{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T05:50:34Z","timestamp":1775713834238,"version":"3.50.1"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>Balanced steady-state free precession-based quiescent-interval slice-selective (bSSFP QISS) magnetic resonance angiography (MRA) is accurate for the noncontrast evaluation of peripheral arterial disease (PAD); however, drawbacks include the need for breath-holding when imaging the abdomen and pelvis, and sensitivity to off-resonance artifacts. The purpose of this study was to evaluate the image quality and diagnostic accuracy in the pelvis and abdomen of free-breathing fast low-angle shot-based QISS (FLASH QISS) techniques in comparison to bSSFP QISS in patients with PAD, using computed tomographic angiography as the reference.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>Twenty-seven patients (69 \u00b1 10 years, 17 men) with PAD were enrolled in this institutional review board\u2013approved, Health Insurance Portability and Accountability Act\u2013compliant prospective study between April and December 2018. Patients underwent noncontrast MRA using standard bSSFP QISS and prototype free-breathing radial-FLASH and Cartesian-FLASH QISS at 3 T. A subset of patients (n = 22) also underwent computed tomographic angiography as the reference standard. Nine arterial segments per patient were evaluated spanning the abdomen, pelvis, and upper thigh regions. Objective (signal intensity ratio and relative standard deviation) and subjective image quality (4-point scale) and stenosis (&gt;50%) were evaluated by 2 readers and compared using one-way analysis of variance, Wilcoxon, and McNemar tests, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A total of 179 vascular segments were available for analysis by all QISS techniques. No significant difference was observed among bSSFP, radial-FLASH, and Cartesian-FLASH QISS techniques in signal intensity ratio (<jats:italic toggle=\"yes\">P<\/jats:italic>= 0.428) and relative standard deviation (<jats:italic toggle=\"yes\">P<\/jats:italic>= 0.220). Radial-FLASH QISS demonstrated the best image quality (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt; 0.0001) and the highest interreader agreement (\u03ba = 0.721). The sensitivity values of bSSFP, radial-FLASH, and Cartesian-FLASH QISS for the detection of greater than 50% stenosis were 76.0%, 84.0%, and 80.0%, respectively, whereas specificity values were 97.6%, 94.0%, and 92.8%, respectively. Moreover, FLASH QISS consistently reduced off-resonance artifacts compared with bSSFP QISS.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Free-breathing FLASH QISS MRA techniques provide improved image quality and sensitivity, high specificity, and reduced off-resonance artifacts for vascular stenosis detection in the abdomen and pelvis.<\/jats:p><\/jats:sec>","DOI":"10.1097\/rli.0000000000000592","type":"journal-article","created":{"date-parts":[[2019,7,11]],"date-time":"2019-07-11T05:44:49Z","timestamp":1562823889000},"page":"752-756","source":"Crossref","is-referenced-by-count":9,"title":["Free-Breathing Fast Low-Angle Shot Quiescent-Interval Slice-Selective Magnetic Resonance Angiography for Improved Detection of Vascular Stenoses in the Pelvis and Abdomen"],"prefix":"10.1097","volume":"54","author":[{"given":"Akos","family":"Varga-Szemes","sequence":"first","affiliation":[{"name":"Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emily A.","family":"Aherne","sequence":"additional","affiliation":[{"name":"Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"U. Joseph","family":"Schoepf","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas M.","family":"Todoran","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ioannis","family":"Koktzoglou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert R.","family":"Edelman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2019,7,10]]},"reference":[{"key":"bib1-20230926","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1161\/01.CIR.0000137913.26087.F0","article-title":"Prevalence of and risk factors for peripheral arterial disease in the United States: results from the National Health and Nutrition Examination Survey, 1999\u20132000","volume":"110","year":"2004","journal-title":"Circulation"},{"key":"bib2-20230926","first-page":"81","article-title":"Inter-society consensus for the management of peripheral arterial disease","volume":"26","year":"2007","journal-title":"Int Angiol"},{"key":"bib3-20230926","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.1016\/j.jacc.2013.01.004","article-title":"Management of patients with peripheral artery disease (compilation of 2005 and 2011 ACCF\/AHA Guideline Recommendations): a report of the American College of Cardiology Foundation\/American Heart Association Task Force on Practice Guidelines","volume":"61","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"bib4-20230926","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1148\/radiol.2312020920","article-title":"Infrarenal aortic and lower-extremity arterial disease: diagnostic performance of multi-detector row CT angiography","volume":"231","year":"2004","journal-title":"Radiology"},{"key":"bib5-20230926","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/RLI.0000000000000216","article-title":"Dual-energy computed tomography angiography of the lower extremity runoff: impact of noise-optimized virtual monochromatic imaging on image quality and diagnostic accuracy","volume":"51","year":"2016","journal-title":"Invest Radiol"},{"key":"bib6-20230926","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1148\/radiol.2412050781","article-title":"Vessel wall