{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T21:07:27Z","timestamp":1789420047989,"version":"build-2803163510"},"reference-count":70,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Magnetic resonance imaging (MRI) is well established as a cornerstone of musculoskeletal imaging. Although most clinical musculoskeletal MRI examinations are performed at 1.5\u00a0T and 3\u00a0T, recent advancements in low-field MRI have enabled imaging at 0.55\u00a0T with diagnostic utility approaching that of higher field strengths. Advances in transmit-receive chain design enhance signal efficiency, and deep learning-based image reconstruction algorithms substantially improve apparent signal-to-noise ratios. Low-field MRI also offers potential advantages, including reduced system and installation costs, decreased susceptibility to metal artifacts, and improved patient comfort. However, limitations remain, most notably the difficulty in achieving robust fat suppression and the inherently lower signal-to-noise ratio. This review discusses the technical principles, image quality considerations, economic factors, and clinical challenges associated with low-field MRI, with a particular focus on applications in the musculoskeletal system.<\/jats:p>","DOI":"10.1097\/rct.0000000000001879","type":"journal-article","created":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T12:00:29Z","timestamp":1778500829000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Low-Field Musculoskeletal MRI: Recent Advances, Challenges, and Practice Considerations"],"prefix":"10.1097","volume":"50","author":[{"given":"Paul R.","family":"Wojack","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3067-2345","authenticated-orcid":false,"given":"Iman","family":"Khodarahmi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9]]},"reference":[{"key":"R1-20260914","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/RLI.0000000000000824","article-title":"The clinical utility of magnetic resonance imaging according to field strength, specifically addressing the breadth of current state-of-the-art systems, which include 0.55 T, 1.5 T, 3 T, and 7 T","volume":"57","author":"Runge","year":"2022","journal-title":"Invest Radiol"},{"key":"R2-20260914","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1097\/RLI.0000000000000783","article-title":"Scientific advances, investigative radiology 2020 (and beyond)","volume":"56","author":"Runge","year":"2021","journal-title":"Invest Radiol"},{"key":"R3-20260914","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1097\/RLI.0000000000000801","article-title":"The value of 3 Tesla field strength for musculoskeletal magnetic resonance imaging","volume":"56","author":"Khodarahmi","year":"2021","journal-title":"Invest Radiol"},{"key":"R4-20260914","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1055\/a-1123-7944","article-title":"Low-field magnetic resonance imaging","volume":"192","author":"Klein","year":"2020","journal-title":"Rofo"},{"key":"R5-20260914","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1007\/s00256-024-04597-4","article-title":"Modern low-field MRI","volume":"53","author":"Pogarell","year":"2024","journal-title":"Skeletal Radiol"},{"key":"R6-20260914","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1097\/RLI.0000000000000703","article-title":"Advocating the development of next-generation, advanced-design low-field magnetic resonance systems","volume":"55","author":"Runge","year":"2020","journal-title":"Invest Radiol"},{"key":"R7-20260914","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1002\/jmri.26637","article-title":"Low-field MRI: an MR physics perspective","volume":"49","author":"Marques","year":"2019","journal-title":"J Magn Reson Imaging"},{"key":"R8-20260914","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1097\/RLI.0000000000000810","article-title":"Low-field magnetic resonance imaging: its history and renaissance","volume":"56","author":"Hori","year":"2021","journal-title":"Invest Radiol"},{"key":"R9-20260914","doi-asserted-by":"crossref","first-page":"172","DOI":"10.3389\/fphy.2020.00172","article-title":"Low-field MRI: how low can we go? A fresh view on an old debate","volume":"8","author":"Sarracanie","year":"2020","journal-title":"Front Phys"},{"key":"R10-20260914","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1148\/radiol.2019190452","article-title":"Opportunities in interventional and diagnostic imaging by using high-performance low-field-strength