{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T13:36:49Z","timestamp":1781530609565,"version":"3.54.1"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The aims of this study were to prospectively evaluate image quality, duct visibility, and diagnostic performance in duct-related pathologies of compressed-sensing (CS) accelerated 3-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) prototype protocols and compare these with those of conventional 3D MRCP protocol in patients with suspected pancreatic diseases.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Material and Methods<\/jats:title>\n            <jats:p>The institutional review board approved this prospective study and all patients provided written informed consent. A total of 80 patients (47 men and 33 women; median age, 57 years; age range, 24\u201387 years) underwent 3D MRCP at 3.0 T. Three protocols were performed in each patient in random order: CS breath-hold (BH) protocol, CS navigator-triggered (NT) protocol, and conventional NT protocol. The acquisition time of each protocol was recorded. Image quality and duct visibility were independently rated in random order on a 5-point scale by 2 radiologists, who were blinded to the protocols. Receiver operating characteristic curves were generated, and area under the curve (A<jats:sub>z<\/jats:sub> value) was used to compare the diagnostic performance of each protocol in duct-related pathologies.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Acquisition time was 17 seconds for the CS-BH and 134.1 \u00b1 33.5 seconds for the CS-NT protocol, both being significantly shorter than the conventional NT protocol (364.7 \u00b1 78.4 seconds; both <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.01). The CS-BH MRCP protocol showed significantly less artifacts compared with the CS-NT and conventional NT protocols (both <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.01). Visualization of bile ducts was comparable in all 3 protocols, whereas CS-NT and conventional NT MRCP depicted pancreatic duct better than CS-BH MRCP did (for proximal, middle, and distal segment; all <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05). Compressed-sensing-NT MRCP had the highest diagnostic performance for detecting ductal anomalies, long-segment duct stenosis, abnormal branch ducts, and communication between cystic lesion and pancreatic duct (mean A<jats:sub>z<\/jats:sub> value, 0.943\u20130.983).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Compressed-sensing MRCP is feasible in patients with suspected pancreatic diseases. Compressed-sensing-NT MRCP demonstrated superior diagnostic accuracy for duct-related pathologies.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rli.0000000000000421","type":"journal-article","created":{"date-parts":[[2017,10,3]],"date-time":"2017-10-03T22:24:27Z","timestamp":1507069467000},"page":"150-157","source":"Crossref","is-referenced-by-count":55,"title":["Compressed-Sensing Accelerated 3-Dimensional Magnetic Resonance Cholangiopancreatography"],"prefix":"10.1097","volume":"53","author":[{"given":"Liang","family":"Zhu","sequence":"first","affiliation":[{"name":"From the Departments of *Radiology and \u2020Gastroenterology, Peking Union Medical College Hospital, Beijing, China; \u2021Siemens Healthcare Gmbh, Erlangen, Germany; and \u00a7MR collaborations NE Asia, Siemens Healthcare, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xi","family":"Wu","sequence":"additional","affiliation":[{"name":"From the Departments of *Radiology and \u2020Gastroenterology, Peking Union Medical College Hospital, Beijing, China; \u2021Siemens Healthcare Gmbh, Erlangen, Germany; and \u00a7MR collaborations NE Asia, Siemens Healthcare, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhaoyong","family":"Sun","sequence":"additional","affiliation":[{"name":"From the Departments of *Radiology and \u2020Gastroenterology, Peking Union Medical College Hospital, Beijing, China; \u2021Siemens Healthcare Gmbh, Erlangen, Germany; and \u00a7MR collaborations NE Asia, Siemens Healthcare, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengyu","family":"Jin","sequence":"additional","affiliation":[{"name":"From the Departments of *Radiology and \u2020Gastroenterology, Peking Union Medical College Hospital, Beijing, China; \u2021Siemens Healthcare Gmbh, Erlangen, Germany; and \u00a7MR collaborations NE Asia, Siemens Healthcare, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elisabeth","family":"Weiland","sequence":"additional","affiliation":[{"name":"From the Departments of *Radiology and \u2020Gastroenterology, Peking Union Medical College Hospital, Beijing, China; \u2021Siemens Healthcare Gmbh, Erlangen, Germany; and \u00a7MR collaborations NE Asia, Siemens Healthcare, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esther","family":"Raithel","sequence":"additional","affiliation":[{"name":"From the Departments of *Radiology and \u2020Gastroenterology, Peking Union Medical College Hospital, Beijing, China; \u2021Siemens Healthcare Gmbh, Erlangen, Germany; and \u00a7MR collaborations NE Asia, Siemens Healthcare, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianyi","family":"Qian","sequence":"additional","affiliation":[{"name":"From the Departments of *Radiology and \u2020Gastroenterology, Peking Union Medical College Hospital, Beijing, China; \u2021Siemens