{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T08:00:23Z","timestamp":1780300823919,"version":"3.54.0"},"reference-count":93,"publisher":"Ovid Technologies (Wolters Kluwer Health)","funder":[{"name":"JSPS Kakenhi","award":["23K07189"],"award-info":[{"award-number":["23K07189"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Quantitative synthetic MRI (SyMRI) enables simultaneous acquisition of quantitative T1, T2, and proton density maps and retrospective generation of multiple contrast-weighted images from a single acquisition. By moving beyond conventional qualitative MRI, SyMRI may improve workflow efficiency while providing objective tissue biomarkers. Although most extensively studied in neuroimaging, its application to body MRI has expanded rapidly. This narrative review summarizes the technical basis of body SyMRI, focusing on the predominant 2-dimensional QRAPMASTER\/multidynamic multiecho (MDME) framework and the newer 3-dimensional quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (QALAS) approach, and discusses current evidence across breast, prostate, gynecologic, rectal, head and neck, and musculoskeletal imaging. Available studies indicate that SyMRI is technically feasible across these applications and shows promise for lesion characterization, tumor grading, prognostic assessment, treatment-response evaluation, and quantitative analysis of normal and diseased tissues. In several settings, SyMRI-derived parameters provide additional value when combined with diffusion-weighted imaging, dynamic contrast-enhanced MRI, clinicopathologic variables, histogram analysis, radiomics, and predictive modeling. However, current evidence remains limited by small, single-center, and methodologically heterogeneous studies, and most body applications still rely on two-dimensional implementations. Future progress will depend on multicenter prospective validation, standardization of quantitative workflows, and broader evaluation of newer three-dimensional methods.<\/jats:p>","DOI":"10.1097\/rli.0000000000001297","type":"journal-article","created":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T07:00:10Z","timestamp":1780297210000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Quantitative Synthetic MRI in Body Imaging"],"prefix":"10.1097","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-4439-7719","authenticated-orcid":false,"given":"Javkhlan","family":"Maikhuu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5277-3249","authenticated-orcid":false,"given":"Akifumi","family":"Hagiwara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuhiro","family":"Sano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shohei","family":"Fujita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andica","family":"Christina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junko","family":"Kikuta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideo","family":"Kawasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koji","family":"Kamagata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,6,1]]},"reference":[{"key":"R1-20260601","first-page":"466","article-title":"Magnetic resonance image synthesis. Clinical implementation","volume":"369","author":"Riederer","year":"1986","journal-title":"Acta Radiol Suppl"},{"key":"R2-20260601","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1002\/mrm.21165","article-title":"Novel method for rapid, simultaneous T1, T2*, and proton density quantification","volume":"57","author":"Warntjes","year":"2007","journal-title":"Magn Reson Med"},{"key":"R3-20260601","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1002\/mrm.21635","article-title":"Rapid magnetic resonance quantification on the brain: optimization for clinical usage","volume":"60","author":"Warntjes","year":"2008","journal-title":"Magnetic Resonance in Medicine"},{"key":"R4-20260601","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1097\/RLI.0000000000000365","article-title":"SyMRI of the brain: rapid quantification of relaxation rates and proton density, with synthetic MRI, automatic brain segmentation, and myelin measurement","volume":"52","author":"Hagiwara","year":"2017","journal-title":"Invest Radiol"},{"key":"R5-20260601","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1097\/RLI.0000000000000666","article-title":"Variability and standardization of quantitative imaging: monoparametric to multiparametric quantification, radiomics, and artificial intelligence","volume":"55","author":"Hagiwara","year":"2020","journal-title":"Invest Radiol"},{"key":"R6-20260601","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1002\/jmri.27440","article-title":"Synthetic MRI: technologies and applications in neuroradiology","volume":"55","author":"Ji","year":"2022","journal-title":"J Magn Reson Imaging"},{"key":"R7-20260601","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1097\/RLI.0000000000000962","article-title":"Multiparametric MRI: from simultaneous rapid acquisition methods and analysis techniques using scoring, machine learning, radiomics, and deep learning to the