MRI","volume":"293","author":"Campbell-Washburn","year":"2019","journal-title":"Radiology"},{"key":"R11-20260914","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1097\/RLI.0000000000000805","article-title":"Low-field magnetic resonance imaging: a new generation of breakthrough technology in clinical imaging","volume":"56","author":"Heiss","year":"2021","journal-title":"Invest Radiol"},{"key":"R13-20260914","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1007\/s00117-022-00986-9","article-title":"Economic aspects of low-field magnetic resonance imaging: acquisition, installation, and maintenance costs of 0.55 T systems","volume":"62","author":"Vosshenrich","year":"2022","journal-title":"Radiologe"},{"key":"R14-20260914","first-page":"10","article-title":"How to make it big inside and small outside","volume":"78","author":"Biber","year":"2021","journal-title":"MAGNETOM Flash"},{"key":"R16-20260914","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/RLI.0000000000000928","article-title":"Artificial Intelligence-Driven Ultra-Fast Superresolution MRI: 10-Fold Accelerated Musculoskeletal Turbo Spin Echo MRI Within Reach.","volume":"58","author":"Lin","year":"2022","journal-title":"Invest Radiol"},{"key":"R17-20260914","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1007\/s00256-021-03802-y","article-title":"Artificial intelligence in musculoskeletal imaging: a perspective on value propositions, clinical use, and obstacles","volume":"51","author":"Fritz","year":"2022","journal-title":"Skeletal Radiol"},{"key":"R18-20260914","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/RLI.0000000000000811","article-title":"Can deep learning replace gadolinium in neuro-oncology?: a reader study","volume":"57","author":"Ammari","year":"2022","journal-title":"Invest Radiol"},{"key":"R19-20260914","first-page":"29","article-title":"Deep resolve\u2014mobilizing the power of networks","volume":"78","author":"Behl","year":"2021","journal-title":"MAGNETOM Flash"},{"issue":"MAGNETOM Free.Max special issue","key":"R20-20260914","first-page":"11","article-title":"The next generation\u2014advanced design low-field MR systems","author":"Runge","year":"2020","journal-title":"MAGNETOM Flash"},{"key":"R21-20260914","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/RLI.0000000000000912","article-title":"Modern low-field MRI of the musculoskeletal system: practice considerations, opportunities, and challenges","volume":"58","author":"Khodarahmi","year":"2023","journal-title":"Invest Radiol"},{"key":"R23-20260914","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1118\/1.595535","article-title":"A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1\u2013100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age","volume":"11","author":"Bottomley","year":"1984","journal-title":"Med Phys"},{"key":"R24-20260914","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1002\/mrm.29009","article-title":"In vivo T1 and T2 relaxation time maps of brain tissue, skeletal muscle, and lipid measured in healthy volunteers at 50 mT","volume":"87","author":"O\u2019Reilly","year":"2022","journal-title":"Magn Reson Med"},{"key":"R26-20260914","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1002\/mrm.30420","article-title":"Three-dimensional high-isotropic-resolution MR fingerprinting optimized for 0.55 T","volume":"94","author":"Cao","year":"2025","journal-title":"Magn Reson Med"},{"key":"R27-20260914","doi-asserted-by":"crossref","first-page":"e5250","DOI":"10.1002\/nbm.5250","article-title":"Feasibility of 3D MRI fingerprinting for rapid knee cartilage T1, T2, and T1\u03c1 mapping at 0.55T: Comparison with 3T","volume":"37","author":"De Moura","year":"2024","journal-title":"NMR Biomed"},{"key":"R28-20260914","doi-asserted-by":"crossref","first-page":"2447","DOI":"10.1016\/j.acra.2023.07.010","article-title":"Research studies evaluating image quality on commercial 0.55 T MRI systems are essential for sequence optimization and appropriate clinical deployment","volume":"30","author":"Seiberlich","year":"2023","journal-title":"Acad Radiol"},{"key":"R29-20260914","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1002\/jmri.20854","article-title":"Low-field musculoskeletal MRI","volume":"25","author":"Ghazinoor","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"R30-20260914","doi-asserted-by":"crossref","first-page":"2440","DOI":"10.1016\/j.acra.2023.01.037","article-title":"Image quality of lumbar spine imaging at 0.55 T low-field MRI is comparable to conventional 1.5 T MRI\u2013initial observations in healthy volunteers","volume":"30","author":"Breit","year":"2023","journal-title":"Acad