Healthcare Gmbh, Erlangen, Germany; and \u00a7MR collaborations NE Asia, Siemens Healthcare, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huadan","family":"Xue","sequence":"additional","affiliation":[{"name":"From the Departments of *Radiology and \u2020Gastroenterology, Peking Union Medical College Hospital, Beijing, China; \u2021Siemens Healthcare Gmbh, Erlangen, Germany; and \u00a7MR collaborations NE Asia, Siemens Healthcare, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20231021","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1056\/NEJM199907223410407","article-title":"Magnetic resonance cholangiopancreatography","volume":"341","year":"1999","journal-title":"N Engl J Med"},{"key":"bib2-20231021","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1148\/radiology.206.2.9457189","article-title":"Optimal MR cholangiopancreatographic sequence and its clinical application","volume":"206","year":"1998","journal-title":"Radiology"},{"key":"bib3-20231021","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1067\/mge.2002.120324","article-title":"Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree","volume":"55","year":"2002","journal-title":"Gastrointest Endosc"},{"key":"bib4-20231021","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1111\/j.1572-0241.2002.05468.x","article-title":"Comparison between magnetic resonance cholangiopancreatography and ERCP for evaluation of the pancreatic duct","volume":"97","year":"2002","journal-title":"Am J Gastroenterol"},{"key":"bib5-20231021","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.mri.2013.06.008","article-title":"Breath-held MR cholangiopancreatography (MRCP) using a 3D Dixon fat-water separated balanced steady state free precession sequence","volume":"31","year":"2013","journal-title":"Magn Reson Imaging"},{"key":"bib6-20231021","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1002\/jmri.20735","article-title":"Respiratory-triggered MRCP applying parallel acquisition techniques","volume":"24","year":"2006","journal-title":"J Magn Reson Imaging"},{"key":"bib7-20231021","doi-asserted-by":"crossref","first-page":"1564","DOI":"10.2214\/AJR.05.1032","article-title":"Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: feasibility study","volume":"187","year":"2006","journal-title":"AJR Am J Roentgenol"},{"key":"bib8-20231021","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/RCT.0000000000000163","article-title":"Clinical impact of 3-dimensional balanced turbo-field-echo magnetic resonance cholangiopancreatography at 3 T: prospective intraindividual comparison with 3-dimensional turbo-spin-echo magnetic resonance cholangiopancreatography","volume":"39","year":"2015","journal-title":"J Comput Assist Tomogr"},{"key":"bib9-20231021","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1097\/RLI.0000000000000226","article-title":"Compressed sensing 3-dimensional time-of-flight magnetic resonance angiography for cerebral aneurysms: optimization and evaluation","volume":"51","year":"2016","journal-title":"Invest Radiol"},{"key":"bib10-20231021","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/RLI.0000000000000330","article-title":"Speed in clinical magnetic resonance","volume":"52","year":"2017","journal-title":"Invest Radiol"},{"key":"bib11-20231021","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1097\/RLI.0000000000000179","article-title":"Respiratory motion-resolved compressed sensing reconstruction of free-breathing radial acquisition for dynamic liver magnetic resonance imaging","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib12-20231021","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1097\/RLI.0000000000000375","article-title":"Comprehensive dynamic contrast-enhanced 3D magnetic resonance imaging of the breast with fat\/water separation and high spatiotemporal resolution using radial sampling, compressed sensing, and parallel imaging","volume":"52","year":"2017","journal-title":"Invest Radiol"},{"key":"bib13-20231021","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1097\/RLI.0000000000000274","article-title":"Sparse reconstruction techniques in magnetic resonance imaging: methods, applications, and challenges to clinical adoption","volume":"51","year":"2016","journal-title":"Invest Radiol"},{"key":"bib14-20231021","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1097\/RLI.0000000000000221","article-title":"Time-of-flight magnetic resonance angiography with sparse undersampling and iterative reconstruction: comparison with conventional parallel imaging for accelerated imaging","volume":"51","year":"2016","journal-title":"Invest Radiol"},{"key":"bib15-20231021","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1148\/radiol.2016151935","article-title":"Three-dimensional MR cholangiopancreatography in a breath hold with sparsity-based reconstruction of highly undersampled data","volume":"280","year":"2016","journal-title":"Radiology"},{"key":"bib16-20231021","article-title":"Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3 T [published online ahead of print March 11, 2017]","year":"2017","journal-title":"J Magn Reson Imaging"},{"key":"bib17-20231021","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1097\/RLI.0000000000000380","article-title":"Clinical feasibility of 3-dimensional magnetic resonance cholangiopancreatography using compressed