{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T12:09:01Z","timestamp":1784722141620,"version":"3.55.0"},"reference-count":52,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    Whole-body cross-sectional imaging has largely replaced skeletal survey as the standard for evaluating hematologic malignancies and bone marrow disorders, but the practical choice between whole-body low-dose CT (WBCT) and whole-body MRI (WBMRI) remains incompletely resolved. This clinical review provides a practical, scenario-based comparison of WBCT and WBMRI across diagnosis, staging, treatment response, and surveillance. We emphasize real-world practical considerations, including scanner access, expertise, patient tolerance, radiation considerations, and cost. In multiple myeloma, with available comparative evidence, we include a focused research synthesis of 3 studies (152 patients) demonstrating high pooled CT-MRI concordance of 0.895 (95% CI: 0.834-0.935) with no detectable heterogeneity (\n                    <jats:italic toggle=\"yes\">I<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    =0%), supporting either modality as a reasonable first-line depending on the clinical question. Across all included disease categories, the broader pooled concordance estimate was 0.797 (95% CI: 0.667-0.885) with substantial heterogeneity reflecting variability in clinical context, reference standard, and protocol. WBMRI dominates in non-neoplastic marrow disorders where marrow characterization is essential. In lymphoma, FDG-PET\/CT remains the standard for adult disease, with WBMRI most indicated in pediatrics and adolescents. Emerging CT techniques, including dual-energy CT with virtual noncalcium images and photon-counting detector CT, are extending CT into the marrow imaging space and narrowing the historical gap with MRI. Modality selection should be guided by the specific clinical scenario, available resources, and patient factors rather than by global judgments of modality superiority.\n                  <\/jats:p>","DOI":"10.1097\/rct.0000000000001918","type":"journal-article","created":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T12:00:11Z","timestamp":1784721611000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Complementary Role of Whole-Body MRI and CT in Hematologic Malignancies and Bone Marrow Disorders"],"prefix":"10.1097","author":[{"given":"Elena","family":"Ghotbi","sequence":"first","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Frick","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joselle","family":"Cook","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Hematology, Mayo Clinic, Rochester, MN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8005-4823","authenticated-orcid":false,"given":"Francis","family":"Baffour","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7,22]]},"reference":[{"key":"R1-20260722","doi-asserted-by":"crossref","first-page":"e206","DOI":"10.1016\/S1470-2045(17)30189-4","article-title":"Role of (18)F-FDG PET\/ CT in the diagnosis and management of multiple myeloma and other plasma cell disorders: a consensus statement by the International Myeloma Working Group","volume":"18","author":"Cavo","year":"2017","journal-title":"Lancet Oncol"},{"key":"R2-20260722","doi-asserted-by":"crossref","first-page":"e302","DOI":"10.1016\/S1470-2045(19)30309-2","article-title":"International Myeloma Working Group consensus recommendations on imaging in monoclonal plasma cell disorders","volume":"20","author":"Hillengass","year":"2019","journal-title":"Lancet Oncol"},{"key":"R3-20260722","doi-asserted-by":"crossref","first-page":"3059","DOI":"10.1200\/JCO.2013.54.8800","article-title":"Recommendations for initial evaluation, staging, and response assessment of Hodgkin and non-Hodgkin lymphoma: the Lugano classification","volume":"32","author":"Cheson","year":"2014","journal-title":"J Clin Oncol"},{"key":"R4-20260722","doi-asserted-by":"crossref","first-page":"3048","DOI":"10.1200\/JCO.2013.53.5229","article-title":"Role of imaging in the staging and response assessment of lymphoma: consensus of the International Conference on Malignant Lymphomas Imaging Working Group","volume":"32","author":"Barrington","year":"2014","journal-title":"J Clin Oncol"},{"key":"R5-20260722","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.2214\/AJR.07.2635","article-title":"Whole-body MRI versus whole-body MDCT for staging of multiple myeloma","volume":"190","author":"Baur-Melnyk","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"R6-20260722","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.2214\/AJR.06.1410","article-title":"Semiquantitative assessment of skeletal response to enzyme replacement therapy for Gaucher\u2019s disease using the bone marrow burden score","volume":"188","author":"Robertson","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"R7-20260722","doi-asserted-by":"crossref","first-page":"102933","DOI":"10.1016\/j.bcmd.2025.102933","article-title":"An analysis of bone marrow burden scores in a retrospective