Radiol"},{"key":"R31-20260914","doi-asserted-by":"crossref","first-page":"111406","DOI":"10.1016\/j.ejrad.2024.111406","article-title":"Comparison of image quality and diagnostic efficacy of routine clinical lumbar spine imaging at 0.55 T and 1.5\/3T","volume":"175","author":"Lavrova","year":"2024","journal-title":"Eur J Radiol"},{"key":"R32-20260914","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1002\/jmri.10014","article-title":"Evaluation of the rotator cuff and glenoid labrum using a 0.2-Tesla extremity magnetic resonance (MR) system: MR results compared to surgical findings","volume":"14","author":"Shellock","year":"2001","journal-title":"J Magn Reson Imaging"},{"key":"R33-20260914","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1002\/jmri.20040","article-title":"Assessment of the rotator cuff and glenoid labrum using an extremity MR system: MR results compared to surgical findings from a multi-center study","volume":"19","author":"Zlatkin","year":"2004","journal-title":"J Magn Reson Imaging"},{"key":"R34-20260914","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.2214\/ajr.174.4.1741107","article-title":"High-field and low-field MR imaging of superior glenoid labral tears and associated tendon injuries","volume":"174","author":"Tung","year":"2000","journal-title":"Am J Roentgenol"},{"key":"R35-20260914","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0720-048X(98)00134-X","article-title":"Results of a prospective multicenter study for evaluation of the diagnostic quality of an open whole-body low-field MRI unit. A comparison with high-field MRI measured by the applicable gold standard","volume":"30","author":"Merl","year":"1999","journal-title":"Eur J Radiol"},{"key":"R36-20260914","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.2214\/ajr.181.5.1811211","article-title":"Comparison of high-field-strength versus low-field-strength MRI of the shoulder","volume":"181","author":"Magee","year":"2003","journal-title":"Am J Roentgenol"},{"key":"R37-20260914","first-page":"116","article-title":"Role of low field MRI in detecting knee lesions","volume":"90","author":"Leigheb","year":"2018","journal-title":"Acta Biomedica"},{"key":"R38-20260914","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1007\/BF00452088","article-title":"Comparison of low-field (0.2 Tesla) and high-field (1.5 Tesla) magnetic resonance imaging of the knee joint","volume":"114","author":"Kladny","year":"1995","journal-title":"Arch Orthop Trauma Surg"},{"key":"R39-20260914","first-page":"e71277","article-title":"Enhancement of image quality in low-field knee MR imaging using deep learning","volume":"16","author":"Inaoka","year":"2024","journal-title":"Cureus"},{"key":"R40-20260914","doi-asserted-by":"crossref","first-page":"1916","DOI":"10.3390\/jcm12051916","article-title":"Diagnostic image quality of a low-field (0.55 T) knee MRI protocol using deep learning image reconstruction compared with a standard (1.5 T) knee MRI protocol","volume":"12","author":"Lopez Schmidt","year":"2023","journal-title":"J Clin Med"},{"key":"R41-20260914","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1097\/RLI.0000000000001016","article-title":"New-generation 0.55 T MRI of the knee\u2014initial clinical experience and comparison with 3 T MRI","volume":"59","author":"Donners","year":"2024","journal-title":"Invest Radiol"},{"key":"R42-20260914","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1097\/RLI.0000000000001093","article-title":"Deep learning reconstructed new-generation 0.55 t MRI of the knee\u2014a prospective comparison with conventional 3 T MRI","volume":"59","author":"Donners","year":"2024","journal-title":"Invest Radiol"},{"key":"R43-20260914","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1002\/jmri.1880080330","article-title":"MRI of the foot and ankle: diagnostic performance and patient acceptance of a dedicated low field MR scanner","volume":"8","author":"Verhoek","year":"1998","journal-title":"J Magn Reson Imaging"},{"key":"R44-20260914","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1007\/s003300000709","article-title":"MRI of the arthritic small joints: comparison of extremity MRI (0.2 T) vs high-field MRI (1.5 T)","volume":"11","author":"Savnik","year":"2001","journal-title":"Eur Radiol"},{"key":"R45-20260914","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1053\/crad.2000.0657","article-title":"Magnetic resonance imaging of suspected scaphoid fractures using a low field dedicated extremity MR system","volume":"56","author":"Raby","year":"2001","journal-title":"Clin