{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T03:28:34Z","timestamp":1782185314911,"version":"3.54.5"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2019,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The purpose of this work is to present the data obtained from the first clinical in vivo application of a new dedicated spiral breast computed tomography (B-CT) equipped with a photon-counting detector.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods<\/jats:title>\n            <jats:p>The institutional review board approved this retrospective study. Twelve women referred for breast cancer screening were included and underwent bilateral spiral B-CT acquired in prone position. Additional sonography was performed in case of dense breast tissue or any B-CT findings. In 3 women, previous mammography was available for comparison. Soft tissue (ST) and high-resolution (HR) images were reconstructed. Two independent radiologists performed separately the readout for subjective image quality and for imaging findings detection. Objective image quality evaluation was performed in consensus and included spatial resolution, contrast resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio. All women were asked to report about positioning comfort and overall comfort during data acquisition.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The major pectoral muscle was included in 15 breast CT scans (62.5%); glandular component was partially missing in 2 (8.3%) of the 24 scanned breasts. A thin \u201cring artifact\u201d was present in all scans but had no influence on image interpretations; no other artifacts were present. Subjective image quality assessment showed excellent agreement between the 2 readers (\u03ba = 1). Three masses were depicted in B-CT and were confirmed as simple cysts in sonography. Additional 5 simple cysts and 2 solid benign lesions were identified only in sonography. A total of 12 calcifications were depicted with a median size of 1.1 mm (interquartile range, 0.7\u20131.7 mm) on HR and 1.4 mm (interquartile range, 1.1\u20131.8 mm) on ST images. Median SNR<jats:sub>gl<\/jats:sub>, SNR<jats:sub>fat<\/jats:sub>, and contrast-to-noise ratio were significantly higher in ST than in HR reconstructions (each, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). A mild discomfort due to positioning of the rib cage on the table was reported by 2 women (16.7%); otherwise, no discomfort was reported.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The new dedicated B-CT equipped with a photon-counting detector provides high-quality images with potential for screening of breast cancer along with minor patient discomfort.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rli.0000000000000552","type":"journal-article","created":{"date-parts":[[2019,3,14]],"date-time":"2019-03-14T17:41:01Z","timestamp":1552585261000},"page":"409-418","source":"Crossref","is-referenced-by-count":63,"title":["Dedicated Breast Computed Tomography With a Photon-Counting Detector"],"prefix":"10.1097","volume":"54","author":[{"given":"Nicole","family":"Berger","sequence":"first","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magda","family":"Marcon","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natalia","family":"Saltybaeva","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Willi A.","family":"Kalender","sequence":"additional","affiliation":[{"name":"Institute of Medical Physics, University of Erlangen-N\u00fcrnberg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hatem","family":"Alkadhi","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Frauenfelder","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Boss","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,3,5]]},"reference":[{"key":"bib1-20230926","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1007\/s10552-010-9585-7","article-title":"A remarkable reduction of breast cancer deaths in screened versus unscreened women: a case-referent study","volume":"21","year":"2010","journal-title":"Cancer Causes Control"},{"key":"bib2-20230926","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1148\/radiol.11110469","article-title":"Swedish two-county trial: impact of mammographic screening on breast cancer mortality during 3 decades","volume":"260","year":"2011","journal-title":"Radiology"},{"key":"bib3-20230926","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1016\/S0140-6736(03)13143-1","article-title":"Mammography service screening and mortality in breast cancer patients: 20-year follow-up before and after introduction of screening","volume":"361","year":"2003","journal-title":"Lancet"},{"key":"bib4-20230926","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1148\/radiol.2251011667","article-title":"Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations","volume":"225","year":"2002","journal-title":"Radiology"},{"key":"bib5-20230926","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1016\/S1470-2045(13)70134-7","article-title":"Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study","volume":"14","year":"2013","journal-title":"Lancet Oncol"},{"key":"bib6-20230926","doi-asserted-by":"crossref","first-page":"2499","DOI":"10.1001\/jama.2014.6095","article-title":"Breast cancer screening using tomosynthesis in combination with digital mammography","volume":"311","year":"2014","journal-title":"JAMA"},{"key":"bib7-20230926","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.1001\/jama.2016.1708","article-title":"Breast cancer screening using tomosynthesis and digital mammography in dense and nondense breasts","volume":"315","year":"2016","journal-title":"JAMA"},{"key":"bib8-20230926","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1148\/radiol.12121373","article-title":"Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program","volume":"267","year":"2013","journal-title":"Radiology"},{"key":"bib9-20230926","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/RLI.0000000000000513","article-title":"Synthetic 2-dimensional mammography can replace digital mammography as an adjunct to wide-angle digital breast tomosynthesis","volume":"54","year":"2019","journal-title":"Invest Radiol"},{"key":"bib10-20230926","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.ejmp.2016.12.004","article-title":"Digital breast tomosynthesis: dose and image quality assessment","volume":"33","year":"2017","journal-title":"Phys Med"},{"key":"bib11-20230926","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1148\/radiol.2213010334","article-title":"Dedicated breast