{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T12:46:43Z","timestamp":1771332403039,"version":"3.50.1"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>We hypothesize that, compared with filtered back projection (FBP), iterative reconstruction (IR) increases the detected volume of uric acid, which serves as a measure of the sensitivity of the method, and therefore allows examinations with lower radiation exposure. Thus, the aim of our study was to evaluate the role of IR in dual-energy computed tomography (DECT) for gout assessment and volumetry in an ex vivo gout model using an epoxy phantom and a biophantom.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods<\/jats:title>\n            <jats:p>We prepared specimens with different concentrations of monosodium uric acid in ultrasound gel (30%\u201350%) and inserted them into an epoxy-based phantom and a porcine foreleg. Computed tomography scanning was performed on a 320-row single-source DECT scanner in volume mode with an ascending order of tube currents. Image data sets were reconstructed using FBP and IR with 2 iteration levels (IR1 and IR2). Measurements in regions of interest (ROIs) and volumetric measurements were performed using either fixed parameters for the analysis software (epoxy phantom) or parameters specifically adapted for each data set (porcine phantom). Seven retrospectively identified clinical data sets were used for validation in patients. Rm-ANOVA was used for statistical analysis. No institutional review board approval was required.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>We found no differences in Hounsfield units between the different reconstruction algorithms (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.09 and 0.05 for 80 and 135 kVp, respectively) and the calculated dual-energy gradient (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.27). Filtered back projection detected less uric acid compared with IR (with fixed parameters: 6.0 \u00b1 0.3 cm<jats:sup>3<\/jats:sup> for FBP and 6.1 \u00b1 0.2 for IR1 and IR2; with adapted thresholds: 1.2 \u00b1 0.3 cm<jats:sup>3<\/jats:sup> for FBP and 1.8 \u00b1 0.1 and 2.0 \u00b1 0.1 for IR1 and IR2, respectively). The differences were significant for all measurements (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0003). Also in the test cases, FBP detected significantly fewer tophi (mean volume, 1.38 \u00b1 2.1 cm<jats:sup>3<\/jats:sup>) compared with IR1 (1.86 \u00b1 2.9) and IR2 (2.07 \u00b1 3.1) (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.04).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Iterative reconstruction has the potential to improve the sensitivity of a DECT scan for gouty tophi, to decrease radiation exposure, or to combine both options.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rli.0000000000000402","type":"journal-article","created":{"date-parts":[[2017,7,20]],"date-time":"2017-07-20T15:29:37Z","timestamp":1500564577000},"page":"6-12","source":"Crossref","is-referenced-by-count":15,"title":["Iterative Reconstruction May Improve Diagnosis of Gout"],"prefix":"10.1097","volume":"53","author":[{"given":"Torsten","family":"Diekhoff","sequence":"first","affiliation":[{"name":"From the *Department of Radiology, Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Campus Mitte, Humboldt-Universit\u00e4t zu Berlin, Freie Universit\u00e4t Berlin, Berlin, Germany; and \u2020Toshiba Medical Systems Europe BV, Center for Medical Research & Development Europe, Zoetermeer, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian","family":"Kotlyarov","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Campus Mitte, Humboldt-Universit\u00e4t zu Berlin, Freie Universit\u00e4t Berlin, Berlin, Germany; and \u2020Toshiba Medical Systems Europe BV, Center for Medical Research & Development Europe, Zoetermeer, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00fcrgen","family":"Mews","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Campus Mitte, Humboldt-Universit\u00e4t zu Berlin, Freie Universit\u00e4t Berlin, Berlin, Germany; and \u2020Toshiba Medical Systems Europe BV, Center for Medical Research & Development Europe, Zoetermeer, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernd","family":"Hamm","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Campus Mitte, Humboldt-Universit\u00e4t zu Berlin, Freie Universit\u00e4t Berlin, Berlin, Germany; and \u2020Toshiba Medical Systems Europe BV, Center for Medical Research & Development Europe, Zoetermeer, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kay-Geert Armin","family":"Hermann","sequence":"additional","affiliation":[{"name":"From the *Department of Radiology, Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Campus Mitte, Humboldt-Universit\u00e4t zu Berlin, Freie Universit\u00e4t Berlin, Berlin, Germany; and \u2020Toshiba Medical