analysis of adult patients with type 1 Gaucher disease","volume":"113-114","author":"Miron","year":"2025","journal-title":"Blood Cells Mol Dis"},{"key":"R8-20260722","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/j.ejrad.2004.04.015","article-title":"Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: an alternative to conventional radiography","volume":"54","author":"Horger","year":"2005","journal-title":"Eur J Radiol"},{"key":"R9-20260722","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s00330-007-0738-3","article-title":"Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma","volume":"18","author":"Kr\u00f6pil","year":"2008","journal-title":"Eur Radiol"},{"key":"R10-20260722","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1038\/s41408-018-0124-1","article-title":"Recommendations for acquisition, interpretation and reporting of whole body low dose CT in patients with multiple myeloma and other plasma cell disorders: a report of the IMWG Bone Working Group","volume":"8","author":"Moulopoulos","year":"2018","journal-title":"Blood Cancer J"},{"key":"R11-20260722","doi-asserted-by":"crossref","first-page":"2322","DOI":"10.1016\/j.ejrad.2013.08.036","article-title":"Diagnostic value of whole-body low-dose computed tomography (WBLDCT) in bone lesions detection in patients with multiple myeloma (MM)","volume":"82","author":"Ippolito","year":"2013","journal-title":"Eur J Radiol"},{"key":"R12-20260722","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s11547-015-0573-6","article-title":"Patient dose evaluation for the whole- body low-dose multidetector CT (WBLDMDCT) skeleton study in multiple myeloma (MM)","volume":"121","author":"Cretti","year":"2016","journal-title":"Radiol Med"},{"key":"R13-20260722","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1148\/radiol.220311","article-title":"Photon-counting detector CT with deep learning noise reduction to detect multiple myeloma","volume":"306","author":"Baffour","year":"2023","journal-title":"Radiology"},{"key":"R14-20260722","doi-asserted-by":"crossref","first-page":"2490","DOI":"10.3892\/ol.2017.5723","article-title":"Whole-body low- dose computed tomography in multiple myeloma staging: superior diagnostic performance in the detection of bone lesions, vertebral compression fractures, rib fractures and extraskeletal findings compared to radiography with similar radiation exposure","volume":"13","author":"Lambert","year":"2017","journal-title":"Oncol Lett"},{"key":"R15-20260722","doi-asserted-by":"crossref","first-page":"e220073","DOI":"10.1148\/rycan.220073","article-title":"Prospective multireader evaluation of photon-counting CT for multiple myeloma screening","volume":"4","author":"Schwartz","year":"2022","journal-title":"Radiol Imaging Cancer"},{"key":"R16-20260722","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1007\/s00256-008-0607-4","article-title":"Accuracy of whole- body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI)","volume":"38","author":"Gleeson","year":"2009","journal-title":"Skeletal Radiol"},{"key":"R17-20260722","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1097\/01.rct.0000237820.41549.c9","article-title":"Efficacy of multidetector row computed tomography of the spine in patients with multiple myeloma: comparison with magnetic resonance imaging and fluorodeoxyglucose-positron emission tomography","volume":"31","author":"Hur","year":"2007","journal-title":"J Comput Assist Tomogr"},{"key":"R18-20260722","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1038\/s41408-025-01327-4","article-title":"Whole body MRI by MY-RADS for imaging response assessment in multiple myeloma","volume":"15","author":"Messiou","year":"2025","journal-title":"Blood Cancer J"},{"key":"R19-20260722","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1111\/bjh.14827","article-title":"Guidelines for the use of imaging in the management of patients with myeloma","volume":"178","author":"Chantry","year":"2017","journal-title":"Br J Haematol"},{"key":"R20-20260722","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1148\/radiol.2019181949","article-title":"Guidelines for acquisition, interpretation, and reporting of whole-body MRI in myeloma: myeloma response assessment and diagnosis system (MY-RADS)","volume":"291","author":"Messiou","year":"2019","journal-title":"Radiology"},{"key":"R21-20260722","doi-asserted-by":"crossref","first-page":"e599","DOI":"10.1038\/bcj.2017.78","article-title":"Whole-body computed tomography versus conventional skeletal survey in patients with multiple myeloma: a study of the International Myeloma Working Group","volume":"7","author":"Hillengass","year":"2017","journal-title":"Blood Cancer J"},{"key":"R22-20260722","doi-asserted-by":"crossref","first-page":"e538","DOI":"10.1016\/S1470-2045(14)70442-5","article-title":"International Myeloma Working Group updated criteria for the diagnosis of multiple myeloma","volume":"15","author":"Rajkumar","year":"2014","journal-title":"Lancet