{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T20:12:13Z","timestamp":1784664733804,"version":"3.55.0"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2016,10]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>Dual-energy computed tomographic angiography (DE-CTA) has been demonstrated to improve the visualization of the head and neck vessels. The aim of this study was to test the potential of split-filter single-source dual-energy CT to automatically remove bone from the final CTA data set.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods<\/jats:title>\n            <jats:p>Dual-energy CTA was performed in 50 consecutive patients to evaluate the supra-aortic arteries, either to grade carotid artery stenosis or to rule out traumatic dissections. Dual-energy CTA was performed on a 128-slice single-source CT system equipped with a special filter array to separate the 120-kV spectrum into a high- and a low-energy spectrum for DE-based automated bone removal. Image quality of fully automated bone suppression and subsequent manual optimization was evaluated by 2 radiologists on maximum intensity projections using a 4-grade scoring system. The effect of image reconstruction with an iterative metal artifact reduction algorithm on DE postprocessing was tested using a 3-grade scoring system, and the time demand for each postprocessing step was measured.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Two patients were excluded due to insufficient arterial contrast enhancement; in the remaining 48 patients, automated bone removal could be performed successfully. The addition of iterative metal artifact reduction algorithm improved image quality in 58.3% of the cases. After manual optimization, DE-CTA image quality was rated excellent in 7, good in 29, and moderate in 10 patients. Interobserver agreement was high (\u03ba = 0.85). Stenosis grading was not influenced using DE-CTA with bone removal as compared with the original CTA. The time demand for DE image reconstruction was significantly higher than for single-energy reconstruction (42.1 vs 20.9 seconds).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Our results suggest that bone removal in DE-CTA of the head and neck vessels with a single-source CT is feasible and can be performed within acceptable time and moderate user interaction.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rli.0000000000000290","type":"journal-article","created":{"date-parts":[[2016,5,17]],"date-time":"2016-05-17T15:41:07Z","timestamp":1463499667000},"page":"618-623","source":"Crossref","is-referenced-by-count":38,"title":["Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography"],"prefix":"10.1097","volume":"51","author":[{"given":"Nadine","family":"Kaemmerer","sequence":"first","affiliation":[{"name":"From the *Department of Radiology, University Hospital Erlangen-Nuremberg, Erlangen; and \u2020Siemens AG, Healthcare Sector, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Brand","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University Hospital Erlangen-Nuremberg, Erlangen; and \u2020Siemens AG, Healthcare Sector, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Hammon","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University Hospital Erlangen-Nuremberg, Erlangen; and \u2020Siemens AG, Healthcare Sector, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"May","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University Hospital Erlangen-Nuremberg, Erlangen; and \u2020Siemens AG, Healthcare Sector, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang","family":"Wuest","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard","family":"Krauss","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University Hospital Erlangen-Nuremberg, Erlangen; and \u2020Siemens AG, Healthcare Sector, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Uder","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University Hospital Erlangen-Nuremberg, Erlangen; and \u2020Siemens AG, Healthcare Sector, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael M.","family":"Lell","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, University Hospital Erlangen-Nuremberg, Erlangen; and \u2020Siemens AG, Healthcare Sector, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20230926","doi-asserted-by":"crossref","first-page":"875","DOI":"10.3174\/ajnr.A0950","article-title":"High-resolution CT imaging of carotid artery atherosclerotic plaques","volume":"29","year":"2008","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib2-20230926","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1097\/01.rli.0000242835.00032.f5","article-title":"3 T contrast-enhanced magnetic resonance angiography for evaluation of the intracranial arteries: comparison with time-of-flight magnetic resonance angiography and multislice computed tomography angiography","volume":"41","year":"2006","journal-title":"Invest Radiol"},{"key":"bib3-20230926","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1097\/01.rli.0000236992.21065.04","article-title":"Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla: initial results using highly accelerated parallel acquisition","volume":"41","year":"2006","journal-title":"Invest Radiol"},{"key":"bib4-20230926","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1111\/j.1747-4949.2008.00176.x","article-title":"Carotid imaging for secondary stroke prevention in routine practice","volume":"3","year":"2008","journal-title":"Int J