{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T17:25:38Z","timestamp":1787505938143,"version":"build-2736575974"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Invest Radiol"],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    In the past decades, we have witnessed tremendous technical innovations in computed tomography (CT) imaging. These included improvements in temporal and spatial resolution, lowering of the radiation dose, the introduction of dual-energy and multi-energy imaging, automated image preprocessing and machine learning algorithms, and, most recently, the development and clinical introduction of photon-counting detector CT. This special issue of\n                    <jats:italic toggle=\"yes\">Investigative Radiology<\/jats:italic>\n                    comprises a collection of expert summaries and reviews on this most impactful recent innovation and cutting-edge technology of photon-counting detector CT. It includes articles on technical details about this new CT scanner type and summaries of the first clinical experience in cardiac and vascular imaging, neuroimaging, as well as chest and abdominal imaging, and concludes with an outlook to new contrast agents with potential for k-edge imaging, which are on the horizon.\n                  <\/jats:p>","DOI":"10.1097\/rli.0000000000000985","type":"journal-article","created":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T13:05:15Z","timestamp":1682946315000},"page":"439-440","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":18,"title":["The Future Arrived"],"prefix":"10.1097","volume":"58","author":[{"given":"Hatem","family":"Alkadhi","sequence":"first","affiliation":[{"name":"Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Val","family":"Runge","sequence":"additional","affiliation":[{"name":"Department of Diagnostic, Interventional, and Pediatric Radiology, University Hospital of Bern, Inselspital, University of Bern, Bern, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,4,30]]},"reference":[{"key":"bib1-20250802","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1097\/RLI.0000000000000172","article-title":"Evolution in computed tomography: the battle for speed and dose","volume":"50","year":"2015","journal-title":"Invest Radiol"},{"key":"bib2-20250802","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/RLI.0000000000000601","article-title":"Recent and upcoming technological developments in computed tomography: high speed, low dose, deep learning, multienergy","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib3-20250802","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1097\/RLI.0000000000000680","article-title":"Hounsfield's legacy","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib4-20250802","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1097\/RLI.0000000000000668","article-title":"The future of computed tomography: personalized, functional, and precise","volume":"55","year":"2020","journal-title":"Invest Radiol"},{"key":"bib5-20250802","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1097\/RLI.0000000000000897","article-title":"Ultra-high-resolution coronary CT angiography with photon-counting detector CT: feasibility and image characterization","volume":"57","year":"2022","journal-title":"Invest Radiol"},{"key":"bib6-20250802","doi-asserted-by":"crossref","first-page":"20220544","DOI":"10.1259\/bjr.20220544","article-title":"Photon-counting detector CT: early clinical experience review","year":"2023","journal-title":"Br J Radiol"},{"key":"bib7-20250802","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/RLI.0000000000000816","article-title":"High-pitch photon-counting detector computed tomography angiography of the aorta: intraindividual comparison to energy-integrating detector computed tomography at equal radiation dose","volume":"57","year":"2022","journal-title":"Invest Radiol"},{"key":"bib8-20250802","article-title":"Technical basics and clinical benefits of photon-counting CT","year":"2023","journal-title":"Invest Radiol"},{"key":"bib9-20250802","article-title":"Standardization and quantitative imaging with photon-counting detector CT","year":"2023","journal-title":"Invest Radiol"},{"key":"bib10-20250802","article-title":"First experience with a whole-body spectral photon-counting CT clinical prototype","year":"2023","journal-title":"Invest Radiol"},{"key":"bib11-20250802","article-title":"Advanced neuroimaging with photon-counting detector CT","year":"2023","journal-title":"Invest Radiol"},{"key":"bib12-20250802","article-title":"Ultra-high-resolution photon-counting CT imaging of the chest: a new era for morphology and function","year":"2023","journal-title":"Invest Radiol"},{"key":"bib13-20250802","article-title":"Exploiting the potential of photon-counting CT in abdominal imaging","year":"2023","journal-title":"Invest Radiol"},{"key":"bib14-20250802","article-title":"New horizons in vascular imaging with photon-counting detector CT","year":"2023","journal-title":"Invest Radiol"},{"key":"bib15-20250802","article-title":"Characterizing the heart and the myocardium with photon-counting CT","year":"2023","journal-title":"Invest Radiol"},{"key":"bib16-20250802","article-title":"New contrast media for K-edge imaging with photon-counting detector CT","year":"2023","journal-title":"Invest Radiol"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000985","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T19:05:38Z","timestamp":1754161538000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000000985"}},"subtitle":["Photon-Counting Detector CT"],"short-title":[],"issued":{"date-parts":[[2023,4,30]]},"references-count":16,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000000985","relation":{},"ISSN":["1536-0210","0020-9996"],"issn-type":[{"value":"1536-0210","type":"electronic"},{"value":"0020-9996","type":"print"}],"subject":[],"published":{"date-parts":[[2023,4,30]]}}}