{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T12:46:03Z","timestamp":1790081163868,"version":"4.0.1"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2017,8]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The aims of this study were to compare virtual monoenergetic images and polyenergetic images reconstructed from unenhanced dual-layer detector computed tomography (DLCT) of the head and to determine kiloelectron volt levels that optimize image quality, particularly the gray-white matter contrast, and reduce beam hardening artifacts caused by the skull.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods<\/jats:title>\n            <jats:p>Institutional review board approval was obtained. Forty patients that received DLCT were included in this retrospective study; of these patients, 22 were women and 18 were men. The average age was 61.5 \u00b1 14.3 years. Virtual monoenergetic images were reconstructed from spectral base images at 40 keV to 120 keV. To calculate signal-to-noise ratio and contrast-to-noise ratio, attenuation and standard deviation of supratentorial gray and white matter were measured in virtual monoenergetic and polyenergetic images. Beam hardening artifacts were detected close to the calvarium and in the posterior fossa. Two radiologists rated the assessment of gray-white matter differentiation and of the subcalvarial space, as well as the artifacts caused by the skull and image noise. Student <jats:italic toggle=\"yes\">t<\/jats:italic> test and Wilcoxon test were used to determine significance.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Compared with polyenergetic images, superior signal-to-noise ratio and superior contrast-to-noise ratio of gray and white matter were observed in virtual monoenergetic images at low kiloelectron volt levels (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.0001). Subcalvarial artifacts were significantly lower at 120 keV (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.02). Artifacts measured in the posterior fossa were generally lower at high kiloelectron volt levels; however, no statistical significance was detected. Virtual monoenergetic images were rated superior to polyenergetic images in regard to all 4 criteria (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.0001). The observers reported an optimal radiological assessment of gray-white matter differentiation at 65 keV and optimal assessment of subcalvarial space at 120 keV.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>In comparison to polyenergetic images, virtual monoenergetic images reconstructed from unenhanced DLCT of the head at 65 keV and 120 keV allow to optimize gray-white matter contrast and reduce beam hardening artifacts caused by the skull, respectively.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rli.0000000000000367","type":"journal-article","created":{"date-parts":[[2017,4,19]],"date-time":"2017-04-19T13:02:16Z","timestamp":1492606936000},"page":"470-476","source":"Crossref","is-referenced-by-count":74,"title":["Improvement of Image Quality in Unenhanced Dual-Layer CT of the Head Using Virtual Monoenergetic Images Compared With Polyenergetic Single-Energy CT"],"prefix":"10.1097","volume":"52","author":[{"given":"Victor","family":"Neuhaus","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nuran","family":"Abdullayev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nils","family":"Gro\u00dfe Hokamp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregor","family":"Pahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Kabbasch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anastasios","family":"Mpotsaris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Maintz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Borggrefe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20230926","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.2214\/ajr.141.6.1227","article-title":"Early CT findings of global central nervous system hypoperfusion","volume":"141","year":"1983","journal-title":"AJR Am J Roentgenol"},{"key":"bib2-20230926","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1016\/j.jemermed.2012.10.001","article-title":"Emergency diagnosis of subarachnoid hemorrhage: an evidence-based debate","volume":"44","year":"2013","journal-title":"J Emerg Med"},{"key":"bib3-20230926","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/S0140-6736(07)60151-2","article-title":"Magnetic resonance imaging and computed tomography in emergency assessment of patients with suspected acute stroke: a prospective comparison","volume":"369","year":"2007","journal-title":"Lancet"},{"key":"bib4-20230926","doi-asserted-by":"crossref","first-page":"2032","DOI":"10.1161\/STR.0000000000000069","article-title":"Guidelines for the management of spontaneous intracerebral hemorrhage: a guideline for healthcare professionals from the American Heart Association\/American Stroke Association","volume":"46","year":"2015","journal-title":"Stroke"},{"key":"bib5-20230926","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1088\/0031-9155\/21\/3\/004","article-title":"Beam hardening in x-ray reconstructive tomography","volume":"21","year":"1976","journal-title":"Phys Med Biol"},{"key":"bib6-20230926","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1118\/1.595111","article-title":"The effects of scatter in x-ray computed tomography","volume":"9","year":"1982","journal-title":"Med Phys"},{"key":"bib7-20230926","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1097\/00004728-199105000-00007","article-title":"Cranial CT artifacts and gantry angulation","volume":"15","year":"1991","journal-title":"J Comput Assist Tomogr"},{"key":"bib8-20230926","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1148\/radiology.148.1.6856849","article-title":"Computed tomography: beam hardening and environmental density artifact","volume":"148","year":"1983","journal-title":"Radiology"},{"key":"bib9-20230926","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1148\/rg.246045065","article-title":"Artifacts in CT: recognition and avoidance","volume":"24","year":"2004","journal-title":"Radiographics"},{"key":"bib10-20230926","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1007\/s00330-005-2919-2","article-title":"First performance