Oncol"},{"key":"R23-20260722","doi-asserted-by":"crossref","first-page":"e328","DOI":"10.1016\/S1470-2045(16)30206-6","article-title":"International Myeloma Working Group consensus criteria for response and minimal residual disease assessment in multiple myeloma","volume":"17","author":"Kumar","year":"2016","journal-title":"Lancet Oncol"},{"key":"R24-20260722","doi-asserted-by":"crossref","first-page":"e418","DOI":"10.1200\/EDBK_159009","article-title":"Updated diagnostic criteria and staging system for multiple myeloma","volume":"35","author":"Rajkumar","year":"2016","journal-title":"Am Soc Clin Oncol Educ Book"},{"key":"R25-20260722","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.2214\/ajr.178.6.1781429","article-title":"Multidetector CT of the spine in multiple myeloma: comparison with MR imaging and radiography","volume":"178","author":"Mahnken","year":"2002","journal-title":"AJR Am J Roentgenol"},{"key":"R26-20260722","doi-asserted-by":"crossref","first-page":"e415","DOI":"10.3324\/haematol.2016.146092","article-title":"Baseline bone involvement in multiple myeloma\u2014a prospective comparison of conventional x-ray, low-dose computed tomography, and 18flourodeoxyglucose positron emission tomography in previously untreated patients","volume":"101","author":"Hinge","year":"2016","journal-title":"Haematologica"},{"key":"R27-20260722","doi-asserted-by":"crossref","first-page":"514","DOI":"10.2214\/AJR.18.20989","article-title":"Comparison of whole-body DWI and (18)F-FDG PET\/CT for detecting intramedullary and extramedullary lesions in multiple myeloma","volume":"213","author":"Chen","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"R28-20260722","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/s00256-021-03799-4","article-title":"Whole-body magnetic resonance imaging (WBMRI) versus whole-body computed tomography (WBCT) for myeloma imaging and staging","volume":"51","author":"Treitl","year":"2022","journal-title":"Skeletal Radiol"},{"key":"R29-20260722","doi-asserted-by":"crossref","first-page":"966","DOI":"10.1002\/ajh.25846","article-title":"Role of imaging in multiple myeloma","volume":"95","author":"Baffour","year":"2020","journal-title":"Am J Hematol"},{"key":"R30-20260722","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1016\/j.ejrad.2014.02.008","article-title":"Sensitivity of whole-body CT and MRI versus projection radiography in the detection of osteolyses in patients with monoclonal plasma cell disease","volume":"83","author":"Wolf","year":"2014","journal-title":"Eur J Radiol"},{"key":"R31-20260722","doi-asserted-by":"crossref","first-page":"602","DOI":"10.2214\/AJR.21.26381","article-title":"Comparative performance of whole-body MRI and FDG PET\/CT in evaluation of multiple myeloma treatment response: systematic review and meta-analysis","volume":"218","author":"Rama","year":"2022","journal-title":"AJR Am J Roentgenol"},{"key":"R32-20260722","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.critrevonc.2018.02.012","article-title":"Comparison of whole body magnetic resonance imaging (WBMRI) to whole body computed tomography (WBCT) or (18)F-fluorodeoxyglucose positron emission tomography\/CT ((18)F-FDG PET\/CT) in patients with myeloma: systematic review of diagnostic performance","volume":"124","author":"Gariani","year":"2018","journal-title":"Crit Rev Oncol Hematol"},{"key":"R33-20260722","first-page":"101597","article-title":"Imaging in plasma cell disorders-consensus recommendations of the Asian Myeloma Network Bone Imaging workgroup","volume":"59","author":"Nagarajan","year":"2025","journal-title":"Lancet Reg Health West Pac"},{"key":"R34-20260722","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1111\/bjh.14545","article-title":"Diagnostic value of whole-body ultra-low dose computed tomography in comparison with spinal magnetic resonance imaging in the assessment of disease in multiple myeloma","volume":"177","author":"Ippolito","year":"2017","journal-title":"Br J Haematol"},{"key":"R35-20260722","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1007\/s00247-005-1459-x","article-title":"Whole-body MRI of paediatric malignant tumours: comparison with conventional oncological imaging methods","volume":"35","author":"Goo","year":"2005","journal-title":"Pediatr Radiol"},{"key":"R36-20260722","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1097\/RLI.0b013e3181afbb36","article-title":"Whole-body MRI, including diffusion-weighted imaging, for the initial staging of malignant lymphoma: comparison to computed tomography","volume":"44","author":"Kwee","year":"2009","journal-title":"Invest Radiol"},{"key":"R37-20260722","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1002\/jmri.24356","article-title":"Whole-body MRI, including diffusion-weighted imaging, for staging lymphoma: comparison with CT in a prospective multicenter study","volume":"40","author":"Kwee","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"R38-20260722","doi-asserted-by":"crossref","first-page":"742","DOI":"10.2214\/AJR.20.23204","article-title":"Whole-Body Low-Dose CT in Multiple Myeloma: Diagnostic