{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T21:07:18Z","timestamp":1789420038870,"version":"build-2803163510"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To identify the noise-matched hybrid-iterative reconstruction (IR) blending level for 1024-matrix images with noise equivalent to that of 512-matrix images while preserving comparable image quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In the phantom study, we identified the noise-matched hybrid-IR blending level for 1024-matrix images that achieved a noise level equivalent to 512-matrix images reconstructed with adaptive statistical iterative reconstruction-Veo (ASiR-V) 30%. This retrospective study included 63 patients (40 women; median age: 74y) who had undergone single-energy pancreatic protocol computed tomography (CT) from August 2023 to June 2024. For each patient, 3 image sets at the pancreatic phase were reconstructed: 512-matrix with ASiR-V 30% (group 1), 1024-matrix with ASiR-V 30% (group 2), and 1024-matrix with the noise-matched ASiR-V blending level (group 3). Background noise was measured as the SD of CT attenuation in the abdominal subcutaneous fat. Edge-rise slope (ERS) at the pancreas-fat interface was used to quantify edge sharpness. Two radiologists assessed overall image quality using a 5-point scale.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The phantom study identified 60% as the noise-matched blending level for group 3. Background noise was significantly lower in the order of groups 3, 1, and 2, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). ERS value was significantly higher in the order of groups 2, 3, and 1, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Overall image quality was significantly superior in the order of groups 3, 1, and 2, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001 for both radiologists).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Increasing the matrix size leads to greater image noise with conventional reconstruction; however, applying a noise-matched hybrid-IR blending level allowed 1024-matrix images to maintain image quality while improving edge sharpness.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rct.0000000000001878","type":"journal-article","created":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T15:02:20Z","timestamp":1778511740000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Noise-Matched Blending Level Selection for 1024-Matrix CT Images Using Hybrid-Iterative Reconstruction: Comparison With 512-Matrix Images"],"prefix":"10.1097","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-8883-9434","authenticated-orcid":false,"given":"Shingo","family":"Omata","sequence":"first","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3611-4790","authenticated-orcid":false,"given":"Yoshifumi","family":"Noda","sequence":"additional","affiliation":[{"name":"Department of Radiology"},{"name":"Frontier Science for Imaging, Gifu University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukako","family":"Iritani","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoto","family":"Ozawa","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyuki","family":"Kawai","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuro","family":"Kaga","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukiko","family":"Takai","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akio","family":"Ito","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masashi","family":"Asano","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Iwata","sequence":"additional","affiliation":[{"name":"Department of Radiology Services, Gifu University Hospital, Gifu, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiharu","family":"Miyoshi","sequence":"additional","affiliation":[{"name":"Department of Radiology Services, Gifu University Hospital, Gifu, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdelazim E.","family":"Elhelaly","sequence":"additional","affiliation":[{"name":"Department of Radiology"},{"name":"Frontier Science for Imaging, Gifu University"},{"name":"Department of Food Hygiene and Control, Faculty of Veterinary Medicine, Suez Canal University, Ismailia, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirohiko","family":"Imai","sequence":"additional","affiliation":[{"name":"Department of Radiology"},{"name":"Innovation Research Center for Quantum Medicine, Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroki","family":"Kato","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masayuki","family":"Matsuo","sequence":"additional","affiliation":[{"name":"Department of Radiology"},{"name":"Frontier Science for Imaging, Gifu University"},{"name":"Innovation Research Center for Quantum Medicine, Graduate School of Medicine"},{"name":"Center for One Medicine Innovative Translational Research (COMIT), Institute for Advanced Study, Gifu University, Gifu, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9]]},"reference":[{"key":"R1-20260914","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/RLI.0000000000000524","article-title":"High-resolution chest computed tomography imaging of the lungs: impact of 1024 matrix reconstruction and photon-counting detector computed tomography","volume":"54","author":"Bartlett","year":"2019","journal-title":"Invest Radiol"},{"key":"R2-20260914","doi-asserted-by":"crossref","first-page":"e241479","DOI":"10.1148\/radiol.241479","article-title":"Coronary plaque quantification with ultrahigh-spatial-resolution photon-counting detector CT: intraindividual comparison with energy-integrating detector CT","volume":"314","author":"Vecsey-Nagy","year":"2025","journal-title":"Radiology"},{"key":"R3-20260914","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1097\/RCT.0000000000001464","article-title":"High spatial-resolution skull base imaging with photon-counting computed tomography and energy-integrating computed tomography: a comparative phantom study","volume":"47","author":"Rajagopal","year":"2023","journal-title":"J Comput Assist Tomogr"},{"key":"R4-20260914","doi-asserted-by":"crossref","first-page":"4383","DOI":"10.1007\/s00261-024-04414-5","article-title":"Photon-counting CT: technical features and clinical impact on abdominal imaging","volume":"49","author":"Onishi","year":"2024","journal-title":"Abdom Radiol (NY)"},{"key":"R5-20260914","doi-asserted-by":"crossref","first-page":"e0234644","DOI":"10.1371\/journal.pone.0234644","article-title":"1024-pixel image matrix for chest CT\u2014impact on image quality of bronchial structures in phantoms and