{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:38:06Z","timestamp":1793727486371,"version":"4.6.1"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2022,1,13]],"date-time":"2022-01-13T00:00:00Z","timestamp":1642032000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The diagnostic performance of coronary computed tomography angiography is known to be negatively affected by the presence of severely calcified plaques in the coronary arteries. In this article, the performance of a novel image reconstruction algorithm (PureLumen) based on spectral CT data of a first-generation dual-source photon-counting detector computed tomography (PCD-CT) system was assessed in a phantom study. PureLumen tries to remove only the calcified contributions from the image while leaving the rest unmodified.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods<\/jats:title>\n            <jats:p>The study uses 2 iodine contrast filled vessel phantoms (diameter 4 mm) filled with different concentrations of iodine and equipped with calcified stenosis inserts. Each phantom features 2 separate calcified lesions of 25% and 50% percentage diameter stenosis (PDS) size. The vessel phantoms were mounted inside an anthropomorphic thorax phantom attached to an artificial motion device, simulating realistic cardiac motion at heart rates between 50 beats per minute and 100 beats per minute. Acquisitions were performed using a prospectively electrocardiogram triggered dual-source sequence mode on a PCD-CT system (NAEOTOM Alpha, Siemens Healthineers). Images were reconstructed at 80% of the RR interval with virtual monoenergetic images (Mono) and with additional calcium-removal (PureLumen), both at 65 keV. PureLumen is based on a spectral base material decomposition into iodine and calcium, which aims to reconstruct images without calcium contributions, while leaving all other material contribution unchanged. Stenosis grade was assessed individually for each vessel insert in all reconstructed image series by 2 readers.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The measured median PDS values for the 50% lesion were 56.0% (52.0%, 57.0%) for the Mono case and 50.0% (48.5%, 51.0%) for PureLumen. The 25% lesion median PDS values were 36.0% (29.5%, 39.5%) for Mono and 31.5% (30.5%, 34.0%) for PureLumen. Both lesion sizes demonstrate a significant difference between Mono and PureLumen in their result (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05) with PureLumen median values being closer to the actual true stenosis size for the 50% and 25% lesion. A visual assessment of the image quality depending on the heart rate yielded good image quality up to a heart rate of 80 beats per minute in the PureLumen case.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>This phantom study shows that a novel calcium-removal image reconstruction algorithm (PureLumen) using a first-generation dual-source PCD-CT effectively decreases blooming artifacts caused by heavily calcified plaques and improves image interpretability. It also shows that PureLumen retains its performance in the presence of motion with simulated heart rates up to 80 beats per minute. Future in vivo clinical studies are needed to confirm the benefits of this type of reconstruction in terms of coronary computed tomography angiography quality and accuracy.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rli.0000000000000853","type":"journal-article","created":{"date-parts":[[2022,1,13]],"date-time":"2022-01-13T15:03:51Z","timestamp":1642086231000},"page":"399-405","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":103,"title":["Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm"],"prefix":"10.1097","volume":"57","author":[{"given":"Thomas","family":"Allmendinger","sequence":"first","affiliation":[{"name":"Siemens Healthcare GmbH, Forchheim"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tristan","family":"Nowak","sequence":"additional","affiliation":[{"name":"Siemens Healthcare GmbH, Forchheim"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Flohr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ernst","family":"Klotz","sequence":"additional","affiliation":[{"name":"Siemens Healthcare GmbH, Forchheim"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junia","family":"Hagenauer","sequence":"additional","affiliation":[{"name":"Siemens Healthcare GmbH, Forchheim"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hatem","family":"Alkadhi","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,1,13]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"2135","DOI":"10.1016\/j.jacc.2008.08.058","article-title":"Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study","volume":"52","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"1724","DOI":"10.1016\/j.jacc.2008.07.031","article-title":"Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (assessment by coronary computed tomographic angiography of individuals undergoing invasive coronary angiography) trial","volume":"52","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1016\/j.jacc.2010.10.011","article-title":"Prognostic value of cardiac computed tomography angiography: a systematic review and meta-analysis","volume":"57","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"1676","DOI":"10.2214\/AJR.07.4026","article-title":"Accuracy of MDCT in assessing the degree of stenosis caused by calcified coronary artery plaques","volume":"191","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.jacc.2005.05.056","article-title":"Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography","volume":"46","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"2638","DOI":"10.1161\/01.CIR.0000145614.07427.9F","article-title":"Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis","volume":"110","year":"2004","journal-title":"Circulation"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1148\/radiol.11110537","article-title":"Coronary artery stenoses: accuracy of 64-detector row CT angiography in segments with mild, moderate, or severe calcification\u2014a subanalysis of the CORE-64 trial","volume":"261","year":"2011","journal-title":"Radiology"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"2064","DOI":"10.1148\/rg.2016160079","article-title":"Artifacts at cardiac CT: physics and solutions","volume":"36","year":"2016","journal-title":"Radiographics"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1148\/radiol.11103574","article-title":"Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction","volume":"260","year":"2011","journal-title":"Radiology"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1097\/RLI.0000000000000668","article-title":"The