{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T04:20:21Z","timestamp":1777004421810,"version":"3.51.4"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Iodinated contrast media (CM) are utilized in approximately 40% of the 300 million computed tomography (CT) scans undertaken annually. This review focuses on the physicochemical properties and safety of iodinated CM, and the development of new x-ray CM, and it explores methods to optimize CT scanning parameters. It concludes that good x-ray CM should have high structural stability, hydrophilicity, and CT attenuation; low viscosity, osmolality, and protein binding; no metabolism and tissue accumulation; and a complete elimination.<\/jats:p>","DOI":"10.1097\/rli.0000000000000686","type":"journal-article","created":{"date-parts":[[2020,5,26]],"date-time":"2020-05-26T03:56:52Z","timestamp":1590465412000},"page":"598-600","source":"Crossref","is-referenced-by-count":11,"title":["Future of Diagnostic Computed Tomography"],"prefix":"10.1097","volume":"55","author":[{"given":"Imran","family":"Shahid","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric","family":"Lancelot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre","family":"Desch\u00e9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,5,26]]},"reference":[{"key":"bib1-20230926","first-page":"159","article-title":"The history of Lipiodol (1901\u20131994) or how a medication may evolve with the times","volume":"42","year":"1995","journal-title":"Rev Hist Pharm (Paris)"},{"key":"bib3-20230926","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1148\/rg.313105079","article-title":"Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls","volume":"31","year":"2011","journal-title":"Radiographics"},{"key":"bib4-20230926","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1097\/RLI.0000000000000696","article-title":"Developments in x-ray contrast media and the potential impact on computed tomography","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib5-20230926","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1097\/RLI.0000000000000611","article-title":"Risk of hypersensitivity reactions to iopromide after intra-arterial versus intravenous administration: a nested case-control analysis of 133,331 patients","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib6-20230926","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1177\/0284185113504753","article-title":"Safety and tolerability of iopromide intravascular use: a pooled analysis of three non-interventional studies in 132,012 patients","volume":"55","year":"2014","journal-title":"Acta Radiol"},{"key":"bib7-20230926","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1016\/S0140-6736(17)30057-0","article-title":"Prophylactic hydration to protect renal function from intravascular iodinated contrast material in patients at high risk of contrast-induced nephropathy (AMACING): a prospective, randomised, phase 3, controlled, open-label, non-inferiority trial","volume":"389","year":"2017","journal-title":"Lancet"},{"key":"bib8-20230926","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.ejrad.2019.03.008","article-title":"Nephrotoxicity of iodinated contrast media: from pathophysiology to prevention strategies","volume":"116","year":"2019","journal-title":"Eur J Radiol"},{"key":"bib9-20230926","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/j.jcin.2009.05.002","article-title":"The relative renal safety of iodixanol compared with low-osmolar contrast media a meta-analysis of randomized controlled trials","volume":"2","year":"2009","journal-title":"JACC Cardiovasc Interv"},{"key":"bib10-20230926","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1148\/radiol.2501080833","article-title":"Nephrotoxicity of iso-osmolar iodixanol compared with nonionic low-osmolar contrast media: meta-analysis of randomized controlled trials","volume":"250","year":"2009","journal-title":"Radiology"},{"key":"bib11-20230926","doi-asserted-by":"crossref","first-page":"2845","DOI":"10.1007\/s00330-017-5246-5","article-title":"Post-contrast acute kidney injury \u2013 part 1: definition, clinical features, incidence, role of contrast medium and risk factors. Recommendations for updated ESUR contrast medium safety committee guidelines","volume":"28","year":"2018","journal-title":"Eur Radiol"},{"key":"bib13-20230926","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1097\/00004424-199401000-00015","article-title":"Physicochemical parameters of x-ray contrast media","volume":"29","year":"1994","journal-title":"Invest Radiol"},{"key":"bib14-20230926","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/0720-048X(94)00579-2","article-title":"The acute effect of ioversol on kidney function: role of endothelin","volume":"19","year":"1995","journal-title":"Eur J Radiol"},{"key":"bib15-20230926","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1111\/ced.13990","article-title":"Contrast media and cutaneous reactions. Part 1. Immediate hypersensitivity reactions to contrast media and gadolinium deposition","volume":"44","year":"2019","journal-title":"Clin Exp Dermatol"},{"key":"bib16-20230926","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.eclinm.2018.07.002","article-title":"Immediate hypersensitivity to contrast agents: the French 5-year CIRTACI study","volume":"1","year":"2018","journal-title":"EClinicalMedicine"},{"key":"bib17-20230926","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/RLI.0000000000000620","article-title":"Safety analysis of iobitridol as a nonionic contrast medium a postmarketing multicenter surveillance study with 94,960 patients almost 20 years after introduction","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib18-20230926","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1007\/s00330-009-1698-6","article-title":"Are there any differences in acute adverse reactions among five low-osmolar non-ionic iodinated contrast media?","volume":"20","year":"2010","journal-title":"Eur Radiol"},{"key":"bib19-20230926","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.3346\/jkms.2013.28.12.1703","article-title":"Comparison of the safety of seven iodinated contrast media","volume":"28","year":"2013","journal-title":"J Korean Med Sci"},{"key":"bib20-20230926","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1148\/radiol.2019190829","article-title":"Relationship between lower dose and injection speed of iodinated contrast material for CT and acute hypersensitivity reactions: an observational study","volume":"293","year":"2019","journal-title":"Radiology"},{"key":"bib21-20230926","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1148\/radiol.2019192094","article-title":"Use of intravenous iodinated contrast media in patients with kidney disease: consensus statements from the American College of Radiology and the National Kidney Foundation","volume":"294","year":"2020","journal-title":"Radiology"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000686","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T18:19:39Z","timestamp":1695752379000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000686"}},"subtitle":["An Update on Physicochemical Properties, Safety, and Development of X-ray Contrast Media"],"short-title":[],"issued":{"date-parts":[[2020,5,26]]},"references-count":19,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000686","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2020,5,26]]}}}