{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T11:50:23Z","timestamp":1792065023657,"version":"4.4.0"},"reference-count":49,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Magnetic resonance imaging (MRI) is integral to modern clinical practice owing to its superior soft-tissue contrast. However, the complexity of MRI physics predisposes examinations to numerous artifacts that may mimic pathology, obscure disease, or lead to misinterpretation in routine clinical settings. Failure to recognize these artifacts can result in diagnostic error, unnecessary additional imaging, or inappropriate clinical management. This practical review categorizes commonly encountered MRI artifacts by underlying mechanisms and highlights their typical imaging appearances across routine clinical applications. Emphasis is placed on differentiating artifacts from true pathology and on providing actionable strategies for artifact recognition, troubleshooting, and prevention during image acquisition and interpretation. By integrating imaging examples with clinically relevant explanations of the underlying physics, this review aims to equip practicing radiologists and trainees with a structured approach to confidently identify misleading findings and improve diagnostic accuracy in everyday practice.<\/jats:p>","DOI":"10.1097\/rct.0000000000001908","type":"journal-article","created":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T11:01:17Z","timestamp":1792062077000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["MRI Artifacts in Clinical Practice: Recognition, Pitfalls, and Practical Solutions"],"prefix":"10.1097","author":[{"given":"Jonathan","family":"Gan","sequence":"first","affiliation":[{"name":"Department of Radiology, Northwestern University- Feinberg School of Medicine, Chicago, IL"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ananya","family":"Panda","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, IA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yashant","family":"Aswani","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, IA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Judy R.","family":"James","sequence":"additional","affiliation":[{"name":"Department of Radiology, Loyola University Medical Center, Maywood, IL"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prabhakaran","family":"A.V","sequence":"additional","affiliation":[{"name":"Department of Radiology, Nandha Medical College, Perundurai Road, Erode, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1541-7568","authenticated-orcid":false,"given":"Anu P.","family":"Gayathri","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University- Feinberg School of Medicine, Chicago, IL"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,10,15]]},"reference":[{"key":"R1-20261015","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1148\/rg.313105115","article-title":"An image-based approach to understanding the physics of MR artifacts","volume":"31","author":"Morelli","year":"2011","journal-title":"Radiographics"},{"key":"R2-20261015","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.2214\/ajr.143.6.1175","article-title":"Magnetic resonance imaging with respiratory gating: techniques and advantages","volume":"143","author":"Ehman","year":"1984","journal-title":"AJR Am J Roentgenol"},{"key":"R3-20261015","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1148\/radiology.198.1.8539406","article-title":"Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography","volume":"198","author":"Wang","year":"1996","journal-title":"Radiology"},{"key":"R4-20261015","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1002\/jmri.24850","article-title":"Motion artifacts in MRI: a complex problem with many partial solutions","volume":"42","author":"Zaitsev","year":"2015","journal-title":"J Magn Reson Imaging"},{"key":"R5-20261015","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.2214\/AJR.14.13677","article-title":"Transient respiratory motion artifact during arterial phase MRI with gadoxetate disodium: risk factor analyses","volume":"204","author":"Kim","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"R6-20261015","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1148\/radiol.2016160241","article-title":"Reducing artifacts during arterial phase of gadoxetate disodium-enhanced MR imaging: dilution method versus reduced injection rate","volume":"283","author":"Kim","year":"2017","journal-title":"Radiology"},{"key":"R7-20261015","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1055\/s-0043-120116","article-title":"Transient severe respiratory motion artifacts after application of gadoxetate disodium: what we currently know","volume":"190","author":"Well","year":"2018","journal-title":"Rofo"},{"key":"R8-20261015","doi-asserted-by":"crossref","first-page":"105704","DOI":"10.1016\/j.ejmp.2025.105704","article-title":"Systematic review and meta-analysis of AI-driven MRI motion artifact detection and correction","volume":"141","author":"Safari","year":"2026","journal-title":"Phys Med"},{"key":"R9-20261015","doi-asserted-by":"crossref","first-page":"e230200","DOI":"10.1148\/rg.230200","article-title":"Artifacts at cardiac MRI: imaging appearances and solutions","volume":"45","author":"Rajiah","year":"2025","journal-title":"Radiographics"},{"key":"R10-20261015","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.mric.2014.08.004","article-title":"MR physics in practice: how to optimize acquisition quality and time for cardiac MR imaging","volume":"23","author":"Saloner","year":"2015","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"R11-20261015","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1186\/s13244-021-01125-z","article-title":"Magnetism