future of computed tomography: personalized, functional, and precise","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","article-title":"Photon-counting CT review","volume":"79","year":"2020","journal-title":"Phys Med"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon-counting CT: technical principles and clinical prospects","volume":"289","year":"2018","journal-title":"Radiology"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1109\/TRPMS.2020.3020212","article-title":"Photon counting CT: clinical applications and future developments","volume":"5","year":"2021","journal-title":"IEEE Trans Radiat Plasma Med Sci"},{"key":"bib14-20250802","article-title":"High-pitch photon-counting detector computed tomography angiography of the aorta: intraindividual comparison to energy-integrating detector computed tomography at equal radiation dose","year":"2021","journal-title":"Invest Radiol"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"6621","DOI":"10.1007\/s00330-021-07780-6","article-title":"Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens","volume":"31","year":"2021","journal-title":"Eur Radiol"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"1708","DOI":"10.3390\/diagnostics11091708","article-title":"Coronary calcium scoring with first generation dual-source photon-counting CT-first evidence from phantom and in-vivo scans","volume":"11","year":"2021","journal-title":"Diagnostics (Basel)"},{"key":"bib17-20250802","article-title":"First performance evaluation of an artificial intelligence-based computer-aided detection system for pulmonary nodule evaluation in dual-source photon-counting detector CT at different low-dose levels","year":"2021","journal-title":"Invest Radiol"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1097\/RLI.0000000000000773","article-title":"Photon-counting multienergy computed tomography with spectrally optimized contrast media for plaque removal and stenosis assessment","volume":"56","year":"2021","journal-title":"Invest Radiol"},{"key":"bib19-20250802","article-title":"Contrast-enhanced abdominal CT with clinical photon-counting detector CT: assessment of image quality and comparison with energy-integrating detector CT","year":"2021","journal-title":"Acad Radiol"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1097\/RLI.0000000000000787","article-title":"Photon-counting computed tomography for coronary stent imaging: in vitro evaluation of 28 coronary stents","volume":"56","year":"2021","journal-title":"Invest Radiol"},{"key":"bib21-20250802","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1007\/s00330-006-0517-6","article-title":"Material differentiation by dual energy CT: initial experience","volume":"17","year":"2007","journal-title":"Eur Radiol"},{"key":"bib22-20250802","first-page":"2058460117717765","article-title":"Dual-energy computed tomography angiography: virtual calcified plaque subtraction in a vascular phantom","volume":"6","year":"2017","journal-title":"Acta Radiol Open"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1148\/radiol.2483071576","article-title":"Calcified vascular plaque specimens: assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantom","volume":"249","year":"2008","journal-title":"Radiology"},{"key":"bib24-20250802","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1148\/radiology.216.2.r00au19457","article-title":"In-plane coronary arterial motion velocity: measurement with electron-beam CT","volume":"216","year":"2000","journal-title":"Radiology"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1097\/RLI.0000000000000391","article-title":"Modified dual-energy algorithm for calcified plaque removal: evaluation in carotid computed tomography angiography and comparison with digital subtraction angiography","volume":"52","year":"2017","journal-title":"Invest Radiol"},{"key":"bib26-20250802","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1088\/0031-9155\/21\/5\/002","article-title":"Energy-selective reconstructions in x-ray computerized tomography","volume":"21","year":"1976","journal-title":"Phys Med Biol"},{"key":"bib27-20250802","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1118\/1.595025","article-title":"Generalized image combinations in dual KVP digital radiography","volume":"8","year":"1981","journal-title":"Med Phys"},{"issue":"suppl 5","key":"bib28-20250802","first-page":"S9","article-title":"Dual-energy CT-based monochromatic imaging","volume":"199","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1097\/RLI.0000000000000060","article-title":"Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media","volume":"49","year":"2014","journal-title":"Invest Radiol"},{"key":"bib30-20250802","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.jcmg.2010.10.011","article-title":"Quantification of coronary arterial stenoses by multidetector CT angiography in comparison with conventional angiography methods, caveats, and implications","volume":"4","year":"2011","journal-title":"JACC Cardiovasc Imaging"},{"key":"bib32-20250802","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.jcct.2016.04.005","article-title":"CAD-RADS(TM) coronary artery disease - reporting and data system. An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Radiology (ACR) and the north American Society for Cardiovascular Imaging (NASCI). Endorsed by the American College of Cardiology","volume":"10","year":"2016","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"bib33-20250802","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1148\/radiol.2017172181","article-title":"Central core laboratory versus site interpretation of coronary CT angiography: agreement and association with cardiovascular events in the PROMISE trial","volume":"287","year":"2018","journal-title":"Radiology"},{"key":"bib34-20250802","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.jcct.2016.10.002","article-title":"SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee: endorsed by the North American Society for Cardiovascular Imaging (NASCI)","volume":"10","year":"2016","journal-title":"J Cardiovasc Comput Tomogr"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000853","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T19:08:47Z","timestamp":1754161727000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000853"}},"subtitle":["Assessment Using a Cardiac Motion Phantom"],"short-title":[],"issued":{"date-parts":[[2022,1,13]]},"references-count":33,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000853","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2022,1,13]]}}}