evaluation of a dual-source CT (DSCT) system","volume":"16","year":"2006","journal-title":"Eur Radiol"},{"key":"bib11-20230926","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/RLI.0b013e31824c86a3","article-title":"Metal artifact reduction by dual-energy computed tomography using energetic extrapolation: a systematically optimized protocol","volume":"47","year":"2012","journal-title":"Invest Radiol"},{"key":"bib12-20230926","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/RLI.0000000000000306","article-title":"Improving CT-based PET attenuation correction in the vicinity of metal implants by an iterative metal artifact reduction algorithm of CT data and its comparison to dual-energy-based strategies: a phantom study","volume":"52","year":"2017","journal-title":"Invest Radiol"},{"key":"bib13-20230926","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1148\/radiol.12111604","article-title":"Virtual monochromatic reconstruction of dual-energy unenhanced head CT at 65\u201375 keV maximizes image quality compared with conventional polychromatic CT","volume":"266","year":"2013","journal-title":"Radiology"},{"key":"bib14-20230926","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.acra.2013.12.006","article-title":"Optimization of kiloelectron volt settings in cerebral and cervical dual-energy CT angiography determined with virtual monoenergetic imaging","volume":"21","year":"2014","journal-title":"Acad Radiol"},{"key":"bib15-20230926","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/j.ejrad.2016.01.015","article-title":"Carotid dual-energy CT angiography: evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels","volume":"85","year":"2016","journal-title":"Eur J Radiol"},{"key":"bib16-20230926","doi-asserted-by":"crossref","first-page":"1994","DOI":"10.3174\/ajnr.A2654","article-title":"Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kVp acquisition","volume":"32","year":"2011","journal-title":"AJNR Am J Neuroradiol"},{"key":"bib17-20230926","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1097\/RLI.0000000000000290","article-title":"Dual-energy computed tomography angiography of the head and neck with single-source computed tomography: a new technical (split filter) approach for bone removal","volume":"51","year":"2016","journal-title":"Invest Radiol"},{"key":"bib18-20230926","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1097\/RLI.0000000000000300","article-title":"Dual-energy computed tomography for the characterization of intracranial hemorrhage and calcification: a systematic approach in a phantom system","volume":"52","year":"2017","journal-title":"Invest Radiol"},{"key":"bib19-20230926","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1088\/0031-9155\/21\/5\/002","article-title":"Energy-selective reconstructions in x-ray computerized tomography","volume":"21","year":"1976","journal-title":"Phys Med Biol"},{"key":"bib20-20230926","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1148\/radiol.14131480","article-title":"State of the art: dual-energy CT of the abdomen","volume":"271","year":"2014","journal-title":"Radiology"},{"key":"bib21-20230926","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1148\/rg.314105159","article-title":"Dual-energy (spectral) CT: applications in abdominal imaging","volume":"31","year":"2011","journal-title":"Radiographics"},{"issue":"(5 Suppl)","key":"bib22-20230926","first-page":"S9","article-title":"Dual-energy CT-based monochromatic imaging","volume":"199","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"bib23-20230926","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-energy CT: principles, technical approaches, and clinical applications","volume":"276","year":"2015","journal-title":"Radiology"},{"key":"bib24-20230926","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1097\/RCT.0000000000000350","article-title":"Qualitative comparison of noncontrast head dual-energy computed tomography using rapid voltage switching technique and conventional computed tomography","volume":"40","year":"2016","journal-title":"J Comput Assist Tomogr"},{"key":"bib25-20230926","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.neurad.2016.04.001","article-title":"Utilizing dual energy CT to improve CT diagnosis of posterior fossa ischemia","volume":"43","year":"2016","journal-title":"J Neuroradiol"},{"key":"bib26-20230926","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1097\/RCT.0b013e3182058d5c","article-title":"High-definition CT Gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction","volume":"35","year":"2011","journal-title":"J Comput Assist Tomogr"},{"key":"bib27-20230926","doi-asserted-by":"crossref","first-page":"3818","DOI":"10.1118\/1.3157235","article-title":"Image-based dual energy CT using optimized precorrection functions: a practical new approach of material decomposition in image domain","volume":"36","year":"2009","journal-title":"Med Phys"},{"key":"bib28-20230926","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1118\/1.595025","article-title":"Generalized image combinations in dual kVp digital radiography","volume":"8","year":"1981","journal-title":"Med Phys"},{"key":"bib29-20230926","doi-asserted-by":"crossref","first-page":"051909","DOI":"10.1118\/1.4870375","article-title":"Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization","volume":"41","year":"2014","journal-title":"Med Phys"},{"key":"bib30-20230926","first-page":"745","article-title":"Iterative dual energy material decomposition from spatial mismatched raw data sets","volume":"22","year":"2014","journal-title":"J Xray Sci Technol"},{"key":"bib31-20230926","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1109\/42.7785","article-title":"An algorithm for noise suppression in dual energy CT material density images","volume":"7","year":"1988","journal-title":"IEEE Trans Med Imaging"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004424-201708000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T17:35:17Z","timestamp":1695749717000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004424-201708000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8]]},"references-count":31,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000367","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2017,8]]}}}