Stroke"},{"key":"bib5-20230926","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1227\/01.NEU.0000047895.82857.EB","article-title":"Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: a meta-analysis","volume":"52","year":"2003","journal-title":"Neurosurgery"},{"key":"bib6-20230926","first-page":"1485","article-title":"Multi-section CT angiography for detection of cerebral aneurysms","volume":"25","year":"2004","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib7-20230926","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1016\/j.ejrad.2004.05.002","article-title":"Multi-slice CT angiography of small cerebral aneurysms: is the direction of aneurysm important in diagnosis?","volume":"53","year":"2005","journal-title":"Eur J Radiol"},{"key":"bib8-20230926","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/rg.243035126","article-title":"CT angiography of intracranial aneurysms: a focus on postprocessing","volume":"24","year":"2004","journal-title":"Radiographics"},{"key":"bib9-20230926","first-page":"1187","article-title":"Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography","volume":"23","year":"2002","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib10-20230926","doi-asserted-by":"crossref","first-page":"593","DOI":"10.2214\/AJR.05.2143","article-title":"MDCT angiography for detection and quantification of small intracranial arteries: comparison with conventional catheter angiography","volume":"188","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"bib11-20230926","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1007\/s0330-005-0032-1","article-title":"Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging","volume":"16","year":"2006","journal-title":"Eur Radiol"},{"key":"bib12-20230926","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1148\/radiology.218.3.r01mr30893","article-title":"CT angiography of the circle of Willis and intracranial internal carotid arteries: maximum intensity projection with matched mask bone elimination-feasibility study","volume":"218","year":"2001","journal-title":"Radiology"},{"key":"bib13-20230926","first-page":"1491","article-title":"Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience\u2014rediscovery of matched mask bone elimination?","volume":"24","year":"2003","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib14-20230926","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1007\/s00330-008-0855-7","article-title":"Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients","volume":"18","year":"2008","journal-title":"Eur Radiol"},{"key":"bib15-20230926","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1097\/RLI.0b013e31819e8ad9","article-title":"Carotid computed tomography angiography with automated bone suppression: a comparative study between dual energy and bone subtraction techniques","volume":"44","year":"2009","journal-title":"Invest Radiol"},{"key":"bib16-20230926","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1007\/s00330-005-2919-2","article-title":"First performance evaluation of a dual-source CT (DSCT) system","volume":"16","year":"2006","journal-title":"Eur Radiol"},{"key":"bib17-20230926","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1016\/j.clinimag.2015.07.023","article-title":"Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease","volume":"39","year":"2015","journal-title":"Clin Imaging"},{"key":"bib18-20230926","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1097\/RLI.0000000000000172","article-title":"Evolution in computed tomography: the battle for speed and dose","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib19-20230926","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1007\/s10554-014-0574-x","article-title":"Analysis of coronary arterial calcification components with coronary CT angiography using single-source dual-energy CT with fast tube voltage switching","volume":"31","year":"2015","journal-title":"Int J Cardiovasc Imaging"},{"key":"bib20-20230926","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.jcct.2014.08.005","article-title":"Feasibility of coronary artery calcium scoring on virtual unenhanced images derived from single-source fast kVp-switching dual-energy coronary CT angiography","volume":"8","year":"2014","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"bib21-20230926","doi-asserted-by":"crossref","first-page":"4679","DOI":"10.1088\/0031-9155\/52\/15\/020","article-title":"K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors","volume":"52","year":"2007","journal-title":"Phys Med Biol"},{"key":"bib22-20230926","article-title":"Initial results of a single-source dual-energy computed tomography technique using a split-filter: assessment of image quality, radiation dose, and accuracy of dual-energy applications in an in vitro and in vivo study","year":"2016","journal-title":"Invest Radiol"},{"key":"bib23-20230926","doi-asserted-by":"crossref","first-page":"856","DOI":"10.3171\/2014.9.JNS14811","article-title":"Plaque morphology (the PLAC Scale) on CT angiography: predicting long-term anatomical success of primary carotid stenting","volume":"123","year":"2015","journal-title":"J Neurosurg"},{"key":"bib24-20230926","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s12928-012-0140-1","article-title":"Coronary CT angiography and high-risk plaque morphology","volume":"28","year":"2013","journal-title":"Cardiovasc Interv Ther"},{"key":"bib25-20230926","first-page":"55","article-title":"Bone-subtraction CT angiography for the evaluation of intracranial aneurysms","volume":"27","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib26-20230926","doi-asserted-by":"crossref","first-page":"e120","DOI":"10.1016\/j.ejrad.2010.08.028","article-title":"Dual