered iodinated contrast material at abdominal CT","volume":"14","author":"Davenport","year":"2017","journal-title":"J Am College Radiol"},{"key":"R13-20260914","first-page":"10","article-title":"Customised weight-based volume contrast media protocol for multiphase abdominal computed tomography","volume":"49","author":"Yap","year":"2024","journal-title":"Singapore Med J"},{"key":"R14-20260914","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1148\/radiol.2452061749","article-title":"Pancreas: patient body weight\u2013tailored contrast material injection protocol versus fixed dose protocol at dynamic CT","volume":"245","author":"Yanaga","year":"2007","journal-title":"Radiology"},{"key":"R15-20260914","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.jmir.2021.01.003","article-title":"Customised weight-based volume contrast media protocol in CT of chest, abdomen and pelvis examination","volume":"52","author":"Yap","year":"2021","journal-title":"J Med Imaging Rad Sci"},{"key":"R16-20260914","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13244-021-00980-0","article-title":"Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols","volume":"12","author":"Caruso","year":"2021","journal-title":"Insights Imaging"},{"key":"R17-20260914","doi-asserted-by":"crossref","first-page":"147","DOI":"10.2214\/AJR.12.9295","article-title":"Individualization of abdominopelvic CT protocols with lower tube voltage to reduce i.v. contrast dose or radiation dose","volume":"201","author":"Hough","year":"2013","journal-title":"AJR Am J Roentgenol"},{"key":"R18-20260914","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1148\/rg.351130010","article-title":"The right atrium: gateway to the heart\u2014anatomic and pathologic imaging findings","volume":"35","author":"Malik","year":"2015","journal-title":"Radiographics"},{"key":"R19-20260914","doi-asserted-by":"crossref","first-page":"1314. e1","DOI":"10.1016\/j.crad.2016.07.009","article-title":"Comparison between a fixed-dose contrast protocol and a weight-based contrast dosing protocol in abdominal CT","volume":"71","author":"George","year":"2016","journal-title":"Clin Radiol"},{"key":"R21-20260914","doi-asserted-by":"crossref","first-page":"11320","DOI":"10.1038\/s41598-021-90750-1","article-title":"Trends in the prevalence of adult overweight and obesity in Australia, and its association with geographic remoteness","volume":"11","author":"Keramat","year":"2021","journal-title":"Sci Rep"},{"key":"R22-20260914","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.rcl.2007.03.001","article-title":"Impact of obesity on radiology","volume":"45","author":"Uppot","year":"2007","journal-title":"Radiol Clin North Am"},{"key":"R23-20260914","doi-asserted-by":"crossref","first-page":"S88","DOI":"10.1016\/S0720-048X(02)00365-0","article-title":"Use of high concentration contrast media: principles and rationale\u2014vascular district","volume":"45","author":"Fleischmann","year":"2003","journal-title":"Eur J Radiol"},{"key":"R24-20260914","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1148\/radiology.216.3.r00se26718","article-title":"Abdominal helical CT: evaluation of optimal doses of intravenous contrast material\u2014a prospective randomized study","volume":"216","author":"Yamashita","year":"2000","journal-title":"Radiology"},{"key":"R25-20260914","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/RCT.0000000000001677","article-title":"Development and clinical evaluation of a contrast optimizer for contrast-enhanced CT imaging of the liver","volume":"49","author":"Setiawan","year":"2022","journal-title":"J Comput Assist Tomogr"},{"key":"R26-20260914","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1111\/1754-9485.13363","article-title":"Streak artefacts in Computed Tomography Urography: Comparative evaluation between two different iodinated contrast media","volume":"66","author":"Pedote","year":"2022","journal-title":"J Med Imaging Radiat Oncol"},{"key":"R27-20260914","doi-asserted-by":"crossref","first-page":"8491","DOI":"10.3390\/ijms22168491","article-title":"Cancer cachexia: its mechanism and clinical significance","volume":"22","author":"Nishikawa","year":"2021","journal-title":"Int J Mol Sci"},{"key":"R28-20260914","doi-asserted-by":"crossref","first-page":"3729","DOI":"10.1007\/s00330-024-11329-8","article-title":"Are we systematically overdosing women? Revisiting standardized contrast protocols for thoracoabdominal CT scans","volume":"35","author":"Becker","year":"2025","journal-title":"Eur Radiol"},{"key":"R29-20260914","doi-asserted-by":"crossref","first-page":"1915","DOI":"10.1007\/s00330-024-11017-7","article-title":"Survey of CT radiation doses and iodinated contrast medium administration: an international multicentric study","volume":"35","author":"Karout","year":"2024","journal-title":"Eur Radiol"},{"key":"R30-20260914","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1148\/radiology.197.1.7568859","article-title":"Hepatic spiral CT: reduction of dose of intravenous contrast