{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T21:06:48Z","timestamp":1789420008781,"version":"build-2803163510"},"reference-count":49,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>As applications of MRI in the abdomen and pelvis have increased, access to MRI scanners has become more crucial. 0.55\u00a0T MRI scanners can potentially improve access by reducing the costs of MR systems and simplifying their siting requirements. These savings come with important tradeoffs, most notably decreased SNR efficiency. Decreases in SNR can be ameliorated to some degree by shorter T1 (faster repetition time), longer T2* (reduced susceptibility artifacts), and higher gadolinium relaxivity, which are found at lower fields. Reduced frequency separation between fat and water presents a particular challenge in imaging the abdomen and pelvis. In this article, we review how MRI at 0.55\u00a0T affects abdominal and pelvic imaging and discuss clinical examples of the liver, kidney, bile ducts, uterus, and ovary. We illustrate how metal artifacts are reduced at 0.55\u00a0T and discuss how deep learning image reconstructions, combined with free-breathing techniques, can overcome some of the limitations imposed by reduced SNR. We discuss future challenges and opportunities in this field, leveraging technological advances from other fields to bring MRI to more people who need it.<\/jats:p>","DOI":"10.1097\/rct.0000000000001895","type":"journal-article","created":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T18:00:36Z","timestamp":1782410436000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["0.55 T Magnetic Resonance Imaging in the Abdomen and Pelvis: Opportunities and Challenges"],"prefix":"10.1097","volume":"50","author":[{"given":"Michael A.","family":"Ohliger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9]]},"reference":[{"key":"R1-20260914","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1002\/jmri.29750","article-title":"Accelerated abdominal MRI: a review of current methods and applications","volume":"62","author":"Feng","year":"2025","journal-title":"Magn Reson Imaging"},{"key":"R2-20260914","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1148\/radiol.2018172765","article-title":"Quantitative MRI of diffuse liver disease: current applications and future directions","volume":"290","author":"Curtis","year":"2019","journal-title":"Radiology"},{"key":"R3-20260914","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1007\/s00261-019-02382-9","article-title":"T1 mapping, T2 mapping and MR elastography of the liver for detection and staging of liver fibrosis","volume":"45","author":"Hoffman","year":"2020","journal-title":"Abdom Radiol"},{"key":"R4-20260914","doi-asserted-by":"crossref","first-page":"e5022","DOI":"10.1002\/nbm.5022","article-title":"MRI scarcity in low- and middle-income countries","volume":"36","author":"Jalloul","year":"2023","journal-title":"NMR Biomed"},{"issue":"12, Part A","key":"R5-20260914","doi-asserted-by":"crossref","first-page":"1536","DOI":"10.1016\/j.jacr.2016.07.038","article-title":"The MRI helium crisis: past and future","volume":"13","author":"Mahesh","year":"2016","journal-title":"Journal of the American College of Radiology"},{"key":"R6-20260914","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1146\/annurev-bioeng-110122-022903","article-title":"Low-field, low-cost, point-of-care magnetic resonance imaging","volume":"26","author":"Samardzija","year":"2024","journal-title":"Annu Rev Biomed Eng"},{"key":"R7-20260914","doi-asserted-by":"crossref","first-page":"e230073","DOI":"10.1148\/rg.230073","article-title":"Low-field-strength body MRI: challenges and opportunities at 0.55\u00a0T","volume":"43","author":"Shetty","year":"2023","journal-title":"Radiographics"},{"key":"R8-20260914","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1148\/radiology.179.3.2027973","article-title":"Focal hepatic lesions: differentiation with MR imaging at 0.5\u00a0T","volume":"179","author":"Brown","year":"1991","journal-title":"Radiology"},{"issue":"pt 1","key":"R9-20260914","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1148\/radiology.170.1.2909089","article-title":"Liver metastases: detection