sensing: comparison of image quality and diagnostic performance","volume":"52","year":"2017","journal-title":"Invest Radiol"},{"key":"bib18-20231021","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1002\/mrm.22463","article-title":"Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI","volume":"64","year":"2010","journal-title":"Magn Reson Med"},{"key":"bib19-20231021","doi-asserted-by":"crossref","first-page":"2437","DOI":"10.1007\/s00330-015-3644-0","article-title":"Santorinicele: secretin-enhanced magnetic resonance cholangiopancreatography findings before and after minor papilla sphincterotomy","volume":"25","year":"2015","journal-title":"Eur Radiol"},{"key":"bib20-20231021","doi-asserted-by":"crossref","first-page":"1544","DOI":"10.2214\/AJR.05.0774","article-title":"Congenital anomalies and normal variants of the pancreaticobiliary tract and the pancreas in adults: part 2, pancreatic duct and pancreas","volume":"187","year":"2006","journal-title":"AJR Am J Roentgenol"},{"key":"bib21-20231021","doi-asserted-by":"crossref","first-page":"209","DOI":"10.2214\/ajr.179.1.1790209","article-title":"Using MR cholangiopancreatography to reveal anomalous pancreaticobiliary ductal union in infants and children with choledochal cysts","volume":"179","year":"2002","journal-title":"AJR Am J Roentgenol"},{"key":"bib22-20231021","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1177\/028418518302400204","article-title":"Variants of pancreatic duct system of importance in endoscopic retrograde cholangiopancreatography. Observations on autopsy specimens","volume":"24","year":"1983","journal-title":"Acta Radiol Diagn (Stockh)"},{"key":"bib23-20231021","first-page":"806","article-title":"Variations of the pancreatic ducts as a cause of chronic alcoholic pancreatitis; ansa pancreatica","volume":"87","year":"1992","journal-title":"Am J Gastroenterol"},{"key":"bib24-20231021","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s00330-014-3371-y","article-title":"Pancreatic duct abnormalities in focal autoimmune pancreatitis: MR\/MRCP imaging findings","volume":"25","year":"2015","journal-title":"Eur Radiol"},{"key":"bib25-20231021","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1148\/radiol.2211001157","article-title":"Duct-penetrating sign at MRCP: usefulness for differentiating inflammatory pancreatic mass from pancreatic carcinomas","volume":"221","year":"2001","journal-title":"Radiology"},{"key":"bib26-20231021","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1136\/gut.25.7.756","article-title":"Classification of pancreatitis","volume":"25","year":"1984","journal-title":"Gut"},{"key":"bib27-20231021","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/RCT.0b013e3181852193","article-title":"Another dimension in magnetic resonance cholangiopancreatography: comparison of 2- and 3-dimensional magnetic resonance cholangiopancreatography for the evaluation of intraductal papillary mucinous neoplasm of the pancreas","volume":"33","year":"2009","journal-title":"J Comput Assist Tomogr"},{"key":"bib28-20231021","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1148\/radiol.2382041463","article-title":"Intraductal papillary mucinous neoplasm of pancreas: multi-detector row CT with 2D curved reformations\u2014correlation with MRCP","volume":"238","year":"2006","journal-title":"Radiology"},{"key":"bib29-20231021","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1148\/radiology.143.1.7063747","article-title":"The meaning and use of the area under a receiver operating characteristic (ROC) curve","volume":"143","year":"1982","journal-title":"Radiology"},{"key":"bib30-20231021","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1148\/rg.263055164","article-title":"Multimodality imaging of pancreatic and biliary congenital anomalies","volume":"26","year":"2006","journal-title":"Radiographics"},{"key":"bib31-20231021","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1148\/radiology.217.2.r00nv29403","article-title":"Pancreas divisum and \u201csantorinicele\u201d: diagnosis with dynamic MR cholangiopancreatography with secretin stimulation","volume":"217","year":"2000","journal-title":"Radiology"},{"key":"bib32-20231021","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1067\/mge.2000.106889","article-title":"The diagnosis of chronic pancreatitis","volume":"52","year":"2000","journal-title":"Gastrointest Endosc"},{"key":"bib33-20231021","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s11605-007-0367-9","article-title":"CT vs MRCP: optimal classification of IPMN type and extent","volume":"12","year":"2008","journal-title":"J Gastrointest Surg"},{"key":"bib34-20231021","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1002\/mrm.24980","article-title":"Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI","volume":"72","year":"2014","journal-title":"Magn Reson Med"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004424-201803000-00003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,21]],"date-time":"2023-10-21T06:12:29Z","timestamp":1697868749000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004424-201803000-00003"}},"subtitle":["Application in Suspected Pancreatic Diseases"],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":34,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000421","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2018,3]]}}}