Radiol"},{"key":"R46-20260914","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1097\/RLI.0000000000000866","article-title":"New-generation low-field magnetic resonance imaging of hip arthroplasty implants using slice encoding for metal artifact correction: first in vitro experience at 0.55 T and comparison with 1.5 T","volume":"57","author":"Khodarahmi","year":"2022","journal-title":"Invest Radiol"},{"key":"R47-20260914","doi-asserted-by":"crossref","first-page":"106758","DOI":"10.1016\/j.crad.2024.106758","article-title":"New-generation 0.55T MRI in patients with total hip arthroplasty: a comparison with 1.5T MRI","volume":"81","author":"Breit","year":"2025","journal-title":"Clin Radiol"},{"key":"R48-20260914","doi-asserted-by":"crossref","first-page":"111524","DOI":"10.1016\/j.ejrad.2024.111524","article-title":"Diagnosing periprosthetic hip joint infection with new-generation 0.55T MRI","volume":"176","author":"Plesniar","year":"2024","journal-title":"Eur J Radiol"},{"key":"R49-20260914","doi-asserted-by":"crossref","first-page":"e68","DOI":"10.1055\/s-0039-1687898","article-title":"Metal about the hip and artifact reduction techniques: from basic concepts to advanced imaging","volume":"23","author":"Khodarahmi","year":"2019","journal-title":"Semin Musculoskelet Radiol"},{"key":"R50-20260914","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1055\/s-0037-1606135","article-title":"Leaps in technology: advanced MR imaging after total hip arthroplasty","volume":"21","author":"Khodarahmi","year":"2017","journal-title":"Semin Musculoskelet Radiol"},{"key":"R51-20260914","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1097\/RLI.0000000000000317","article-title":"Compressed sensing SEMAC: 8-fold accelerated high resolution metal artifact reduction MRI of cobalt-chromium knee arthroplasty implants","volume":"51","author":"Fritz","year":"2016","journal-title":"Invest Radiol"},{"key":"R52-20260914","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1002\/mrm.30438","article-title":"Imaging near titanium total hip arthroplasty at 0.55\u00a0T compared with 3\u00a0T","volume":"94","author":"Keskin","year":"2025","journal-title":"Magn Reson Med"},{"key":"R53-20260914","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/s40634-020-00274-2","article-title":"The diagnostic potential of low-field MRI in problematic total knee arthroplasties\u2014a feasibility study","volume":"7","author":"Schr\u00f6der","year":"2020","journal-title":"J Exp Orthop"},{"key":"R54-20260914","doi-asserted-by":"crossref","first-page":"2456","DOI":"10.1016\/j.acra.2023.12.048","article-title":"Comparing metal artifact severity and ability to assess near-metal anatomy between 0.55 T and 1.5 T MRI in patients with metallic spinal implants\u2014a scanner comparison study","volume":"31","author":"Seifert","year":"2024","journal-title":"Acad Radiol"},{"key":"R55-20260914","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1007\/s00256-020-03597-4","article-title":"Metal artifacts of hip arthroplasty implants at 1.5-T and 3.0-T: a closer look into the B1 effects","volume":"50","author":"Khodarahmi","year":"2021","journal-title":"Skeletal Radiol"},{"key":"R56-20260914","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1097\/RLI.0000000000000376","article-title":"Simultaneous multislice accelerated turbo spin echo magnetic resonance imaging: comparison and combination with in-plane parallel imaging acceleration for high-resolution magnetic resonance imaging of the knee","volume":"52","author":"Fritz","year":"2017","journal-title":"Invest Radiol"},{"key":"R57-20260914","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1148\/radiol.2021203655","article-title":"Five-minute five-sequence knee MRI using combined simultaneous multislice and parallel imaging acceleration: comparison with 10-minute parallel imaging knee MRI","volume":"299","author":"Del Grande","year":"2021","journal-title":"Radiology"},{"key":"R58-20260914","doi-asserted-by":"crossref","first-page":"6705","DOI":"10.3390\/jcm11226705","article-title":"More space, less noise\u2014new-generation low-field magnetic resonance imaging systems can improve patient comfort: a prospective 0.55 T\u20131.5 T-scanner comparison","volume":"11","author":"Rusche","year":"2022","journal-title":"J Clin Med"},{"key":"R59-20260914","doi-asserted-by":"crossref","first-page":"e36069","DOI":"10.1097\/MD.0000000000036069","article-title":"Does bore size matter?