material","volume":"197","author":"Brink","year":"1995","journal-title":"Radiology"},{"key":"R31-20260914","doi-asserted-by":"crossref","first-page":"2670","DOI":"10.1007\/s00330-006-0386-z","article-title":"Understanding multislice CT urography techniques: many roads lead to Rome","volume":"16","author":"Nolte-Ernsting","year":"2006","journal-title":"Eur Radiol"},{"key":"R32-20260914","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s41747-018-0074-1","article-title":"Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight","volume":"2","author":"Zanardo","year":"2018","journal-title":"Eur Radiol Exp"},{"key":"R33-20260914","doi-asserted-by":"crossref","first-page":"2573","DOI":"10.3390\/cancers15092573","article-title":"Artificial intelligence in CT and MR imaging for oncological applications","volume":"15","author":"Paudyal","year":"2023","journal-title":"Cancers"},{"key":"R34-20260914","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1111\/1754-9485.13538","article-title":"The great contrast shortage of 2022\u2014lessons learnt in Australia","volume":"67","author":"Kisby","year":"2023","journal-title":"J Med Imaging Radiat Oncol"},{"key":"R35-20260914","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.jacr.2010.08.031","article-title":"Contrast and cost savings by implementation of a multidose bulk IV contrast delivery system","volume":"8","author":"Routhier","year":"2011","journal-title":"J Am College Radiol"},{"key":"R36-20260914","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.radi.2024.06.023","article-title":"More sustainable use of iodinated contrast media\u2014why?","volume":"30","author":"England","year":"2024","journal-title":"Radiography"},{"key":"R37-20260914","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1016\/j.acra.2022.12.029","article-title":"Modeling the environmental and financial impact of multi-dose vs. single-dose iodinated contrast media packaging and delivery systems","volume":"30","author":"Lindsey","year":"2023","journal-title":"Acad Radiol"},{"key":"R38-20260914","first-page":"79","article-title":"Performance of centargo: a novel piston-based injection system for high throughput in CE CT","volume":"15","author":"Kemper","year":"2022","journal-title":"Med Devices (Auckl)"},{"key":"R39-20260914","doi-asserted-by":"crossref","first-page":"14580","DOI":"10.1038\/s41598-022-18741-4","article-title":"X-ray attenuation of bone, soft and adipose tissue in CT from 70 to 140 kV and comparison with 3D printable additive manufacturing materials","volume":"12","author":"Ma","year":"2022","journal-title":"Sci Rep"},{"key":"R40-20260914","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1120\/jacmp.v14i6.4417","article-title":"Scanner and kVp dependence of measured CT numbers in the ACR CT phantom","volume":"14","author":"Cropp","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"R41-20260914","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1002\/pro6.1177","article-title":"The influence of different kVs and phantoms on computed tomography number to relative electron density calibration curve for radiotherapy dose calculation","volume":"6","author":"Jaafar","year":"2022","journal-title":"Precis Rad Oncol"},{"key":"R42-20260914","doi-asserted-by":"crossref","first-page":"285","DOI":"10.3348\/jksr.2016.75.4.285","article-title":"100 kVp low-tube voltage abdominal CT in adults: radiation dose reduction and image quality comparison of 120 kVp abdominal CT","volume":"75","author":"Ha","year":"2016","journal-title":"J Korean Soc Radiol"},{"key":"R43-20260914","doi-asserted-by":"crossref","first-page":"714","DOI":"10.3348\/kjr.2011.12.6.714","article-title":"A comparison of the use of contrast media with different iodine concentrations for multidetector CT of the kidney","volume":"12","author":"Jung","year":"2011","journal-title":"Korean J Radiol"},{"key":"R44-20260914","doi-asserted-by":"crossref","first-page":"e70071","DOI":"10.1002\/pds.70071","article-title":"Core Concepts: self-controlled designs in pharmacoepidemiology","volume":"34","author":"Bots","year":"2025","journal-title":"Pharmacoepidemiol Drug Saf"},{"key":"R45-20260914","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1148\/radiol.2019182223","article-title":"CT angiography of the aorta: contrast timing by using a fixed versus a patient-specific trigger delay","volume":"291","author":"Hinzpeter","year":"2019","journal-title":"Radiology"},{"key":"R46-20260914","first-page":"e4617","article-title":"Automatic bolus tracking versus fixed time-delay technique in biphasic multidetector computed tomography of the abdomen","volume":"11","author":"Adibi","year":"2014","journal-title":"Iran J Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001865","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T21:00:14Z","timestamp":1789419614000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001865"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,15]]},"references-count":45,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001865","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2026,4,15]]},"assertion":[{"value":"2025-12-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}