{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T11:32:43Z","timestamp":1794051163601,"version":"4.8.0"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>After a decade of preclinical testing, photon-counting computed tomography (PCCT) has now entered daily routine, enabling radiologists to start investigating thoracic disorders in unprecedented conditions. The improved spatial resolution of the ultra-high-resolution (UHR) scanning mode is a major step for the analysis of bronchopulmonary disorders, making abnormalities at the level of small anatomical structures such as secondary pulmonary lobules accessible to radiologists. Distal divisions of pulmonary and systemic vessels also benefit from UHR protocols as alterations of lung microcirculation were previously excluded from confident analysis with energy-integrating detector CT. Although noncontrast chest CT examinations were the initial target of UHR protocols, the clinical value of this mode is also applicable to chest CT angiographic examinations with improved morphological evaluation and higher-quality lung perfusion imaging. The clinical benefits of UHR have been evaluated in initial studies, allowing radiologists to foresee the field of future applications, all combining high diagnostic value and radiation dose reduction. The purpose of this article is to highlight the technological information relevant to daily practice and to review the current clinical applications in the field of chest imaging.<\/jats:p>","DOI":"10.1097\/rli.0000000000000968","type":"journal-article","created":{"date-parts":[[2023,3,10]],"date-time":"2023-03-10T14:00:07Z","timestamp":1678456807000},"page":"482-487","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":63,"title":["Ultra-High-Resolution Photon-Counting CT Imaging of the Chest"],"prefix":"10.1097","volume":"58","author":[{"given":"Martine","family":"Remy-Jardin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antoine","family":"Hutt","sequence":"additional","affiliation":[{"name":"Department of Thoracic Imaging, Heart and Lung Institute, University Hospital Center of Lille"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Flohr","sequence":"additional","affiliation":[{"name":"Department of Computed Tomography Research and Development, Siemens Healthineers, Forchheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Baptiste","family":"Faivre","sequence":"additional","affiliation":[{"name":"Department of Thoracic Imaging, Heart and Lung Institute, University Hospital Center of Lille"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Felloni","sequence":"additional","affiliation":[{"name":"Department of Thoracic Imaging, Heart and Lung Institute, University Hospital Center of Lille"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suonita","family":"Khung","sequence":"additional","affiliation":[{"name":"Department of Thoracic Imaging, Heart and Lung Institute, University Hospital Center of Lille"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacques","family":"Remy","sequence":"additional","affiliation":[{"name":"Department of Thoracic Imaging, Heart and Lung Institute, University Hospital Center of Lille"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,3,11]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon counting CT: technical principles and clinical prospects","volume":"289","year":"2018","journal-title":"Radiology"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","article-title":"Photon-counting CT review","volume":"79","year":"2020","journal-title":"Phys Med"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1148\/radiol.212579","article-title":"First clinical photon-counting detector CT system: technical evaluation","volume":"303","year":"2022","journal-title":"Radiology"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1097\/RTI.0000000000000569","article-title":"Review of technical advancements and clinical applications of photon-counting computed tomography in imaging of the thorax","volume":"36","year":"2021","journal-title":"J Thorac Imaging"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"5757","DOI":"10.3390\/jcm10245757","article-title":"Spectral photon-counting CT technology in chest imaging","volume":"10","year":"2021","journal-title":"J Clin Med"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"17386","DOI":"10.1038\/s41598-018-35888-1","article-title":"Evaluation of a preclinical photon-counting CT prototype for pulmonary imaging","volume":"8","year":"2018","journal-title":"Sci Rep"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1097\/RCT.0000000000000917","article-title":"Prototype ultrahigh-resolution computed tomography for chest imaging: initial human experience","volume":"43","year":"2019","journal-title":"J Comput Assist Tomogr"},{"key":"bib8-20250802","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.diii.2021.01.001","article-title":"Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system","volume":"102","year":"2021","journal-title":"Diagn Interv Imaging"},{"key":"bib9-20250802","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1148\/radiol.2017162587","article-title":"Feasibility of dose-reduced chest CT with photon-counting detectors: initial results in humans","volume":"285","year":"2017","journal-title":"Radiology"},{"key":"bib10-20250802","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1097\/RLI.0000000000000488","article-title":"150-\u03bcm spatial resolution using photon-counting detector computed tomography technology: technical performance and first patient images","volume":"53","year":"2018","journal-title":"Invest Radiol"},{"key":"bib11-20250802","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/RLI.0000000000000463","article-title":"Dose efficiency of quarter-millimeter photon-counting computed tomography: first-in-human results","volume":"53","year":"2018","journal-title":"Invest Radiol"},{"key":"bib12-20250802","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/RLI.0000000000000524","article-title":"High-resolution chest computed tomography imaging of the lungs: impact of 1024 matrix reconstruction and photon-counting detector computed tomography","volume":"54","year":"2019","journal-title":"Invest Radiol"},{"key":"bib13-20250802","doi-asserted-by":"crossref","first-page":"109614","DOI":"10.1016\/j.ejrad.2021.109614","article-title":"Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience","volume":"137","year":"2021","journal-title":"Eur J