with MR imaging at 0.5 and 1.5\u00a0T","volume":"170","author":"Reinig","year":"1989","journal-title":"Radiology"},{"key":"R10-20260914","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1007\/s003300050295","article-title":"MR cholangiopancreatography at 0.5\u00a0T with a 3D inversion recovery turbo-spin-echo sequence","volume":"7","author":"Chrysikopoulos","year":"1997","journal-title":"Eur Radiol"},{"key":"R11-20260914","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1002\/mrm.1910100207","article-title":"Snapshot imaging at 0.5\u00a0T using echo-planar techniques","volume":"10","author":"Ordidge","year":"1989","journal-title":"Magn Reson Med"},{"issue":"pt 1","key":"R12-20260914","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1148\/radiology.170.1.2909106","article-title":"Whole-body echo-planar MR imaging at 0.5\u00a0T","volume":"170","author":"Stehling","year":"1989","journal-title":"Radiology"},{"key":"R13-20260914","doi-asserted-by":"crossref","first-page":"20210708","DOI":"10.1259\/bjr.20210708","article-title":"3\u00a0T: the good, the bad, and the ugly","volume":"95","author":"Graves","year":"2022","journal-title":"Br J Radiol"},{"key":"R14-20260914","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/0022-2364(79)90019-2","article-title":"The sensitivity of the zeugmatographic experiment involving human samples","volume":"34","author":"Hoult","year":"1979","journal-title":"Journal of Magnetic Resonance (1969)"},{"key":"R15-20260914","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1002\/mrm.30515","article-title":"Comparative study of radiofrequency heating in deep brain stimulation devices during MRI at 1.5\u00a0T and 0.55\u00a0T: Challenging the assumption of safety at low field strengths","volume":"94","author":"Bhusal","year":"2025","journal-title":"Magn Reson Med"},{"key":"R16-20260914","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/RMR.0b013e3180f612b3","article-title":"High-field-strength magnetic resonance: potential and limits","volume":"18","author":"Ladd","year":"2007","journal-title":"Top Magn Reson Imaging"},{"key":"R17-20260914","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1007\/s00247-023-05604-x","article-title":"Low-field 0.55\u00a0T MRI evaluation of the fetus","volume":"53","author":"Ponrartana","year":"2023","journal-title":"Pediatr Radiol"},{"key":"R18-20260914","doi-asserted-by":"crossref","first-page":"3177","DOI":"10.1016\/j.acra.2024.01.018","article-title":"Abdominal MRI on a commercial 0.55\u00a0T system: initial evaluation and comparison to higher field strengths","volume":"31","author":"Ramachandran","year":"2024","journal-title":"Acad Radiol"},{"key":"R19-20260914","doi-asserted-by":"crossref","first-page":"1114","DOI":"10.1002\/mrm.29682","article-title":"Body composition profiling at 0.55\u00a0T: feasibility and precision","volume":"90","author":"Nayak","year":"2023","journal-title":"Magn Reson Med"},{"key":"R20-20260914","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1148\/radiol.2019190452","article-title":"Opportunities in interventional and diagnostic imaging by using high-performance low-field-strength MRI","volume":"293","author":"Campbell-Washburn","year":"2019","journal-title":"Radiology"},{"key":"R21-20260914","doi-asserted-by":"crossref","first-page":"8106","DOI":"10.1038\/s41598-019-44377-y","article-title":"Liver MR relaxometry at 3\u00a0T\u2013segmental normal T1 and T2* values in patients without focal or diffuse liver disease and in patients with increased liver fat and elevated liver stiffness","volume":"9","author":"Obmann","year":"2019","journal-title":"Sci Rep"},{"key":"R22-20260914","first-page":"2580","article-title":"Improved abdominal T1 weighted imaging at 0.55\u00a0T","volume":"92","author":"Tasdelen","year":"2024","journal-title":"Magn Reson Med"},{"key":"R23-20260914","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.mri.2020.12.002","article-title":"Susceptibility artifacts from metallic markers and cardiac catheterization devices on a high-performance 0.55\u00a0T MRI system","volume":"77","author":"Basar","year":"2021","journal-title":"Magn Reson Imaging"},{"key":"R24-20260914","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1002\/mrm.29885","article-title":"Real-time