of materials: theory and practice in magnetic resonance imaging","volume":"12","author":"Gaeta","year":"2021","journal-title":"Insights Imaging"},{"key":"R12-20261015","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/0895-6111(90)90040-I","article-title":"Effect of field strength on susceptibility artifacts in magnetic resonance imaging","volume":"14","author":"Farahani","year":"1990","journal-title":"Comput Med Imaging Graph"},{"key":"R13-20261015","doi-asserted-by":"crossref","first-page":"547","DOI":"10.2214\/AJR.11.7364","article-title":"Metal-induced artifacts in MRI","volume":"197","author":"Hargreaves","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"R14-20261015","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1007\/s00256-024-04624-4","article-title":"Managing hardware-related metal artifacts in MRI: current and evolving techniques","volume":"53","author":"Feuerriegel","year":"2024","journal-title":"Skeletal Radiol"},{"key":"R15-20261015","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1002\/jmri.25708","article-title":"Advances in MRI around metal","volume":"46","author":"Jungmann","year":"2017","journal-title":"J Magn Reson Imaging"},{"key":"R16-20261015","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.ejrad.2017.12.020","article-title":"Gas-induced susceptibility artefacts on diffusion-weighted MRI of the rectum at 1.5\u202fT\u2014effect of applying a micro-enema to improve image quality","volume":"99","author":"van Griethuysen","year":"2018","journal-title":"Eur J Radiol"},{"key":"R17-20261015","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.ejrad.2007.11.005","article-title":"Artifacts in 3-T MRI: physical background and reduction strategies","volume":"65","author":"Dietrich","year":"2008","journal-title":"Eur J Radiol"},{"key":"R18-20261015","doi-asserted-by":"crossref","first-page":"369","DOI":"10.2214\/AJR.12.10394","article-title":"Application of basic physics principles to clinical neuroradiology: differentiating artifacts from true pathology on MRI","volume":"201","author":"Hakky","year":"2013","journal-title":"AJR Am J Roentgenol"},{"key":"R19-20261015","doi-asserted-by":"crossref","first-page":"kkae013","DOI":"10.1093\/psyrad\/kkae013","article-title":"Advancements in MR hardware systems and magnetic field control: B0 shimming, RF coils, and gradient techniques for enhancing magnetic resonance imaging and spectroscopy","volume":"4","author":"Shang","year":"2024","journal-title":"Psychoradiology"},{"key":"R20-20261015","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1097\/00002142-199602000-00006","article-title":"The magic angle effect in musculoskeletal MR imaging","volume":"8","author":"Hayes","year":"1996","journal-title":"Top Magn Reson Imaging"},{"key":"R21-20261015","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1002\/jmri.20850","article-title":"The magic angle effect: a source of artifact, determinant of image contrast, and technique for imaging","volume":"25","author":"Bydder","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"R22-20261015","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1148\/radiographics.19.2.g99mr07357","article-title":"Chemical shift: the artifact and clinical tool revisited","volume":"19","author":"Hood","year":"1999","journal-title":"Radiographics"},{"key":"R23-20261015","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.mric.2005.12.001","article-title":"Abdominal MR imaging at 3T","volume":"14","author":"Merkle","year":"2006","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"R24-20261015","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1148\/rg.2015140289","article-title":"Body MR imaging: artifacts, k-Space, and solutions","volume":"35","author":"Huang","year":"2015","journal-title":"Radiographics"},{"key":"R25-20261015","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1148\/radiology.153.1.6089263","article-title":"Simple proton spectroscopic imaging","volume":"153","author":"Dixon","year":"1984","journal-title":"Radiology"},{"key":"R26-20261015","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1002\/jmri.21492","article-title":"Dixon techniques for water and fat imaging","volume":"28","author":"Ma","year":"2008","journal-title":"J Magn Reson Imaging"},{"key":"R27-20261015","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1148\/rg.2016150133","article-title":"Spectrum of fat-containing soft-tissue masses at MR imaging: the common, the uncommon, the characteristic, and the sometimes confusing","volume":"36","author":"Gupta","year":"2016","journal-title":"Radiographics"},{"key":"R28-20261015","doi-asserted-by":"crossref","first-page":"93","DOI":"10.12659\/PJR.892628","article-title":"Artifacts in magnetic resonance imaging","volume":"80","author":"Krupa","year":"2015","journal-title":"Pol J Radiol"},{"key":"R29-20261015","doi-asserted-by":"crossref","first-page":"1396","DOI":"10.2214\/AJR.07.2874","article-title":"An introduction to the Fourier transform: relationship to MRI","volume":"190","author":"Gallagher","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"R30-20261015","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1093\/pm\/pnab346","article-title":"Gibbs or truncation artifact on MRI mimicking degenerative cervical myelopathy","volume":"23","author":"Phillips","year":"2022","journal-title":"Pain Med"},{"key":"R31-20261015","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/0895-6111(86)90003-0","article-title":"Aliasing artifacts in MR imaging","volume":"12","author":"Pusey","year":"1988","journal-title":"Comput Med Imaging