{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T12:29:33Z","timestamp":1763036973624},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>Time-of-arrival (TOA) maps can be derived from high-resolution 4-dimensional (4D) contrast-enhanced magnetic resonance angiography (MRA) data sets to provide a quantitative description of contrast material arrival time in each voxel. This information can further be processed to create a compressed time evolution curve that virtually shortens the contrast bolus (virtual bolus [VB]). The purpose of this project was to determine whether TOA-enhanced 4D MRA and\/or VB imaging improve the display of contrast kinetics in patients with vascular disease.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>High-resolution whole-brain contrast-enhanced 4D MRA examinations with 1.2-second temporal reconstruction were acquired by using radial acquisition and highly constrained projection reconstruction (radial 4D contrast-enhanced HYPRFlow, abbreviated as HFMRA in this article) in 10 patients (8 patients with arteriovenous malformations [AVM], 1 patient with an arteriovenous fistula, and 1 patient with a high-grade intracranial stenosis). The TOA for each voxel was defined as the time point when the signal intensity reached 20% of its maximum. In the first method, TOA maps were generated, color-encoded, and then multiplied with the time-resolved contrast-enhanced MRA images at each time frame to form new 4D MRA images (TOA-enhanced HFMRA), which contains the contrast arrival times with defined color encoding. In the second method, each time frame was weighted by a Gaussian distribution in the time domain to form a virtual 4D bolus map. This 4D bolus map was then color-coded and multiplied with the HFMRA images to form a digital subtraction angiography (DSA)\u2013like VB, where at each time frame, only vessels with certain TOA values within the defined bolus length appear. HFMRA, TOA maps, and VB images were scored qualitatively with regard to delineation of arteries, veins, and nidus, as well as artifacts. Furthermore, diagnostic confidence and arteriovenous overlap were evaluated and compared between techniques. A comparison with DSA was performed where DSA served as the reference standard in terms of number of arterial feeders, draining veins, and Spetzler-Martin score of AVMs. In addition, TOA maps were evaluated quantitatively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Overall, diagnostic confidence score of TOA was significantly higher compared with that of HFMRA (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.03). Virtual bolus showed significantly higher scores for overall diagnostic confidence (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.02) and reduced arteriovenous overlap (0.01) compared with HFMRA. Furthermore, VB-reduced arteriovenous overlap scores were significantly higher compared with TOA (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.04). Agreement regarding AVM draining veins was lower between DSA and HFMRA (\u03ba = 0.3) compared with TOA and VB (\u03ba = 0.56). Agreement regarding Spetzler-Martin score was lower between DSA and HFMRA (\u03ba = 0.56) compared with TOA and VB (\u03ba = 0.74).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>TOA-enhanced HFMRA provides serial images and time of arrival maps in one inclusive display. In this study, TOA mapping combined with Virtual Bolus imaging improved diagnostic confidence in AVM patients and facilitated arteriovenous separation. The VB method further reduced overlap of arterial and venous structures.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rli.0000000000000288","type":"journal-article","created":{"date-parts":[[2016,5,12]],"date-time":"2016-05-12T11:24:41Z","timestamp":1463052281000},"page":"706-713","source":"Crossref","is-referenced-by-count":9,"title":["Time-of-Arrival Parametric Maps and Virtual Bolus Images Derived From Contrast-Enhanced Time-Resolved Radial Magnetic Resonance Angiography Improve the Display of Brain Arteriovenous Malformation Vascular Anatomy"],"prefix":"10.1097","volume":"51","author":[{"given":"Tilman","family":"Schubert","sequence":"first","affiliation":[{"name":"From the *Department of Radiology, University of Wisconsin-Madison, Madison, WI; \u2020Clinic for Radiology and Nuclear Medicine, Basel University Hospital, Basel, Switzerland; and \u2021Department of Medical Physics, University of Wisconsin-Madison, Madison, WI."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yijing","family":"Wu","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University of Wisconsin-Madison, Madison, WI; \u2020Clinic for Radiology and Nuclear Medicine, Basel University Hospital, Basel, Switzerland; and \u2021Department of Medical Physics, University of Wisconsin-Madison, Madison, WI."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kevin M.","family":"Johnson","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University of Wisconsin-Madison, Madison, WI; \u2020Clinic for Radiology and Nuclear Medicine, Basel University Hospital, Basel, Switzerland; and \u2021Department of Medical Physics, University of Wisconsin-Madison, Madison, WI."