\u2014a comparison of the subjective perception of patient comfort during low field (0.55 Tesla) and standard (1.5 Tesla) MRI imaging","volume":"102","author":"Michael","year":"2023","journal-title":"Medicine"},{"key":"R60-20260914","first-page":"1","article-title":"New clinical opportunities of low-field MRI: heart, lung, body, and musculoskeletal","volume":"37","author":"Tian","year":"2024","journal-title":"MAGMA"},{"key":"R61-20260914","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1002\/jmri.25858","article-title":"Instrument visualization using conventional and compressed sensing SEMAC for interventional MRI at 3 T","volume":"47","author":"Sonnow","year":"2018","journal-title":"J Magn Reson Imaging"},{"key":"R63-20260914","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.3390\/diagnostics15111413","article-title":"Real-time MR-guided lumbosacral periradicular injection therapy using a 0.55 T MRI system: a phantom study","volume":"15","author":"Saeed","year":"2025","journal-title":"Diagnostics"},{"key":"R64-20260914","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1002\/jmri.28890","article-title":"Cardiac MRI at low field strengths","volume":"59","author":"Campbell-Washburn","year":"2024","journal-title":"J Magn Reson Imaging"},{"key":"R65-20260914","doi-asserted-by":"crossref","first-page":"3773","DOI":"10.1007\/s00261-024-04783-x","article-title":"Clinical feasibility of MRI-guided in-bore prostate biopsies at 0.55T","volume":"50","author":"Kaur","year":"2025","journal-title":"Abdom Radiol"},{"key":"R66-20260914","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1097\/RLI.0000000000000649","article-title":"Needle heating during interventional magnetic resonance imaging at 1.5- and 3.0-T field strengths","volume":"55","author":"Khodarahmi","year":"2020","journal-title":"Invest Radiol"},{"key":"R67-20260914","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1097\/RLI.0000000000000732","article-title":"Heating of hip arthroplasty implants during metal artifact reduction MRI at 1.5- and 3.0-T field strengths","volume":"56","author":"Khodarahmi","year":"2021","journal-title":"Invest Radiol"},{"key":"R68-20260914","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1007\/s10334-023-01099-7","article-title":"RF-induced heating of interventional devices at 23.66 MHz","volume":"36","author":"\u00d6zen","year":"2023","journal-title":"MAGMA"},{"key":"R69-20260914","doi-asserted-by":"crossref","first-page":"20230298","DOI":"10.1259\/bjr.20230298","article-title":"Real-time MRI of the moving wrist at 0.55 Tesla","volume":"96","author":"Chaudhari","year":"2023","journal-title":"Br J Radiol"},{"key":"R70-20260914","first-page":"74","article-title":"Musculoskeletal perturbations of deep space radiation: assessment using a Gateway MRI","volume":"42","author":"Jullienne","year":"2024","journal-title":"Life Sci Space Res"},{"key":"R71-20260914","doi-asserted-by":"crossref","first-page":"1995","DOI":"10.1002\/mrm.30199","article-title":"Fat suppression using frequency-sweep RF saturation and iterative reconstruction","volume":"92","author":"Zi","year":"2024","journal-title":"Magn Reson Med"},{"key":"R72-20260914","doi-asserted-by":"crossref","first-page":"5772","DOI":"10.1007\/s00261-021-03234-1","article-title":"Diagnostic abdominal MR imaging on a prototype low-field 0.55 T scanner operating at two different gradient strengths","volume":"46","author":"Chandarana","year":"2021","journal-title":"Abdom Radiol"},{"key":"R73-20260914","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1002\/mrm.22578","article-title":"Dual-echo Dixon imaging with flexible choice of echo times","volume":"65","author":"Eggers","year":"2011","journal-title":"Magn Reson Med"},{"key":"R74-20260914","doi-asserted-by":"crossref","first-page":"343","DOI":"10.2214\/ajr.183.2.1830343","article-title":"Musculoskeletal MRI at 3.0 T: relaxation times and image contrast","volume":"183","author":"Gold","year":"2004","journal-title":"Am J Roentgenol"},{"key":"R75-20260914","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1097\/01.rli.0000184756.66360.d3","article-title":"Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths","volume":"40","author":"Rohrer","year":"2005","journal-title":"Invest Radiol"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001879","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T21:00:26Z","timestamp":1789419626000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001879"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,11]]},"references-count":70,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001879","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5,11]]},"assertion":[{"value":"2025-11-12","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}