Graph"},{"key":"R32-20261015","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1002\/jmri.28187","article-title":"Golden-angle radial MRI: basics, advances, and applications","volume":"56","author":"Feng","year":"2022","journal-title":"J Magn Reson Imaging"},{"key":"R33-20261015","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1002\/mrm.23023","article-title":"Automatic coil selection for streak artifact reduction in radial MRI","volume":"67","author":"Xue","year":"2012","journal-title":"Magn Reson Med"},{"key":"R34-20261015","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1002\/jmri.24288","article-title":"Body MRI artifacts in clinical practice: a physicist\u2019s and radiologist\u2019s perspective","volume":"38","author":"Graves","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"R35-20261015","doi-asserted-by":"crossref","first-page":"33","DOI":"10.25259\/JCIS_74_2024","article-title":"Radiofrequency interference in magnetic resonance imaging: Identification and rectification","volume":"14","author":"Kwok","year":"2024","journal-title":"J Clin Imaging Sci"},{"key":"R36-20261015","doi-asserted-by":"crossref","first-page":"20150987","DOI":"10.1259\/bjr.20150987","article-title":"Current artefacts in cardiac and chest magnetic resonance imaging: tips and tricks","volume":"89","author":"Alfudhili","year":"2016","journal-title":"Br J Radiol"},{"key":"R38-20261015","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1148\/radiographics.20.3.g00ma19893","article-title":"Signal intensity artifacts in clinical MR imaging","volume":"20","author":"Jones","year":"2000","journal-title":"Radiographics"},{"key":"R39-20261015","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s002560100341","article-title":"Artifacts in musculoskeletal magnetic resonance imaging: identification and correction","volume":"30","author":"Peh","year":"2001","journal-title":"Skeletal Radiol"},{"key":"R40-20261015","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1002\/mrm.24433","article-title":"Permittivity and performance of dielectric pads with sintered ceramic beads in MRI: early experiments and simulations at 3 T","volume":"70","author":"Luo","year":"2013","journal-title":"Magn Reson Med"},{"key":"R41-20261015","doi-asserted-by":"crossref","first-page":"E102","DOI":"10.1148\/rg.210021","article-title":"Primer on commonly occurring MRI artifacts and how to overcome them","volume":"42","author":"Noda","year":"2022","journal-title":"Radiographics"},{"key":"R42-20261015","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1097\/00004728-198709000-00022","article-title":"Spinal MR imaging: multiplanar representation from a single high resolution 3D acquisition","volume":"11","author":"Sherry","year":"1987","journal-title":"J Comput Assist Tomogr"},{"key":"R43-20261015","doi-asserted-by":"crossref","first-page":"5204","DOI":"10.1118\/1.4738965","article-title":"Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence","volume":"39","author":"Chen","year":"2012","journal-title":"Med Phys"},{"key":"R44-20261015","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1016\/j.mri.2013.03.006","article-title":"Elimination of motion, pulsatile flow and cross-talk artifacts using blade sequences in lumbar spine MR imaging","volume":"31","author":"Lavdas","year":"2013","journal-title":"Magn Reson Imaging"},{"key":"R45-20261015","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1038\/s44303-025-00076-0","article-title":"A critical assessment of artificial intelligence in magnetic resonance imaging of cancer","volume":"3","author":"Wu","year":"2025","journal-title":"Npj Imaging"},{"key":"R46-20261015","doi-asserted-by":"crossref","first-page":"4736","DOI":"10.1007\/s00330-025-11423-5","article-title":"The scientific evidence of commercial AI products for MRI acceleration: a systematic review","volume":"35","author":"Fransen","year":"2025","journal-title":"Eur Radiol"},{"key":"R47-20261015","first-page":"e94561","article-title":"Examining the effect of deep learning-based image reconstruction on accelerating shoulder magnetic resonance imaging (MRI) and its impact on image quality","volume":"17","author":"Sim","year":"2025","journal-title":"Cureus"},{"key":"R48-20261015","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1002\/jmri.20683","article-title":"Artifacts and pitfalls in diffusion MRI","volume":"24","author":"Le Bihan","year":"2006","journal-title":"J Magn Reson Imaging"},{"key":"R49-20261015","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1002\/mrm.22024","article-title":"High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition","volume":"62","author":"Porter","year":"2009","journal-title":"Magn Reson Med"},{"key":"R50-20261015","doi-asserted-by":"crossref","first-page":"027001","DOI":"10.1088\/2057-1976\/ada8b0","article-title":"Nyquist ghost elimination for diffusion MRI by dual-polarity readout at low b-values","volume":"11","author":"Jalnefjord","year":"2025","journal-title":"Biomed Phys Eng Express"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001908","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T11:01:23Z","timestamp":1792062083000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/RCT.0000000000001908"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,15]]},"references-count":49,"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001908","relation":{},"ISSN":["1532-3145","0363-8715"],"issn-type":[{"value":"1532-3145","type":"electronic"},{"value":"0363-8715","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10,15]]},"assertion":[{"value":"2026-02-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-13","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}