patients","volume":"15","author":"Euler","year":"2020","journal-title":"PLoS One"},{"key":"R6-20260914","doi-asserted-by":"crossref","first-page":"111953","DOI":"10.1016\/j.ejrad.2025.111953","article-title":"Super-resolution deep-learning reconstruction with 1024 matrix improves CT image quality for pancreatic ductal adenocarcinoma assessment","volume":"184","author":"Nagayama","year":"2025","journal-title":"Eur J Radiol"},{"key":"R8-20260914","doi-asserted-by":"crossref","first-page":"191","DOI":"10.2214\/AJR.09.2953","article-title":"Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm","volume":"194","author":"Silva","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"R9-20260914","doi-asserted-by":"crossref","first-page":"20150463","DOI":"10.1259\/bjr.20150463","article-title":"The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique","volume":"88","author":"Kwon","year":"2015","journal-title":"Br J Radiol"},{"key":"R10-20260914","doi-asserted-by":"crossref","first-page":"1668","DOI":"10.2214\/AJR.20.23397","article-title":"Protocol optimization considerations for implementing deep learning CT reconstruction","volume":"216","author":"Szczykutowicz","year":"2021","journal-title":"AJR Am J Roentgenol"},{"key":"R11-20260914","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1007\/s00330-021-08121-3","article-title":"Deep learning image reconstruction algorithm for pancreatic protocol dual-energy computed tomography: image quality and quantification of iodine concentration","volume":"32","author":"Noda","year":"2022","journal-title":"Eur Radiol"},{"key":"R13-20260914","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.jcct.2024.09.014","article-title":"Energy-integrating detector based ultra-high-resolution CT with deep learning reconstruction for the assessment of calcified lesions in coronary artery disease","volume":"18","author":"Sone","year":"2024","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R14-20260914","doi-asserted-by":"crossref","DOI":"10.1007\/s00261-025-05372-2","article-title":"Improved visualization of pancreas and tumor boundaries using high-frequency kernels with deep-learning image reconstruction at high-strength level","author":"Kawai","year":"2026","journal-title":"Abdom Radiol (NY)"},{"key":"R15-20260914","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1007\/s11604-023-01448-5","article-title":"Comparison of image quality, arterial depiction, and radiation dose between two rapid kVp-switching dual-energy CT scanners in CT angiography at 40-keV","volume":"41","author":"Kaga","year":"2023","journal-title":"Jpn J Radiol"},{"key":"R16-20260914","doi-asserted-by":"crossref","first-page":"e554","DOI":"10.1016\/j.crad.2023.12.024","article-title":"Effect of X-ray tube on image quality and pancreatic ductal adenocarcinoma conspicuity in pancreatic protocol dual-energy CT","volume":"79","author":"Noda","year":"2024","journal-title":"Clin Radiol"},{"key":"R17-20260914","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1016\/j.acra.2017.11.017","article-title":"Effect of matrix size on the image quality of ultra-high-resolution CT of the lung: comparison of 512\u00a0\u00d7\u00a0512, 1024\u00a0\u00d7\u00a01024, and 2048\u00a0\u00d7\u00a02048","volume":"25","author":"Hata","year":"2018","journal-title":"Acad Radiol"},{"key":"R18-20260914","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1016\/j.radi.2023.05.005","article-title":"Optimization of chest CT protocols based on pixel image matrix, kernels and iterative reconstruction levels\u2014a phantom study","volume":"29","author":"Sandbukt Johnsen","year":"2023","journal-title":"Radiography (Lond)"},{"key":"R19-20260914","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1093\/bjr\/tqae170","article-title":"Assessment of interstitial lung disease in a systemic sclerosis patient cohort using photon-counting detector CT with ultra-high resolution and a 1024-pixel image matrix","volume":"97","author":"Jungblut","year":"2024","journal-title":"Br J Radiol"},{"key":"R20-20260914","doi-asserted-by":"crossref","first-page":"100553","DOI":"10.1016\/j.ejro.2024.100553","article-title":"Imaging of pancreatic ductal adenocarcinoma\u2014an update for all stages of patient management","volume":"12","author":"Bilreiro","year":"2024","journal-title":"Eur J Radiol Open"},{"key":"R21-20260914","doi-asserted-by":"crossref","first-page":"111736","DOI":"10.1016\/j.ejrad.2024.111736","article-title":"Imaging the pancreas with photon-counting CT\u2014a review of normal pancreatic anatomy","volume":"181","author":"Brandt","year":"2024","journal-title":"Eur J Radiol"},{"key":"R22-20260914","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.2214\/AJR.21.26014","article-title":"CT abnormalities of the pancreas associated with the subsequent diagnosis of clinical stage I pancreatic ductal adenocarcinoma more than 1 year later: a case-control study","volume":"217","author":"Toshima","year":"2021","journal-title":"AJR Am J Roentgenol"},{"key":"R23-20260914","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1002\/acm2.12476","article-title":"An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: impact of field of view on spatial resolution of CT images","volume":"19","author":"Anam","year":"2018","journal-title":"J Appl Clin Med Phys"},{"key":"R24-20260914","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1007\/s11604-025-01755-z","article-title":"Phantom-based evaluation of image quality in Transformer-enhanced 2048-matrix CT imaging at low and ultralow doses","volume":"43","author":"Li","year":"2025","journal-title":"Jpn J Radiol"},{"key":"R25-20260914","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1007\/s00330-019-06359-6","article-title":"CT iterative reconstruction algorithms: a task-based image quality assessment","volume":"30","author":"Greffier","year":"2020","journal-title":"Eur Radiol"},{"key":"R26-20260914","doi-asserted-by":"crossref","first-page":"4115","DOI":"10.1118\/1.4725171","article-title":"Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms","volume":"39","author":"Richard","year":"2012","journal-title":"Med Phys"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001878","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T21:00:29Z","timestamp":1789419629000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001878"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,11]]},"references-count":24,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001878","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5,11]]},"assertion":[{"value":"2026-02-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}