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Wieben","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University of Wisconsin-Madison, Madison, WI; \u2020Clinic for Radiology and Nuclear Medicine, Basel University Hospital, Basel, Switzerland; and \u2021Department of Medical Physics, University of Wisconsin-Madison, Madison, WI."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jane","family":"Maksimovic","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University of Wisconsin-Madison, Madison, WI; \u2020Clinic for Radiology and Nuclear Medicine, Basel University Hospital, Basel, Switzerland; and \u2021Department of Medical Physics, University of Wisconsin-Madison, Madison, WI."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"Mistretta","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University of Wisconsin-Madison, Madison, WI; \u2020Clinic for Radiology and Nuclear Medicine, Basel University Hospital, Basel, Switzerland; and \u2021Department of Medical Physics, University of Wisconsin-Madison, Madison, WI."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Turski","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University of Wisconsin-Madison, Madison, WI; \u2020Clinic for Radiology and Nuclear Medicine, Basel University Hospital, Basel, Switzerland; and \u2021Department of Medical Physics, University of Wisconsin-Madison, Madison, WI."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20230926","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.3174\/ajnr.A2921","article-title":"Noninvasive evaluation of cerebral arteriovenous malformations by 4D-MRA for preoperative planning and postoperative follow-up in 56 patients: comparison with DSA and intraoperative findings","volume":"33","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib2-20230926","doi-asserted-by":"crossref","first-page":"2749","DOI":"10.1161\/STROKEAHA.108.546663","article-title":"4D radial acquisition contrast-enhanced MR angiography and intracranial arteriovenous malformations: quickly approaching digital subtraction angiography","volume":"40","year":"2009","journal-title":"Stroke"},{"key":"bib3-20230926","first-page":"1525","article-title":"Three-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: a preliminary study","volume":"26","year":"2005","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib4-20230926","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1148\/radiol.2453061684","article-title":"Cerebral arteriovenous malformation: Spetzler-Martin classification at subsecond-temporal-resolution four-dimensional MR angiography compared with that at DSA","volume":"246","year":"2008","journal-title":"Radiology"},{"key":"bib5-20230926","doi-asserted-by":"crossref","first-page":"e117","DOI":"10.1016\/j.ejrad.2009.04.063","article-title":"The role of time-resolved 3D contrast-enhanced MR angiography in the assessment and grading of cerebral arteriovenous malformations","volume":"74","year":"2010","journal-title":"Eur J Radiol"},{"key":"bib6-20230926","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1002\/jmri.21483","article-title":"Three-dimensional dynamic time-resolved contrast-enhanced MRA using parallel imaging and a variable rate k-space sampling strategy in intracranial arteriovenous malformations","volume":"29","year":"2009","journal-title":"J Magn Reson Imaging"},{"key":"bib7-20230926","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1148\/radiol.2463070293","article-title":"Intracranial arteriovenous malformation: time-resolved contrast-enhanced MR angiography with combination of parallel imaging, keyhole acquisition, and k-space sampling techniques at 1.5 T","volume":"246","year":"2008","journal-title":"Radiology"},{"key":"bib8-20230926","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1097\/RLI.0b013e3181c7bcfe","article-title":"Cerebral arteriovenous malformations at 3.0 T: intraindividual comparative study of 4D-MRA in combination with selective arterial spin labeling and digital subtraction angiography","volume":"45","year":"2010","journal-title":"Invest Radiol"},{"key":"bib9-20230926","doi-asserted-by":"crossref","first-page":"E47","DOI":"10.3174\/ajnr.A2048","article-title":"Fast whole-brain 4D contrast-enhanced MR angiography with velocity encoding using undersampled radial acquisition and highly constrained projection reconstruction: image-quality assessment in volunteer subjects","volume":"32","year":"2011","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib10-20230926","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1002\/jmri.22035","article-title":"PC HYPR flow: a technique for rapid imaging of contrast dynamics","volume":"31","year":"2010","journal-title":"J Magn Reson Imaging"},{"issue":"6","key":"bib11-20230926","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.3174\/ajnr.A4245","article-title":"Fast contrast-enhanced 4D MRA and 4D flow MRI using constrained reconstruction (HYPRFlow): potential applications for brain arteriovenous malformations","volume":"36","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib13-20230926","doi-asserted-by":"crossref","first-page":"3230","DOI":"10.1007\/s00330-015-3745-9","article-title":"Interest of HYPR flow dynamic MRA for characterization of