{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T03:22:52Z","timestamp":1762917772729},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2017,10]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The aim of this study was to assess the applicability of Dixon radial volumetric encoding (Dixon-RAVE) for comprehensive dynamic contrast-enhanced 3D magnetic resonance imaging (MRI) of the breast using a combination of radial sampling, model-based fat\/water separation, compressed sensing, and parallel imaging.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods<\/jats:title>\n            <jats:p>In this Health Insurance Portability and Accountability Act\u2013compliant prospective study, 24 consecutive patients underwent bilateral breast MRI, including both conventional fat-suppressed and non\u2013fat-suppressed precontrast T1-weighted volumetric interpolated breath-hold examination (VIBE). Afterward, 1 continuous Dixon-RAVE scan was performed with the proposed approach while the contrast agent was injected. This scan was immediately followed by the acquisition of 4 conventional fat-saturated VIBE scans. From the comprehensive Dixon-RAVE data set, different image contrasts were reconstructed that are comparable to the separate conventional VIBE scans.<\/jats:p>\n            <jats:p>Two radiologists independently rated image quality, conspicuity of fibroglandular tissue from fat (FG), and degree of fat suppression (FS) on a 5-point Likert-type scale for the following 3 comparisons: precontrast fat-suppressed (pre-FS), precontrast non\u2013fat-suppressed (pre-NFS), and dynamic fat-suppressed (dyn-FS) images.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>When scores were averaged over readers, Dixon-RAVE achieved significantly higher (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001) degree of fat suppression compared with VIBE, for both pre-FS (4.25 vs 3.67) and dyn-FS (4.10 vs 3.46) images. Although Dixon-RAVE had lower image quality score compared with VIBE for the pre-FS (3.56 vs 3.67, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.490), the pre-NFS (3.54 vs 3.88, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.009), and the dyn-FS images (3.06 vs 3.67, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001), acceptable or better diagnostic quality was achieved (score \u2265 3). The FG score for Dixon-RAVE in comparison to VIBE was significantly higher for the pre-FS image (4.23 vs 3.85, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.044), lower for the pre-NFS image (3.98 vs 4.25, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.054), and higher for the dynamic fat-suppressed image (3.90 vs 3.85, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.845).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Dixon-RAVE can serve as a one-stop-shop approach for comprehensive T1-weighted breast MRI with diagnostic image quality, high spatiotemporal resolution, reduced overall scan time, and improved fat suppression compared with conventional imaging.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rli.0000000000000375","type":"journal-article","created":{"date-parts":[[2017,4,11]],"date-time":"2017-04-11T14:42:39Z","timestamp":1491921759000},"page":"583-589","source":"Crossref","is-referenced-by-count":13,"title":["Comprehensive Dynamic Contrast-Enhanced 3D Magnetic Resonance Imaging of the Breast With Fat\/Water Separation and High Spatiotemporal Resolution Using Radial Sampling, Compressed Sensing, and Parallel Imaging"],"prefix":"10.1097","volume":"52","author":[{"given":"Thomas","family":"Benkert","sequence":"first","affiliation":[{"name":"From the *Center for Advanced Imaging Innovation and Research (CAIR); and \u2020Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai Tobias","family":"Block","sequence":"additional","affiliation":[{"name":"From the *Center for Advanced Imaging Innovation and Research (CAIR); and \u2020Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samantha","family":"Heller","sequence":"additional","affiliation":[{"name":"From the *Center for Advanced Imaging Innovation and Research (CAIR); and \u2020Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Melanie","family":"Moccaldi","sequence":"additional","affiliation":[{"name":"From the *Center for Advanced Imaging Innovation and Research (CAIR); and \u2020Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel K.","family":"Sodickson","sequence":"additional","affiliation":[{"name":"From the *Center for Advanced Imaging Innovation and Research (CAIR); and \u2020Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sungheon Gene","family":"Kim","sequence":"additional","affiliation":[{"name":"From the *Center for Advanced Imaging Innovation and Research (CAIR); and \u2020Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linda","family":"Moy","sequence":"additional","affiliation":[{"name":"From the *Center for Advanced Imaging Innovation and Research (CAIR); and \u2020Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20231021","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1097\/RMR.0b013e31818a40a5","article-title":"A review of current evidence-based clinical applications for breast magnetic resonance imaging","volume":"19","year":"2008","journal-title":"Top Magn Reson Imaging"},{"key":"bib2-20231021","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1148\/radiol.2363040811","article-title":"Dynamic bilateral contrast-enhanced MR imaging of the breast: trade-off between spatial and temporal resolution","volume":"236","year":"2005","journal-title":"Radiology"},{"key":"bib3-20231021","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1002\/mrm.24980","article-title":"Golden-angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI","volume":"72","year":"2014","journal-title":"Magn Reson Med"},{"key":"bib4-20231021","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1002\/jmri.24961","article-title":"Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast","volume":"43","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"bib5-20231021","article-title":"Comparison