{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T11:26:34Z","timestamp":1778671594760,"version":"3.51.4"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2016,8]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>\n                      The aims of this preliminary study were to determine the number of axonal bundles (fascicles) in the median nerve,\n                      <jats:sup>1<\/jats:sup>\n                      using a high-resolution, proton density (PD)\u2013turbo spin echo (TSE) fat suppression sequence, and to determine normative T\n                      <jats:sub>2<\/jats:sub>\n                      values, measured by triple-echo steady state, of the median nerve in healthy volunteers and in patients with idiopathic carpal tunnel syndrome (CTS), at 7 T.\n                      <jats:sup>2<\/jats:sup>\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>\n                      This prospective study was approved by the local ethics committee and conducted between March 2014 and January 2015. All study participants gave written informed consent. Six healthy volunteers (30 \u00b1 12 years) and 5 patients with CTS (44 \u00b1 16 years) were included. Measurements were performed on both wrists in all volunteers and on the affected wrist in patients (3 right, 2 left). Based on 5-point scales, 2 readers assessed image quality (1, very poor; 5, very good) and the presence of artifacts that might have a possible influence on fascicle determination (1, severe artifacts; 5, no artifacts) and counted the number of fascicles independently on the PD-TSE sequences. Furthermore, T\n                      <jats:sub>2<\/jats:sub>\n                      values by region of interest analysis were assessed. Student\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      tests, a hierarchic linear model, and intraclass correlation coefficients (ICCs) were used for statistical analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Proton density-TSE image quality and artifacts revealed a median of 5 in healthy volunteers and 4 in patients with CTS for both readers. Fascicle count of the median nerve ranged from 13 to 23 in all subjects, with an ICC of 0.87 (95% confidence interval [CI], 0.67\u20130.95). T\n                      <jats:sub>2<\/jats:sub>\n                      values were significantly higher (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.023) in patients (24.27 \u00b1 0.97 milliseconds [95% CI, 22.19\u201326.38]) compared with healthy volunteers (21.01 \u00b1 0.65 milliseconds [95% CI, 19.61\u201322.41]). The ICC for all T\n                      <jats:sub>2<\/jats:sub>\n                      values was 0.97 (95% CI, 0.96\u20130.98).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      This study shows the possibility of fascicle determination of the median nerve in healthy volunteers and patients with CTS (although probably less accurately) with high-resolution 7 T magnetic resonance imaging, as well as significantly higher T\n                      <jats:sub>2<\/jats:sub>\n                      values in patients with CTS, which seems to be associated with pathophysiological nerve changes.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rli.0000000000000265","type":"journal-article","created":{"date-parts":[[2016,3,4]],"date-time":"2016-03-04T19:17:41Z","timestamp":1457119061000},"page":"529-535","source":"Crossref","is-referenced-by-count":29,"title":["High-Resolution Axonal Bundle (Fascicle) Assessment and Triple-Echo Steady-State T2 Mapping of the Median Nerve at 7 T"],"prefix":"10.1097","volume":"51","author":[{"given":"Georg","family":"Riegler","sequence":"first","affiliation":[{"name":"From the *MR Centre of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; \u2020Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; and \u2021Department of Neurology, Medical University of Vienna, Vienna, Austria."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregor","family":"Drlicek","sequence":"additional","affiliation":[{"name":"From the *MR Centre of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; \u2020Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; and \u2021Department of Neurology, Medical University of Vienna, Vienna, Austria."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claudia","family":"Kronnerwetter","sequence":"additional","affiliation":[{"name":"From the *MR Centre of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; \u2020Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; and \u2021Department of Neurology, Medical University of Vienna, Vienna, Austria."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rahel","family":"Heule","sequence":"additional","affiliation":[{"name":"From the *MR Centre of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; \u2020Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; and \u2021Department of Neurology, Medical University of Vienna, Vienna, Austria."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Bieri","sequence":"additional","affiliation":[{"name":"From the *MR Centre of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; \u2020Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; and \u2021Department of Neurology, Medical University of Vienna, Vienna, Austria."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerd","family":"Bodner","sequence":"additional","affiliation":[{"name":"From the *MR Centre of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; \u2020Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; and \u2021Department of Neurology, Medical University of Vienna, Vienna, Austria."