cerebral arteriovenous malformations: comparison with TRICKS MRA and catheter DSA","volume":"25","year":"2015","journal-title":"Eur Radiol"},{"key":"bib14-20230926","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1007\/s00330-005-0011-6","article-title":"Three-dimensional dynamic magnetic resonance angiography for the evaluation of radiosurgically treated cerebral arteriovenous malformations","volume":"16","year":"2006","journal-title":"Eur Radiol"},{"key":"bib15-20230926","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1002\/mrm.1910360304","article-title":"Time-resolved contrast-enhanced 3D MR angiography","volume":"36","year":"1996","journal-title":"Magn Reson Med"},{"key":"bib16-20230926","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1097\/01.rli.0000192416.19801.ca","article-title":"Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 tesla: initial results","volume":"41","year":"2006","journal-title":"Invest Radiol"},{"key":"bib17-20230926","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1148\/radiol.2532082322","article-title":"Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography","volume":"253","year":"2009","journal-title":"Radiology"},{"key":"bib18-20230926","doi-asserted-by":"crossref","first-page":"46","DOI":"10.3174\/ajnr.A3204","article-title":"Classification of cerebral arteriovenous malformations and intranidal flow patterns by color-encoded 4D-hybrid-MRA","volume":"34","year":"2013","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib19-20230926","doi-asserted-by":"crossref","first-page":"919","DOI":"10.3174\/ajnr.A2020","article-title":"Parametric color coding of digital subtraction angiography","volume":"31","year":"2010","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib20-20230926","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1002\/mrm.10212","article-title":"Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory","volume":"48","year":"2002","journal-title":"Magn Reson Med"},{"key":"bib21-20230926","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1002\/(SICI)1522-2594(200001)43:1<91::AID-MRM11>3.0.CO;2-4","article-title":"Undersampled projection reconstruction applied to MR angiography","volume":"43","year":"2000","journal-title":"Magn Reson Med"},{"key":"bib22-20230926","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1002\/mrm.21505","article-title":"Improved waveform fidelity using local HYPR reconstruction (HYPR LR)","volume":"59","year":"2008","journal-title":"Magn Reson Med"},{"key":"bib23-20230926","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1002\/mrm.22202","article-title":"Improved SNR in phase contrast velocimetry with five-point balanced flow encoding","volume":"63","year":"2010","journal-title":"Magn Reson Med"},{"key":"bib24-20230926","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1002\/mrm.21364","article-title":"4D radial contrast-enhanced MR angiography with sliding subtraction","volume":"58","year":"2007","journal-title":"Magn Reson Med"},{"key":"bib25-20230926","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.1002\/jmri.24466","article-title":"Supra-aortic arteries: three-dimensional time-resolved k-t BLAST contrast-enhanced MRA using a nondedicated body coil at 3 tesla in acute ischemic stroke","volume":"40","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"bib26-20230926","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.3174\/ajnr.A2093","article-title":"Quality-evaluation scheme for cerebral time-resolved 3D contrast-enhanced MR angiography techniques","volume":"31","year":"2010","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib27-20230926","doi-asserted-by":"crossref","first-page":"476","DOI":"10.3171\/jns.1986.65.4.0476","article-title":"A proposed grading system for arteriovenous malformations","volume":"65","year":"1986","journal-title":"J Neurosurg"},{"key":"bib28-20230926","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","year":"1977","journal-title":"Biometrics"},{"key":"bib29-20230926","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/mrm.1910080102","article-title":"MR fluoroscopy: technical feasibility","volume":"8","year":"1988","journal-title":"Magn Reson Med"},{"key":"bib30-20230926","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1002\/jmri.24279","article-title":"Noncontrast dynamic 3D intracranial MR angiography using pseudo-continuous arterial spin labeling (PCASL) and accelerated 3D radial acquisition","volume":"39","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"bib31-20230926","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1148\/radiol.10090908","article-title":"Intravenous contrast medium administration and scan timing at CT: considerations and approaches","volume":"256","year":"2010","journal-title":"Radiology"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004424-201611000-00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T17:48:41Z","timestamp":1695750521000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004424-201611000-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11]]},"references-count":30,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000288","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2016,11]]}}}