of conventional DCE-MRI and a novel golden-angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"bib6-20231021","first-page":"1257","article-title":"A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings","volume":"30","year":"2012","journal-title":"Magn Reson Med"},{"key":"bib7-20231021","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1097\/RLI.0000000000000057","article-title":"A novel approach to contrast-enhanced breast magnetic resonance imaging for screening: high-resolution ultrafast dynamic imaging","volume":"49","year":"2014","journal-title":"Invest Radiol"},{"key":"bib8-20231021","doi-asserted-by":"crossref","first-page":"2213","DOI":"10.1007\/s00330-014-3189-7","article-title":"Fat saturation in dynamic breast MRI at 3 Tesla: is the Dixon technique superior to spectral fat saturation? A visual grading characteristics study","volume":"24","year":"2014","journal-title":"Eur Radiol"},{"key":"bib9-20231021","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1097\/RLI.0b013e31817ee53a","article-title":"Feasibility of gadofosveset-enhanced steady-state magnetic resonance angiography of the peripheral vessels at 3 Tesla with dixon fat saturation","volume":"43","year":"2008","journal-title":"Invest Radiol"},{"key":"bib10-20231021","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.clinimag.2013.11.005","article-title":"Clinical application of 3D VIBECAIPI-DIXON for non-enhanced imaging of the pancreas compared to a standard 2D fat-saturated FLASH","volume":"38","year":"2014","journal-title":"Clin Imaging"},{"key":"bib11-20231021","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1002\/jmri.23663","article-title":"Development and evaluation of TWIST Dixon for dynamic contrast-enhanced (DCE) MRI with improved acquisition efficiency and fat suppression","volume":"36","year":"2012","journal-title":"J Magn Reson Imaging"},{"key":"bib12-20231021","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1002\/jmri.24062","article-title":"Application of time-resolved angiography with stochastic trajectories (TWIST)-Dixon in dynamic contrast-enhanced (DCE) breast MRI","volume":"38","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"bib13-20231021","doi-asserted-by":"crossref","first-page":"1162","DOI":"10.1007\/s00330-014-3451-z","article-title":"Influence of scan duration on the estimation of pharmacokinetic parameters for breast lesions: a study based on CAIPIRINHA-Dixon-TWIST-VIBE technique","volume":"25","year":"2015","journal-title":"Eur Radiol"},{"key":"bib14-20231021","doi-asserted-by":"crossref","first-page":"1242","DOI":"10.1002\/mrm.21901","article-title":"Optimal k-space sampling for dyn amic contrast-enhanced MRI with an application to MR renography","volume":"61","year":"2009","journal-title":"Magn Reson Med"},{"key":"bib15-20231021","article-title":"Free-breathing volumetric fat\/water separation by combining radial sampling, compressed sensing, and parallel imaging","year":"2016","journal-title":"Magn Reson Med"},{"key":"bib16-20231021","first-page":"93","article-title":"Application of fourier transform spectroscopy to magnetic resonance","volume":"37","year":"2004","journal-title":"Revi Sci Instrum"},{"key":"bib17-20231021","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1109\/TMI.2006.885337","article-title":"An optimal radial profile order based on the golden ratio for time-resolved MRI","volume":"26","year":"2007","journal-title":"IEEE Trans Med Imaging"},{"key":"bib18-20231021","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1109\/TSP.2002.807005","article-title":"Nonuniform fast Fourier transforms using min-max interpolation","volume":"51","year":"2003","journal-title":"IEEE Trans Signal Process"},{"key":"bib19-20231021","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1002\/mrm.22563","article-title":"Compressed sensing for chemical shift-based water-fat separation","volume":"64","year":"2010","journal-title":"Magn Reson Med"},{"key":"bib20-20231021","doi-asserted-by":"crossref","first-page":"1659","DOI":"10.1002\/mrm.22385","article-title":"Three-point Dixon method enables whole-body water and fat imaging of obese subjects","volume":"63","year":"2010","journal-title":"Magn Reson Med"},{"key":"bib22-20231021","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1002\/mrm.21237","article-title":"Array compression for MRI with large coil arrays","volume":"57","year":"2007","journal-title":"Magn Reson Med"},{"key":"bib23-20231021","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1002\/mrm.1910180211","article-title":"Three-point dixon technique for true water\/fat decomposition with B0 inhomogeneity correction","volume":"18","year":"1991","journal-title":"Magn Reson Med"},{"key":"bib25-20231021","doi-asserted-by":"crossref","first-page":"87","DOI":"10.13104\/jksmrm.2014.18.2.87","article-title":"Towards routine clinical use of radial stack-of-stars 3D gradient-echo sequences for reducing motion sensitivity","volume":"18","year":"2014","journal-title":"J Korean Soc Magn Reson Med"},{"key":"bib26-20231021","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1002\/jmri.24568","article-title":"Chemical shift encoding-based water-fat separation methods","volume":"40","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"bib27-20231021","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1097\/RLI.0000000000000329","article-title":"Novel high spatiotemporal resolution versus standard-of-care dynamic contrast-enhanced breast MRI: comparison of image quality","volume":"52","year":"2017","journal-title":"Invest Radiol"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004424-201710000-00003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,21]],"date-time":"2023-10-21T06:27:47Z","timestamp":1697869667000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004424-201710000-00003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10]]},"references-count":25,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000375","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2017,10]]}}}