calcifications at multi-detector row CT angiography in patients with peripheral arterial disease: effect on clinical utility and clinical predictors","volume":"241","year":"2006","journal-title":"Radiology"},{"key":"bib7-20230926","first-page":"313","article-title":"Peripheral arterial disease and kidney failure: a frequent association","volume":"32","year":"2012","journal-title":"Nefrologia"},{"key":"bib8-20230926","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1148\/radiol.13122276","article-title":"Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material: risk stratification by using estimated glomerular filtration rate","volume":"268","year":"2013","journal-title":"Radiology"},{"key":"bib9-20230926","doi-asserted-by":"crossref","first-page":"325","DOI":"10.7326\/0003-4819-153-5-201009070-00007","article-title":"Meta-analysis: accuracy of contrast-enhanced magnetic resonance angiography for assessing steno-occlusions in peripheral arterial disease","volume":"153","year":"2010","journal-title":"Ann Intern Med"},{"key":"bib10-20230926","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1148\/radiol.2423061640","article-title":"Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis","volume":"242","year":"2007","journal-title":"Radiology"},{"key":"bib11-20230926","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1016\/S1474-4422(17)30158-8","article-title":"Gadolinium deposition in the brain: summary of evidence and recommendations","volume":"16","year":"2017","journal-title":"Lancet Neurol"},{"key":"bib12-20230926","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1002\/mrm.22287","article-title":"Quiescent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: technical considerations and clinical feasibility","volume":"63","year":"2010","journal-title":"Magn Reson Med"},{"key":"bib13-20230926","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.1002\/jmri.24324","article-title":"Nonenhanced ECG-gated quiescent-interval single shot MRA: image quality and stenosis assessment at 3 tesla compared with contrast-enhanced MRA and digital subtraction angiography","volume":"39","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"bib14-20230926","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1148\/radiol.11101336","article-title":"Evaluation of peripheral arterial disease with nonenhanced quiescent-interval single-shot MR angiography","volume":"260","year":"2011","journal-title":"Radiology"},{"key":"bib15-20230926","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.crad.2011.10.014","article-title":"Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: comparison with contrast-enhanced MRA","volume":"67","year":"2012","journal-title":"Clin Radiol"},{"key":"bib16-20230926","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.jcmg.2016.09.030","article-title":"Accuracy of noncontrast quiescent-interval single-shot lower extremity MR angiography versus CT angiography for diagnosis of peripheral artery disease: comparison with digital subtraction angiography","volume":"10","year":"2017","journal-title":"JACC Cardiovasc Imaging"},{"key":"bib17-20230926","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1186\/s12968-016-0294-6","article-title":"The diagnostic value of non-contrast enhanced quiescent interval single shot (QISS) magnetic resonance angiography at 3T for lower extremity peripheral arterial disease, in comparison to CT angiography","volume":"18","year":"2016","journal-title":"J Cardiovasc Magn Reson"},{"key":"bib18-20230926","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1002\/jmri.20969","article-title":"Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters","volume":"26","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"bib19-20230926","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1007\/s10554-015-0612-3","article-title":"Nonenhanced peripheral MR-angiography (MRA) at 3 Tesla: evaluation of quiescent-interval single-shot MRA in patients undergoing digital subtraction angiography","volume":"31","year":"2015","journal-title":"Int J Cardiovasc Imaging"},{"key":"bib20-20230926","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1093\/ije\/25.6.1172","article-title":"Incidence, natural history and cardiovascular events in symptomatic and asymptomatic peripheral arterial disease in the general population","volume":"25","year":"1996","journal-title":"Int J Epidemiol"},{"key":"bib21-20230926","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1002\/mrm.26715","article-title":"Super-resolution intracranial quiescent interval slice-selective magnetic resonance angiography","volume":"79","year":"2018","journal-title":"Magn Reson Med"},{"key":"bib22-20230926","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1186\/s12968-015-0205-2","article-title":"Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla","volume":"17","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"key":"bib23-20230926","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.crad.2017.12.003","article-title":"Advances in non-contrast quiescent-interval slice-selective (QISS) magnetic resonance angiography","volume":"74","year":"2019","journal-title":"Clin Radiol"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000592","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,20]],"date-time":"2024-07-20T21:30:08Z","timestamp":1721511008000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000592"}},"subtitle":["Technical Development"],"short-title":[],"issued":{"date-parts":[[2019,7,10]]},"references-count":23,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000592","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2019,7,10]]}}}