energy CTA of the carotid bifurcation: advantage of plaque subtraction for assessment of grade of the stenosis and morphology","volume":"80","year":"2011","journal-title":"Eur J Radiol"},{"key":"bib27-20230926","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1097\/RLI.0b013e31818c3d6b","article-title":"Cranial computed tomography angiography with automated bone subtraction: a feasibility study","volume":"44","year":"2009","journal-title":"Invest Radiol"},{"key":"bib28-20230926","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1007\/s00330-008-1213-5","article-title":"Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography","volume":"19","year":"2009","journal-title":"Eur Radiol"},{"key":"bib29-20230926","first-page":"495","article-title":"Angiographic correlation of CT calcification in the carotid siphon","volume":"20","year":"1999","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib30-20230926","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1016\/j.ejrad.2009.09.022","article-title":"Dual energy CTA of the supraaortic arteries: technical improvements with a novel dual source CT system","volume":"76","year":"2010","journal-title":"Eur J Radiol"},{"key":"bib31-20230926","doi-asserted-by":"crossref","first-page":"4349","DOI":"10.1118\/1.4922654","article-title":"Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: a simulation study","volume":"42","year":"2015","journal-title":"Med Phys"},{"key":"bib32-20230926","doi-asserted-by":"crossref","first-page":"1988","DOI":"10.3174\/ajnr.A4386","article-title":"Improved image quality in head and neck CT using a 3D iterative approach to reduce metal artifact","volume":"36","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib33-20230926","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1097\/RLI.0000000000000191","article-title":"Metal artifact reduction in pelvic computed tomography with hip prostheses: comparison of virtual monoenergetic extrapolations from dual-energy computed tomography and an iterative metal artifact reduction algorithm in a phantom study","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib34-20230926","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1097\/RLI.0000000000000083","article-title":"Single-source dual-energy computed tomography: use of monoenergetic extrapolation for a reduction of metal artifacts","volume":"49","year":"2014","journal-title":"Invest Radiol"},{"key":"bib35-20230926","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/RLI.0b013e31824c86a3","article-title":"Metal artifact reduction by dual-energy computed tomography using energetic extrapolation: a systematically optimized protocol","volume":"47","year":"2012","journal-title":"Invest Radiol"},{"key":"bib36-20230926","doi-asserted-by":"crossref","first-page":"e0142185","DOI":"10.1371\/journal.pone.0142185","article-title":"Image quality and radiation dose of CT coronary angiography with automatic tube current modulation and strong adaptive iterative dose reduction three-dimensional (AIDR3D)","volume":"10","year":"2015","journal-title":"PLoS One"},{"key":"bib37-20230926","article-title":"Organ-based tube current modulation in a clinical context: dose reduction may be largely overestimated in breast tissue","year":"2015","journal-title":"Eur Radiol"},{"key":"bib38-20230926","doi-asserted-by":"crossref","first-page":"6572","DOI":"10.1118\/1.4933197","article-title":"Technical note: phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique","volume":"42","year":"2015","journal-title":"Med Phys"},{"key":"bib39-20230926","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1016\/j.ejrad.2015.01.019","article-title":"Whole-body CT with high heat-capacity x-ray tube and automated tube current modulation\u2014effect of tube current limitation on contrast enhancement, image quality and radiation dose","volume":"84","year":"2015","journal-title":"Eur J Radiol"},{"key":"bib40-20230926","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1093\/rpd\/ncu340","article-title":"Effect of tube current modulation for dose estimation using a simulation tool on body CT examination","volume":"167","year":"2015","journal-title":"Radiat Prot Dosimetry"},{"key":"bib41-20230926","first-page":"5135","article-title":"Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study","volume":"16","year":"2015","journal-title":"J Appl Clin Med Phys"},{"key":"bib42-20230926","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1007\/s00247-015-3510-x","article-title":"Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction","volume":"46","year":"2016","journal-title":"Pediatr Radiol"},{"key":"bib43-20230926","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1097\/RLI.0000000000000093","article-title":"Very low-dose (0.15 mGy) chest CT protocols using the COPDGene 2 test object and a third-generation dual-source CT scanner with corresponding third-generation iterative reconstruction software","volume":"50","year":"2015","journal-title":"Invest Radiol"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004424-201610000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T17:45:48Z","timestamp":1695750348000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004424-201610000-00004"}},"subtitle":["A New Technical (Split Filter) Approach for Bone Removal"],"short-title":[],"issued":{"date-parts":[[2016,10]]},"references-count":43,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000290","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2016,10]]}}}