CT: radiation dose and image quality evaluation","volume":"221","year":"2001","journal-title":"Radiology"},{"key":"bib12-20230926","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1148\/radiol.2463070410","article-title":"Dedicated breast CT: initial clinical experience","volume":"246","year":"2008","journal-title":"Radiology"},{"key":"bib13-20230926","doi-asserted-by":"crossref","first-page":"5185","DOI":"10.1007\/s00330-017-4911-z","article-title":"The role of cone-beam breast-CT for breast cancer detection relative to breast density","volume":"27","year":"2017","journal-title":"Eur Radiol"},{"key":"bib14-20230926","doi-asserted-by":"crossref","first-page":"496","DOI":"10.2214\/AJR.08.1017","article-title":"Cone-beam CT for breast imaging: radiation dose, breast coverage, and image quality","volume":"195","year":"2010","journal-title":"Am J Roentgenol"},{"key":"bib15-20230926","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1007\/s00330-016-4459-3","article-title":"Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast","volume":"27","year":"2017","journal-title":"Eur Radiol"},{"key":"bib16-20230926","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00330-011-2169-4","article-title":"High-resolution spiral CT of the breast at very low dose: concept and feasibility considerations","volume":"22","year":"2012","journal-title":"Eur Radiol"},{"key":"bib17-20230926","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1097\/RLI.0000000000000485","article-title":"Photon counting computed tomography with dedicated sharp convolution Kernels tapping the potential of a new technology for stent imaging","volume":"53","year":"2018","journal-title":"Invest Radiol"},{"key":"bib18-20230926","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1097\/RLI.0000000000000488","article-title":"150-\u03bcm spatial resolution using photon-counting detector computed tomography technology: technical performance and first patient images","volume":"53","year":"2018","journal-title":"Invest Radiol"},{"key":"bib19-20230926","first-page":"CD002942","article-title":"Interventions for relieving the pain and discomfort of screening mammography","year":"2008","journal-title":"Cochrane Database Syst Rev"},{"key":"bib22-20230926","doi-asserted-by":"crossref","first-page":"3731","DOI":"10.1007\/s00330-018-5376-4","article-title":"Contrast-enhanced cone-beam breast-CT (CBBCT): clinical performance compared to mammography and MRI","volume":"28","year":"2018","journal-title":"Eur Radiol"},{"key":"bib23-20230926","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1016\/j.ejrad.2015.11.029","article-title":"The utility of breast cone-beam computed tomography, ultrasound, and digital mammography for detecting malignant breast tumors: a prospective study with 212 patients","volume":"85","year":"2016","journal-title":"Eur J Radiol"},{"key":"bib24-20230926","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1097\/RLI.0000000000000251","article-title":"Human imaging with photon counting-based computed tomography at clinical dose levels: contrast-to-noise ratio and cadaver studies","volume":"51","year":"2016","journal-title":"Invest Radiol"},{"key":"bib25-20230926","doi-asserted-by":"crossref","first-page":"2730","DOI":"10.1118\/1.2742498","article-title":"Physical characteristics of five clinical systems for digital mammography","volume":"34","year":"2007","journal-title":"Med Phys"},{"key":"bib26-20230926","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.clinimag.2016.11.011","article-title":"Review of clinical studies and first clinical experiences with a commercially available cone-beam breast CT in Europe","volume":"42","year":"2017","journal-title":"Clin Imaging"},{"key":"bib27-20230926","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1148\/radiology.203.2.9114083","article-title":"Clinical importance of unilaterally enlarging lymph nodes on otherwise normal mammograms","volume":"203","year":"1997","journal-title":"Radiology"},{"key":"bib28-20230926","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1148\/radiol.2017171218","article-title":"Supplemental screening breast US in women with negative mammographic findings: effect of routine axillary scanning","volume":"286","year":"2018","journal-title":"Radiology"},{"key":"bib29-20230926","first-page":"CD001877","article-title":"Screening for breast cancer with mammography","year":"2011","journal-title":"Cochrane Database Syst Rev"},{"key":"bib30-20230926","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1016\/S0140-6736(02)08020-0","article-title":"Long-term effects of mammography screening: updated overview of the Swedish randomised trials","volume":"359","year":"2002","journal-title":"Lancet"},{"key":"bib31-20230926","doi-asserted-by":"crossref","first-page":"1778","DOI":"10.1016\/S0140-6736(12)61611-0","article-title":"The benefits and harms of breast cancer screening: an independent review","volume":"380","year":"2012","journal-title":"Lancet"},{"key":"bib32-20230926","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.ejrad.2017.12.003","article-title":"Contrast-enhanced cone-beam breast-CT: analysis of optimal acquisition time for discrimination of breast lesion malignancy","volume":"99","year":"2018","journal-title":"Eur J Radiol"},{"key":"bib33-20230926","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1097\/RLI.0000000000000228","article-title":"Gadolinium deposition in humans when did we learn that gadolinium was deposited in vivo?","volume":"51","year":"2016","journal-title":"Invest Radiol"},{"key":"bib34-20230926","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1148\/rg.246045065","article-title":"Artifacts in CT: recognition and avoidance","volume":"24","year":"2004","journal-title":"Radiographics"},{"key":"bib35-20230926","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1016\/j.acra.2016.11.017","article-title":"Artifacts caused by breast tissue markers in a dedicated cone-beam breast CT in comparison to full-field digital mammography","volume":"24","year":"2017","journal-title":"Acad Radiol"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004424-201907000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T18:13:37Z","timestamp":1695752017000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004424-201907000-00004"}},"subtitle":["Initial Results of Clinical In Vivo Imaging"],"short-title":[],"issued":{"date-parts":[[2019,3,5]]},"references-count":33,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000552","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2019,3,5]]}}}