Systems Europe BV, Center for Medical Research & Development Europe, Zoetermeer, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20231021","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1136\/ard.2008.099713","article-title":"Dual energy computed tomography in tophaceous gout","volume":"68","year":"2009","journal-title":"Ann Rheum Dis"},{"key":"bib2-20231021","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1136\/annrheumdis-2011-200976","article-title":"Dual energy CT in gout: a prospective validation study","volume":"71","year":"2012","journal-title":"Ann Rheum Dis"},{"key":"bib3-20231021","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1007\/s11926-012-0301-3","article-title":"Dual-energy computed tomography for gout diagnosis and management","volume":"15","year":"2013","journal-title":"Curr Rheumatol Rep"},{"key":"bib4-20231021","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1093\/rheumatology\/kew383","article-title":"Relationship of bone erosion with the urate and soft tissue components of the tophus in gout: a dual energy computed tomography study","volume":"56","year":"2017","journal-title":"Rheumatology (Oxford)"},{"key":"bib5-20231021","article-title":"Diagnostic accuracy of dual-energy computed tomography in patients with gout: a meta-analysis","year":"2017","journal-title":"Semin Arthritis Rheum"},{"key":"bib6-20231021","doi-asserted-by":"crossref","first-page":"20160408","DOI":"10.1259\/bjr.20160408","article-title":"Determining the composition of urinary tract calculi using stone-targeted dual-energy CT: evaluation of a low-dose scanning protocol in a clinical environment","volume":"89","year":"2016","journal-title":"Br J Radiol"},{"key":"bib7-20231021","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1097\/RLI.0b013e31829e3932","article-title":"Determining the radiation dose reduction potential for coronary calcium scanning with computed tomography: an anthropomorphic phantom study comparing filtered backprojection and the adaptive iterative dose reduction algorithm for image reconstruction","volume":"48","year":"2013","journal-title":"Invest Radiol"},{"key":"bib8-20231021","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/RLI.0b013e31823a86d5","article-title":"Radiation exposure and image quality of normal computed tomography brain images acquired with automated and organ-based tube current modulation multiband filtering and iterative reconstruction","volume":"47","year":"2012","journal-title":"Invest Radiol"},{"key":"bib9-20231021","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/RLI.0000000000000099","article-title":"Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib10-20231021","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1186\/s12891-016-0943-9","article-title":"Dual-energy computed tomography has limited sensitivity for non-tophaceous gout: a comparison study with tophaceous gout","volume":"17","year":"2016","journal-title":"BMC Musculoskelet Disord"},{"key":"bib11-20231021","doi-asserted-by":"crossref","first-page":"1829","DOI":"10.1016\/j.ejrad.2016.08.004","article-title":"Single source dual-energy computed tomography in the diagnosis of gout: diagnostic reliability in comparison to digital radiography and conventional computed tomography of the feet","volume":"85","year":"2016","journal-title":"Eur J Radiol"},{"key":"bib12-20231021","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1136\/annrheumdis-2013-205095","article-title":"Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study","volume":"74","year":"2015","journal-title":"Ann Rheum Dis"},{"key":"bib13-20231021","doi-asserted-by":"crossref","first-page":"20150300","DOI":"10.1259\/bjr.20150300","article-title":"The feasibility of dual-energy CT in differentiation of vertebral compression fractures","volume":"89","year":"2016","journal-title":"Br J Radiol"},{"key":"bib14-20231021","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1097\/RCT.0000000000000173","article-title":"Malignant bone tumor intramedullary invasion: evaluation with dual-energy computed tomography in a rabbit model","volume":"39","year":"2015","journal-title":"J Comput Assist Tomogr"},{"key":"bib15-20231021","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1148\/radiol.10091230","article-title":"Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions\u2014feasibility study 1","volume":"256","year":"2010","journal-title":"Radiology"},{"key":"bib16-20231021","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1148\/radiol.2017162165","article-title":"Vertebral compression fractures: third-generation dual-energy CT for detection of bone marrow edema at visual and quantitative analyses","volume":"284","year":"2017","journal-title":"Radiology"},{"key":"bib17-20231021","first-page":"161063","article-title":"Detection of bone marrow edema in nondisplaced hip fractures: utility of