water\/fat imaging at 0.55\u00a0T with spiral out-in-out-in sampling","volume":"91","author":"Tian","year":"2024","journal-title":"Magn Reson Med"},{"key":"R25-20260914","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1148\/radiographics.18.6.9821195","article-title":"Detection of lipid in abdominal tissues with opposed-phase gradient-echo images at 1.5\u00a0T: techniques and diagnostic importance","volume":"18","author":"Outwater","year":"1998","journal-title":"Radiographics"},{"key":"R26-20260914","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1007\/s003300050781","article-title":"Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents","volume":"9","author":"Rinck","year":"1999","journal-title":"Eur Radiol"},{"key":"R27-20260914","doi-asserted-by":"crossref","first-page":"e4921","DOI":"10.1002\/nbm.4921","article-title":"Superconducting magnet designs and MRI accessibility: a review","volume":"36","author":"Manso Jimeno","year":"2023","journal-title":"NMR Biomed"},{"key":"R28-20260914","doi-asserted-by":"crossref","first-page":"1901","DOI":"10.1002\/mrm.29316","article-title":"Systematic dimensional analysis of the scaling relationship for gradient and shim coil design parameters","volume":"88","author":"Lee","year":"2022","journal-title":"Magn Reson Med"},{"key":"R29-20260914","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1002\/mrm.70077","article-title":"Acceleration of slice encoding for metal artifact correction at 0.55\u00a0T using hexagonal sampling","volume":"95","author":"Barlas","year":"2025","journal-title":"Magn Reson Med"},{"key":"R31-20260914","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.diii.2024.09.008","article-title":"Deep learning reconstruction for accelerated high-resolution upper abdominal MRI improves lesion detection without a time penalty","volume":"106","author":"Brendel","year":"2025","journal-title":"Diagnostic and Interventional Imaging"},{"key":"R32-20260914","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/j.jfma.2024.10.017","article-title":"Application of deep learning reconstruction in abdominal magnetic resonance cholangiopancreatography for image quality improvement and acquisition time reduction","volume":"124","author":"Chen","year":"2025","journal-title":"J Formos Med Assoc"},{"key":"R33-20260914","doi-asserted-by":"crossref","first-page":"1619","DOI":"10.1002\/mrm.70155","article-title":"Self-supervised noise adaptive MRI denoising via repetition to repetition (Rep2Rep) learning","volume":"95","author":"Janju\u0161evi\u0107","year":"2026","journal-title":"Magn Reson Med"},{"key":"R34-20260914","doi-asserted-by":"crossref","first-page":"7049","DOI":"10.1016\/j.acra.2025.08.013","article-title":"Deep learning-enhanced single breath-hold abdominal MRI at 0.55\u00a0T\u2014technical feasibility and image quality assessment","volume":"32","author":"Seifert","year":"2025","journal-title":"Acad Radiol"},{"key":"R35-20260914","doi-asserted-by":"crossref","first-page":"e2532888","DOI":"10.2214\/AJR.25.32888","article-title":"Flip angle optimization for hepatobiliary phase MRI at 0.55\u00a0T in patients with metastatic neuroendocrine tumors: a prospective study","volume":"225","author":"Hong","year":"2025","journal-title":"AJR Am J Roentgenol"},{"key":"R36-20260914","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.eururo.2019.02.033","article-title":"Prostate imaging reporting and data system version 2.1: 2019 update of prostate imaging reporting and data system version 2","volume":"76","author":"Turkbey","year":"2019","journal-title":"Eur Urol"},{"key":"R37-20260914","doi-asserted-by":"crossref","first-page":"e96619","DOI":"10.1371\/journal.pone.0096619","article-title":"High b value (2000\u00a0s\/mm2) diffusion-weighted magnetic resonance imaging in prostate cancer at 3 Tesla: comparison with 1000\u00a0s\/mm2 for tumor conspicuity and discrimination of aggressiveness","volume":"9","author":"Tamada","year":"2014","journal-title":"PLoS ONE"},{"key":"R38-20260914","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.acra.2020.09.016","article-title":"Whole-body MRI with an ultrahigh b-value of 2000\u00a0s\/mm2 Improves the specificity