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Doris","family":"Lieba-Samal","sequence":"additional","affiliation":[{"name":"From the *MR Centre of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; \u2020Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; and \u2021Department of Neurology, Medical University of Vienna, Vienna, Austria."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siegfried","family":"Trattnig","sequence":"additional","affiliation":[{"name":"From the *MR Centre of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; \u2020Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; and \u2021Department of Neurology, Medical University of Vienna, Vienna, Austria."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20231030","doi-asserted-by":"crossref","first-page":"2151","DOI":"10.1016\/S0140-6736(04)16508-2","article-title":"Peripheral neuropathy","volume":"363","year":"2004","journal-title":"Lancet"},{"issue":"4","key":"bib2-20231030","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1136\/jnnp.62.4.310","article-title":"Epidemiology of peripheral neuropathy","volume":"62","year":"1997","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"bib3-20231030","first-page":"809568","article-title":"MR neurography: advances","volume":"2013","year":"2013","journal-title":"Radiol Res Pract"},{"key":"bib4-20231030","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1002\/jmri.23883","article-title":"12-channel receive array with a volume transmit coil for hand\/wrist imaging at 7 T","volume":"38","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"bib5-20231030","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1002\/jmri.20345","article-title":"Microneurography of human median nerve","volume":"21","year":"2005","journal-title":"J Magn Reson Imaging"},{"key":"bib6-20231030","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1177\/0888439004267074","article-title":"High-resolution magnetic resonance imaging of the human median nerve","volume":"18","year":"2004","journal-title":"Neurorehabil Neural Repair"},{"key":"bib7-20231030","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1002\/jmri.22072","article-title":"MRI of the wrist at 7 tesla using an eight-channel array coil combined with parallel imaging: preliminary results","volume":"31","year":"2010","journal-title":"J Magn Reson Imaging"},{"key":"bib8-20231030","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1007\/s00256-002-0506-z","article-title":"In vivo high-resolution MR imaging of the carpal tunnel at 8.0 tesla","volume":"31","year":"2002","journal-title":"Skeletal Radiol"},{"key":"bib9-20231030","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.2214\/ajr.167.5.8911187","article-title":"Correlative MR-anatomic study of the median nerve","volume":"167","year":"1996","journal-title":"AJR Am J Roentgenol"},{"key":"bib10-20231030","doi-asserted-by":"crossref","first-page":"217","DOI":"10.4103\/0971-3026.137025","article-title":"Peripheral nerve injury grading simplified on MR neurography: as referenced to Seddon and Sunderland classifications","volume":"24","year":"2014","journal-title":"Indian J Radiol Imaging"},{"key":"bib11-20231030","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1002\/mus.880130903","article-title":"The anatomy and physiology of nerve injury","volume":"13","year":"1990","journal-title":"Muscle Nerve"},{"key":"bib12-20231030","doi-asserted-by":"crossref","first-page":"1941","DOI":"10.1016\/j.bjps.2009.12.010","article-title":"Modern surgical management of peripheral nerve gap","volume":"63","year":"2010","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"bib13-20231030","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1002\/mus.10454","article-title":"Peripheral nerve fascicles: anatomy and clinical relevance","volume":"28","year":"2003","journal-title":"Muscle Nerve"},{"key":"bib14-20231030","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1097\/RLI.0000000000000156","article-title":"Diffusion tensor imaging adds diagnostic accuracy in magnetic resonance neurography","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib15-20231030","doi-asserted-by":"crossref","first-page":"e775","DOI":"10.1016\/j.ejrad.2012.03.017","article-title":"MR neurography of the median nerve at 3.0 T: optimization of diffusion tensor imaging and fiber tractography","volume":"81","year":"2012","journal-title":"Eur J Radiol"},{"key":"bib16-20231030","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1002\/mus.22240","article-title":"Magnetic resonance imaging of peripheral nerves: differences in magnetization transfer","volume":"45","year":"2012","journal-title":"Muscle Nerve"},{"key":"bib17-20231030","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1002\/jmri.21738","article-title":"NMR properties of human median nerve at 3 T: proton density, T1, T2, and magnetization transfer","volume":"29","year":"2009","journal-title":"J Magn Reson Imaging"},{"key":"bib18-20231030","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1002\/mus.20826","article-title":"Magnetic resonance imaging and T2 relaxometry of human median nerve at 7 Tesla","volume":"36","year":"2007","journal-title":"Muscle Nerve"},{"key":"bib19-20231030","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1002\/mrm.24659","article-title":"Triple