a virtual unenhanced dual-energy CT application","year":"2017","journal-title":"Radiology"},{"key":"bib18-20231021","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1177\/0284185116631182","article-title":"Combined use of iterative reconstruction and monochromatic imaging in spinal fusion CT images","volume":"58","year":"2017","journal-title":"Acta Radiol"},{"key":"bib19-20231021","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/RLI.0000000000000306","article-title":"Improving CT-based PET attenuation correction in the vicinity of metal implants by an iterative metal artifact reduction algorithm of CT data and its comparison to dual-energy-based strategies: a phantom study","volume":"52","year":"2017","journal-title":"Invest Radiol"},{"key":"bib20-20231021","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1118\/1.4889566","article-title":"TH-A-18C-07: noise suppression in material decomposition for dual-energy CT","volume":"41","year":"2014","journal-title":"Med Phys"},{"key":"bib21-20231021","doi-asserted-by":"crossref","first-page":"051909","DOI":"10.1118\/1.4870375","article-title":"Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization","volume":"41","year":"2014","journal-title":"Med Phys"},{"key":"bib22-20231021","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/RHU.0000000000000292","article-title":"Dual-energy computed tomography demonstrating destructive calcium pyrophosphate deposition disease of the distal radioulnar joint mimicking tophaceous gout","volume":"21","year":"2015","journal-title":"J Clin Rheumatol"},{"key":"bib23-20231021","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1148\/radiol.14132903","article-title":"Estimates of effective dose for CT scans of the lower extremities","volume":"273","year":"2014","journal-title":"Radiology"},{"key":"bib24-20231021","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1007\/s00256-015-2204-7","article-title":"First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference","volume":"44","year":"2015","journal-title":"Skeletal Radiol"},{"key":"bib25-20231021","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1097\/RLI.0000000000000002","article-title":"Feasibility of single-source dual-energy computed tomography for urinary stone characterization and value of iterative reconstructions","volume":"49","year":"2014","journal-title":"Invest Radiol"},{"key":"bib26-20231021","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1097\/RLI.0b013e31826585bb","article-title":"Iodine quantification using dual-energy multidetector computed tomography imaging: phantom study assessing the impact of iterative reconstruction schemes and patient habitus on accuracy","volume":"47","year":"2012","journal-title":"Invest Radiol"},{"key":"bib27-20231021","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1007\/s00330-014-3447-8","article-title":"Interdependencies of acquisition, detection, and reconstruction techniques on the accuracy of iodine quantification in varying patient sizes employing dual-energy CT","volume":"25","year":"2015","journal-title":"Eur Radiol"},{"issue":"suppl 1","key":"bib28-20231021","first-page":"7","article-title":"Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes","volume":"28","year":"2012","journal-title":"Int J Cardiovasc Imaging"},{"key":"bib29-20231021","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/RLI.0000000000000109","article-title":"The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib30-20231021","first-page":"541","article-title":"Detection of uric acid depositing in tophaceous gout using a new dual energy spectral CT technology","volume":"22","year":"2014","journal-title":"J Xray Sci Technol"},{"key":"bib31-20231021","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1097\/RLI.0000000000000367","article-title":"Improvement of image quality in unenhanced dual-layer CT of the head using virtual monoenergetic images compared with polyenergetic single-energy CT","volume":"52","year":"2017","journal-title":"Invest Radiol"},{"key":"bib32-20231021","article-title":"Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT","year":"2017","journal-title":"Eur Radiol"},{"key":"bib33-20231021","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s00256-016-2533-1","article-title":"Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout","volume":"46","year":"2017","journal-title":"Skeletal Radiol"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004424-201801000-00002","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,21]],"date-time":"2023-10-21T06:20:16Z","timestamp":1697869216000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004424-201801000-00002"}},"subtitle":["An Ex Vivo (Bio)Phantom Dual-Energy Computed Tomography Study"],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000402","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2018,1]]}}}