of diffusion-weighted imaging in patients with plasma cell dyscrasias","volume":"29","author":"Heidemeier","year":"2022","journal-title":"Acad Radiol"},{"key":"R39-20260914","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.3348\/jksr.2022.0004","article-title":"Comparison of computed diffusion-weighted imaging b2000 and acquired diffusion-weighted imaging b2000 for detection of prostate cancer","volume":"83","author":"Kim","year":"2022","journal-title":"J Korean Soc Radiol"},{"key":"R40-20260914","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2214\/AJR.25.33252","article-title":"MRI at 0.55\u00a0T for assessment of pancreatic intraductal papillary mucinous neoplasms: an intraindividual comparison versus 1.5\u00a0T and 3\u00a0T MRI","volume":"225","author":"Rajeev","year":"2025","journal-title":"AJR Am J Roentgenol"},{"key":"R41-20260914","doi-asserted-by":"crossref","first-page":"103352","DOI":"10.1016\/j.media.2024.103352","article-title":"Fetal body organ T2* relaxometry at low field strength (FOREST)","volume":"99","author":"Payette","year":"2025","journal-title":"Med Image Anal"},{"key":"R43-20260914","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.placenta.2025.10.014","article-title":"Low-field combined diffusion-relaxation MRI for mapping placenta structure and function","volume":"172","author":"Slator","year":"2025","journal-title":"Placenta"},{"key":"R44-20260914","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1097\/RMR.0000000000000141","article-title":"Fat quantification in the abdomen","volume":"26","author":"Hong","year":"2017","journal-title":"Top Magn Reson Imaging"},{"key":"R45-20260914","doi-asserted-by":"crossref","first-page":"e220181","DOI":"10.1148\/rg.220181","article-title":"Liver fibrosis, fat, and iron evaluation with MRI and fibrosis and fat evaluation with US: a practical guide for radiologists","volume":"43","author":"Guglielmo","year":"2023","journal-title":"Radiographics"},{"key":"R46-20260914","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1002\/mrm.28679","article-title":"Magnetization-prepared GRASP MRI for rapid 3D T1 mapping and fat\/water-separated T1 mapping","volume":"86","author":"Feng","year":"2021","journal-title":"Magn Reson Med"},{"key":"R47-20260914","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1007\/s10334-025-01277-9","article-title":"In-vivo liver proton density fat fraction quantification at 0.55\u00a0T: a pilot study with comparison against 3\u00a0T MRI","volume":"38","author":"Wong","year":"2025","journal-title":"Magn Reson Mater Phy"},{"key":"R48-20260914","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1002\/mrm.70057","article-title":"Liver fat quantification at 0.55\u00a0T enabled by locally low-rank enforced deep learning reconstruction","volume":"95","author":"Helo","year":"2026","journal-title":"Magn Reson Med"},{"key":"R49-20260914","first-page":"799","article-title":"Feasibility of liver MR elastography at 0.55\u00a0T","volume":"33","author":"Ohliger","year":"2025","journal-title":"In: Proceedings of the International Society of Magnetic Resonance"},{"key":"R51-20260914","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1148\/radiol.2018181494","article-title":"Liver Imaging Reporting and Data System (LI-RADS) version 2018: imaging of hepatocellular carcinoma in at-risk patients","volume":"289","author":"Chernyak","year":"2018","journal-title":"Radiology"},{"key":"R52-20260914","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1148\/radiol.204371","article-title":"O-RADS MRI risk stratification system: guide for assessing adnexal lesions from the ACR O-RADS Committee","volume":"303","author":"Sadowski","year":"2022","journal-title":"Radiology"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001895","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T21:00:29Z","timestamp":1789419629000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001895"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,25]]},"references-count":49,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001895","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6,25]]},"assertion":[{"value":"2026-01-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}