generation of novel metrics","volume":"58","author":"Hagiwara","year":"2023","journal-title":"Invest Radiol"},{"key":"R8-20260601","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.3174\/ajnr.A5227","article-title":"Synthetic MRI for clinical neuroimaging: results of the magnetic resonance image compilation (MAGiC) prospective, multicenter, multireader trial","volume":"38","author":"Tanenbaum","year":"2017","journal-title":"AJNR Am J Neuroradiol"},{"key":"R9-20260601","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1148\/radiol.211519","article-title":"Primary multiparametric quantitative brain MRI: state-of-the-art relaxometric and proton density mapping techniques","volume":"305","author":"Jara","year":"2022","journal-title":"Radiology"},{"key":"R10-20260601","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1186\/s12968-014-0102-0","article-title":"Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS","volume":"16","author":"Kvernby","year":"2014","journal-title":"J Cardiovasc Magn Reson"},{"key":"R11-20260601","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.mri.2019.08.031","article-title":"Three-dimensional high-resolution simultaneous quantitative mapping of the whole brain with 3D-QALAS: an accuracy and repeatability study","volume":"63","author":"Fujita","year":"2019","journal-title":"Magn Reson Imaging"},{"key":"R12-20260601","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1053\/j.sult.2025.10.003","article-title":"Application of synthetic magnetic resonance imaging techniques based on MDME sequences in cognitive impairment disorders","volume":"47","author":"Qiao","year":"2026","journal-title":"Semin Ultrasound CT MR"},{"key":"R13-20260601","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1097\/RMR.0000000000000189","article-title":"Synthetic brain MRI: review of current concepts and future directions","volume":"27","author":"Gon\u00e7alves","year":"2018","journal-title":"Top Magn Reson Imaging"},{"key":"R14-20260601","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1515\/dx-2024-0168","article-title":"Technical aspects and clinical applications of synthetic MRI: a scoping review","volume":"12","author":"Pires","year":"2025","journal-title":"Diagnosis (Berl)"},{"key":"R15-20260601","doi-asserted-by":"crossref","first-page":"20180479","DOI":"10.1259\/bjr.20180479","article-title":"The feasibility of synthetic MRI in breast cancer patients: comparison of T(2) relaxation time with multiecho spin echo T(2) mapping method","volume":"92","author":"Jung","year":"2019","journal-title":"Br J Radiol"},{"key":"R16-20260601","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1002\/jmri.27075","article-title":"Diagnosis and grading of prostate cancer by relaxation maps from synthetic MRI","volume":"52","author":"Cui","year":"2020","journal-title":"J Magn Reson Imaging"},{"key":"R17-20260601","doi-asserted-by":"crossref","first-page":"3580","DOI":"10.21037\/qims-22-24","article-title":"Diagnostic performance of synthetic magnetic resonance imaging in the prognostic evaluation of rectal cancer","volume":"12","author":"Ma","year":"2022","journal-title":"Quant Imaging Med Surg"},{"key":"R18-20260601","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1148\/radiol.2018173007","article-title":"Synthetic MRI of the knee: phantom validation and comparison with conventional MRI","volume":"289","author":"Kumar","year":"2018","journal-title":"Radiology"},{"key":"R19-20260601","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/RLI.0000000000000510","article-title":"Linearity, bias, intrascanner repeatability, and interscanner reproducibility of quantitative multidynamic multiecho sequence for rapid simultaneous relaxometry at 3 T: a validation study with a standardized phantom and healthy controls","volume":"54","author":"Hagiwara","year":"2019","journal-title":"Invest Radiol"},{"key":"R20-20260601","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1002\/mrm.29939","article-title":"Cross-vendor multiparametric mapping of the human brain using 3D-QALAS: a multicenter and multivendor study","volume":"91","author":"Fujita","year":"2024","journal-title":"Magn Reson Med"},{"key":"R21-20260601","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1002\/jmri.28683","article-title":"Feasibility of quantitative mri using 3D-QALAS for discriminating immunohistochemical status in invasive ductal carcinoma of the breast","volume":"58","author":"Amano","year":"2023","journal-title":"J Magn Reson Imaging"},{"key":"R22-20260601","doi-asserted-by":"crossref","first-page":"1834","DOI":"10.1002\/jmri.26744","article-title":"3D quantitative synthetic MRI-derived cortical thickness and subcortical brain volumes: scan-rescan repeatability and comparison with conventional T(1) -weighted images","volume":"50","author":"Fujita","year":"2019","journal-title":"J Magn Reson Imaging"},{"key":"R23-20260601","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1097\/RLI.0000000000000744","article-title":"Accelerated isotropic multiparametric imaging by high spatial resolution 3D-QALAS with compressed