echo steady-state (TESS) relaxometry","volume":"71","year":"2014","journal-title":"Magn Reson Med"},{"key":"bib20-20231030","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1002\/mrm.22807","article-title":"Quantitative mapping of T2 using partial spoiling","volume":"66","year":"2011","journal-title":"Magn Reson Med"},{"key":"bib21-20231030","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1002\/mrm.22036","article-title":"Rapid estimation of cartilage T2 based on double echo at steady state (DESS) with 3 Tesla","volume":"62","year":"2009","journal-title":"Magn Reson Med"},{"key":"bib22-20231030","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/RLI.0000000000000015","article-title":"Ultrahigh-resolution imaging of the human brain with phase-cycled balanced steady-state free precession at 7 T","volume":"49","year":"2014","journal-title":"Invest Radiol"},{"key":"bib23-20231030","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1002\/mrm.24748","article-title":"Rapid estimation of cartilage T with reduced T sensitivity using double echo steady state imaging","volume":"71","year":"2014","journal-title":"Magn Reson Med"},{"key":"bib24-20231030","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/S0030-5898(20)30335-7","article-title":"Carpal tunnel syndrome. A scientific basis for clinical care","volume":"19","year":"1988","journal-title":"Orthop Clin North Am"},{"key":"bib25-20231030","doi-asserted-by":"crossref","first-page":"585","DOI":"10.2214\/AJR.10.4817","article-title":"Nerve entrapment syndromes of the elbow, forearm, and wrist","volume":"195","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"bib26-20231030","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.1212\/WNL.58.11.1589","article-title":"Practice parameter: electrodiagnostic studies in carpal tunnel syndrome. Report of the American Association of Electrodiagnostic Medicine, American Academy of Neurology, and the American Academy of Physical Medicine and Rehabilitation","volume":"58","year":"2002","journal-title":"Neurology"},{"key":"bib27-20231030","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.2105\/AJPH.88.10.1447","article-title":"Consensus criteria for the classification of carpal tunnel syndrome in epidemiologic studies","volume":"88","year":"1998","journal-title":"Am J Public Health"},{"key":"bib28-20231030","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","year":"1977","journal-title":"Biometrics"},{"key":"bib29-20231030","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.jhsa.2009.12.009","article-title":"Treatment of acute peripheral nerve injuries: current concepts","volume":"35","year":"2010","journal-title":"J Hand Surg Am"},{"key":"bib30-20231030","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1055\/s-0029-1202942","article-title":"In vivo 7.0-tesla magnetic resonance imaging of the wrist and hand: technical aspects and applications","volume":"13","year":"2009","journal-title":"Semin Musculoskelet Radiol"},{"key":"bib31-20231030","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/0022-510X(84)90037-6","article-title":"Long-term remyelination fails to reconstitute normal thickness of central myelin sheaths","volume":"64","year":"1984","journal-title":"J Neurol Sci"},{"key":"bib32-20231030","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1111\/j.1365-2990.1986.tb00159.x","article-title":"Chronic human nerve compression\u2014a histological assessment","volume":"12","year":"1986","journal-title":"Neuropathol Appl Neurobiol"},{"key":"bib33-20231030","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/j.jhsa.2010.01.007","article-title":"Compressive neuropathies of the upper extremity: update on pathophysiology, classification, and electrodiagnostic findings","volume":"35","year":"2010","journal-title":"J Hand Surg Am"},{"key":"bib34-20231030","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1002\/mrm.10411","article-title":"Is multicomponent T2 a good measure of myelin content in peripheral nerve?","volume":"49","year":"2003","journal-title":"Magn Reson Med"},{"key":"bib35-20231030","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1002\/mrm.1910350212","article-title":"Multiexponential T2 relaxation in degenerating peripheral nerve","volume":"35","year":"1996","journal-title":"Magn Reson Med"},{"key":"bib36-20231030","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1016\/S0730-725X(98)00151-9","article-title":"Multicomponent water proton transverse relaxation and T2-discriminated water diffusion in myelinated and nonmyelinated nerve","volume":"16","year":"1998","journal-title":"Magn Reson Imaging"},{"key":"bib37-20231030","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1002\/nbm.3152","article-title":"Triple-echo steady-state T2 relaxometry of the human brain at high to ultra-high fields","volume":"27","year":"2014","journal-title":"NMR Biomed"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004424-201608000-00008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T16:16:22Z","timestamp":1698682582000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004424-201608000-00008"}},"subtitle":["Preliminary Experience"],"short-title":[],"issued":{"date-parts":[[2016,8]]},"references-count":37,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000265","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.730180027.793566469","asserted-by":"object"}]},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2016,8]]}}}