Radiol"},{"key":"bib14-20250802","doi-asserted-by":"crossref","first-page":"205019","DOI":"10.1088\/1361-6560\/ac155e","article-title":"Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience","volume":"66","year":"2021","journal-title":"Phys Med Biol"},{"key":"bib15-20250802","doi-asserted-by":"crossref","first-page":"e18","DOI":"10.1164\/rccm.202202-0399ST","article-title":"Idiopathic pulmonary fibrosis (an Update) and progressive pulmonary fibrosis in adults: an official ATS\/ERS\/JRS\/ALAT clinical practice guideline","volume":"205","year":"2022","journal-title":"Am J Respir Crit Care Med"},{"key":"bib16-20250802","doi-asserted-by":"crossref","first-page":"e36","DOI":"10.1164\/rccm.202005-2032ST","article-title":"Diagnosis of hypersensitivity pneumonitis in adults. An official ATS\/JRS\/ALAT clinical practice guideline","volume":"202","year":"2020","journal-title":"Am J Respir Crit Care Med"},{"key":"bib18-20250802","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.3390\/diagnostics12061441","article-title":"Low-dose-high-resolution photon-counting CT of the lung: radiation dose and image quality in the clinical routine","volume":"12","year":"2022","journal-title":"Diagnostics (Basel)"},{"key":"bib19-20250802","doi-asserted-by":"crossref","first-page":"522","DOI":"10.3390\/diagnostics12020522","article-title":"Quantum iterative reconstruction for low-dose ultra-high-resolution photon-counting detector CT of the lung","volume":"12","year":"2022","journal-title":"Diagnostics (Basel)"},{"key":"bib20-20250802","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1097\/RLI.0000000000000888","article-title":"Estimating the clinical impact of photon-counting-detector CT in diagnosing usual interstitial pneumonia","volume":"57","year":"2022","journal-title":"Invest Radiol"},{"key":"bib21-20250802","article-title":"Detection of post-COVID-19 lung abnormalities: photon-counting CT versus same-day energy-integrating detector CT","year":"2022","journal-title":"Radiology"},{"key":"bib22-20250802","doi-asserted-by":"crossref","first-page":"20200944","DOI":"10.1259\/bjr.20200944","article-title":"The evolution of computer-based analysis of high-resolution CT of the chest in patients with IPF","volume":"95","year":"2022","journal-title":"Br J Radiol"},{"key":"bib23-20250802","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.3904\/kjim.2021.124","article-title":"Recent advances in airway imaging using micro-computed tomography and computed tomography for chronic obstructive pulmonary disease","volume":"36","year":"2021","journal-title":"Korean J Intern Med"},{"key":"bib24-20250802","first-page":"101323Q","article-title":"Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon counting detector CT system","volume":"10132","year":"2017","journal-title":"Proc SPIE Int Soc Opt Eng"},{"key":"bib25-20250802","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/RLI.0000000000000814","article-title":"First performance evaluation of an artificial intelligence-based computer-aided detection system for pulmonary nodule evaluation in dual-source photon-counting detector CT at different low-dose levels","volume":"57","year":"2022","journal-title":"Invest Radiol"},{"key":"bib27-20250802","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1097\/RLI.0000000000000668","article-title":"The future of computed tomography: personalized, functional, and precise","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib28-20250802","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1097\/RLI.0000000000000848","article-title":"Impact of contrast enhancement and virtual monoenergetic image energy levels on emphysema quantification: experience with photon-counting detector computed tomography","volume":"57","year":"2022","journal-title":"Invest Radiol"},{"key":"bib29-20250802","doi-asserted-by":"crossref","first-page":"20211367","DOI":"10.1259\/bjr.20211367","article-title":"Performance of virtual non-contrast images generated on clinical photon-counting detector CT for emphysema quantification: proof of concept","volume":"95","year":"2022","journal-title":"Br J Radiol"},{"key":"bib30-20250802","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.3390\/tomography8030119","article-title":"Image quality and radiation dose of contrast-enhanced chest-CT acquired on a clinical photon-counting detector CT vs. second-generation dual-source CT in an oncologic cohort: preliminary results","volume":"8","year":"2022","journal-title":"Tomography"},{"key":"bib31-20250802","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1148\/radiol.2021210600","article-title":"Dual-energy CT perfusion of invasive tumor front in non\u2013small cell lung cancers","volume":"302","year":"2022","journal-title":"Radiology"},{"key":"bib32-20250802","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1148\/radiol.2020201911","article-title":"Lung adenocarcinoma at CT with 0.25-mm section thickness and a 2048 matrix: high-spatial-resolution imaging for predicting invasiveness","volume":"297","year":"2020","journal-title":"Radiology"},{"key":"bib33-20250802","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1097\/RLI.0000000000000822","article-title":"Personalized chest computed tomography: minimum diagnostic radiation dose levels for the detection of fibrosis, nodules, and pneumonia","volume":"57","year":"2022","journal-title":"Invest Radiol"},{"key":"bib34-20250802","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.clinimag.2020.12.041","article-title":"Diagnostic accuracy of low-dose and ultra-low-dose CT in detection of chest pathology: a systematic review","volume":"74","year":"2021","journal-title":"Clin Imaging"},{"key":"bib35-20250802","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1097\/RLI.0000000000000895","article-title":"Potential of photon-counting detector CT for radiation dose reduction for the assessment of interstitial lung disease in patients with systemic sclerosis","volume":"57","year":"2022","journal-title":"Invest Radiol"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000968","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T19:07:22Z","timestamp":1754161642000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000968"}},"subtitle":["A New Era for Morphology and Function"],"short-title":[],"issued":{"date-parts":[[2023,3,11]]},"references-count":33,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000968","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2023,3,11]]}}}