Value of Appendicular Medullary Patterns of Attenuation","volume":"216","author":"Koutoulidis","year":"2021","journal-title":"AJR Am J Roentgenol"},{"key":"R39-20260722","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1148\/radiol.2017170281","article-title":"Multiple myeloma and dual-energy CT: diagnostic accuracy of virtual noncalcium technique for detection of bone marrow infiltration of the spine and pelvis","volume":"286","author":"Kosmala","year":"2018","journal-title":"Radiology"},{"key":"R40-20260722","doi-asserted-by":"crossref","first-page":"6346","DOI":"10.1002\/mp.15934","article-title":"Deep learning- based virtual noncalcium imaging in multiple myeloma using dual-energy CT","volume":"49","author":"Gong","year":"2022","journal-title":"Med Phys"},{"key":"R41-20260722","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1148\/radiol.212579","article-title":"First clinical photon-counting detector CT system: technical evaluation","volume":"303","author":"Rajendran","year":"2022","journal-title":"Radiology"},{"key":"R42-20260722","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1159\/000531461","article-title":"Photon counting detector computed tomography: a new frontier of myeloma bone disease evaluation","volume":"146","author":"Cook","year":"2023","journal-title":"Acta Haematol"},{"key":"R43-20260722","doi-asserted-by":"crossref","first-page":"1402","DOI":"10.1002\/mrm.27117","article-title":"Whole-body MRI for metastatic cancer detection using T(2)-weighted imaging with fat and fluid suppression","volume":"80","author":"Wang","year":"2018","journal-title":"Magn Reson Med"},{"key":"R44-20260722","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1002\/jmri.22282","article-title":"T(2)- weighted 3D fast spin echo imaging with water-fat separation in a single acquisition","volume":"32","author":"Madhuranthakam","year":"2010","journal-title":"J Magn Reson Imaging"},{"key":"R45-20260722","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1148\/radiol.2016152842","article-title":"MR neurography of brachial plexus at 3.0 T with robust fat and blood suppression","volume":"283","author":"Wang","year":"2017","journal-title":"Radiology"},{"issue":"suppl 2","key":"R46-20260722","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1007\/s00247-006-0191-5","article-title":"Cancer risks following diagnostic and therapeutic radiation exposure in children","volume":"36","author":"Kleinerman","year":"2006","journal-title":"Pediatr Radiol"},{"key":"R47-20260722","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1056\/NEJMoa2502098","article-title":"Medical imaging and pediatric and adolescent hematologic cancer risk","volume":"393","author":"Smith-Bindman","year":"2025","journal-title":"N Engl J Med"},{"key":"R48-20260722","doi-asserted-by":"crossref","first-page":"20230106","DOI":"10.1259\/bjr.20230106","article-title":"Cumulative radiation exposure from radiological imaging in patients with Hodgkin and diffuse large B-cell lymphoma not submitted to radiotherapy","volume":"96","author":"Brambilla","year":"2023","journal-title":"Br J Radiol"},{"key":"R49-20260722","doi-asserted-by":"crossref","first-page":"8925","DOI":"10.1007\/s00330-021-08026-1","article-title":"Whole-body MRI versus an [(18)F]FDG-PET\/CT-based reference standard for early response assessment and restaging of paediatric Hodgkin\u2019s lymphoma: a prospective multicentre study","volume":"31","author":"Spijkers","year":"2021","journal-title":"Eur Radiol"},{"key":"R50-20260722","doi-asserted-by":"crossref","first-page":"1494","DOI":"10.1007\/s00330-020-07182-0","article-title":"Whole-body MRI versus an FDG-PET\/CT-based reference standard for staging of paediatric Hodgkin lymphoma: a prospective multicentre study","volume":"31","author":"Spijkers","year":"2021","journal-title":"Eur Radiol"},{"key":"R51-20260722","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1080\/16078454.2020.1781500","article-title":"The diagnostic and prognostic value of MRI in central nervous system involvement of acute myeloid leukemia: a retrospective cohort of 84 patients","volume":"25","author":"Shen","year":"2020","journal-title":"Hematology"},{"key":"R52-20260722","first-page":"3843","article-title":"Fat fraction quantification in TSE based 2-point Dixon acquisition: application to whole-body MRI","volume":"29","author":"Lin","year":"2021","journal-title":"Proc Intl Soc Mag Reson Med"}],"container-title":["Journal of Computer Assisted Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001918","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T12:00:18Z","timestamp":1784721618000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RCT.0000000000001918"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,22]]},"references-count":52,"URL":"https:\/\/doi.org\/10.1097\/rct.0000000000001918","relation":{},"ISSN":["1532-3145"],"issn-type":[{"value":"1532-3145","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,22]]},"assertion":[{"value":"2026-06-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}