sensing: a phantom, volunteer, and patient study","volume":"56","author":"Fujita","year":"2021","journal-title":"Invest Radiol"},{"key":"R24-20260601","doi-asserted-by":"crossref","first-page":"2019","DOI":"10.1002\/mrm.29786","article-title":"SSL-QALAS: Self-Supervised Learning for rapid multiparameter estimation in quantitative MRI using 3D-QALAS","volume":"90","author":"Jun","year":"2023","journal-title":"Magn Reson Med"},{"key":"R25-20260601","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1186\/s13244-021-01063-w","article-title":"A preliminary study of synthetic magnetic resonance imaging in rectal cancer: imaging quality and preoperative assessment","volume":"12","author":"Zhao","year":"2021","journal-title":"Insights Imaging"},{"key":"R26-20260601","doi-asserted-by":"crossref","first-page":"431","DOI":"10.2463\/mrms.mp.2020-0132","article-title":"Investigating the image quality and utility of synthetic MRI in the breast","volume":"20","author":"Fujioka","year":"2021","journal-title":"Magn Reson Med Sci"},{"key":"R27-20260601","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1002\/jmri.27435","article-title":"Investigation of synthetic relaxometry and diffusion measures in the differentiation of benign and malignant breast lesions as compared to BI-RADS","volume":"53","author":"Gao","year":"2021","journal-title":"J Magn Reson Imaging"},{"key":"R28-20260601","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1007\/s00330-022-09027-4","article-title":"Synthetic MRI in differentiating benign from metastatic retropharyngeal lymph node: combination with diffusion-weighted imaging","volume":"33","author":"Wang","year":"2023","journal-title":"Eur Radiol"},{"key":"R29-20260601","doi-asserted-by":"crossref","first-page":"5344","DOI":"10.1007\/s00330-023-09553-9","article-title":"Histogram analysis of quantitative parameters from synthetic MRI: correlations with prognostic factors in nasopharyngeal carcinoma","volume":"33","author":"Yang","year":"2023","journal-title":"Eur Radiol"},{"key":"R30-20260601","doi-asserted-by":"crossref","first-page":"2058460118769686","DOI":"10.1177\/2058460118769686","article-title":"Feasibility of synthetic MRI in knee imaging in routine practice","volume":"7","author":"Boudabbous","year":"2018","journal-title":"Acta Radiol Open"},{"key":"R31-20260601","doi-asserted-by":"crossref","first-page":"112069","DOI":"10.1016\/j.ejrad.2025.112069","article-title":"Optimization of shoulder synthetic MRI through post-processing and comparison with conventional MRI","volume":"186","author":"Nishizawa","year":"2025","journal-title":"Eur J Radiol"},{"key":"R32-20260601","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.3174\/ajnr.A5728","article-title":"Feasibility of a synthetic MR imaging sequence for spine imaging","volume":"39","author":"Vargas","year":"2018","journal-title":"AJNR Am J Neuroradiol"},{"key":"R33-20260601","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1186\/s40644-020-00365-4","article-title":"The diagnostic performance of quantitative mapping in breast cancer patients: a preliminary study using synthetic MRI","volume":"20","author":"Meng","year":"2020","journal-title":"Cancer Imaging"},{"key":"R34-20260601","doi-asserted-by":"crossref","first-page":"398.e1","DOI":"10.1016\/j.crad.2019.12.021","article-title":"Utility of synthetic MRI in predicting the Ki-67 status of oestrogen receptor-positive breast cancer: a feasibility study","volume":"75","author":"Matsuda","year":"2020","journal-title":"Clin Radiol"},{"key":"R35-20260601","doi-asserted-by":"crossref","first-page":"17978","DOI":"10.1038\/s41598-023-45079-2","article-title":"Synthetic MRI in breast cancer: differentiating benign from malignant lesions and predicting immunohistochemical expression status","volume":"13","author":"Li","year":"2023","journal-title":"Sci Rep"},{"key":"R36-20260601","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1002\/jmri.27362","article-title":"Enhanced masses on contrast-enhanced breast: differentiation using a combination of dynamic contrast-enhanced MRI and quantitative evaluation with synthetic MRI","volume":"53","author":"Matsuda","year":"2021","journal-title":"J Magn Reson Imaging"},{"key":"R37-20260601","doi-asserted-by":"crossref","first-page":"111920","DOI":"10.1016\/j.ejrad.2025.111920","article-title":"A nomogram based on multiparametric magnetic resonance imaging improves the diagnostic performance of breast lesions diagnosed as BI-RADS category 4: a comparative study with the Kaiser score","volume":"183","author":"Yang","year":"2025","journal-title":"Eur J Radiol"},{"key":"R38-20260601","doi-asserted-by":"crossref","first-page":"110168","DOI":"10.1016\/j.ejrad.2022.110168","article-title":"Synthetic MRI with quantitative mappings for identifying receptor status, proliferation rate, and molecular subtypes of breast cancer","volume":"148","author":"Gao","year":"2022","journal-title":"Eur J Radiol"},{"key":"R39-20260601","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/j.crad.2022.06.019","article-title":"Utility of synthetic MRI in predicting pathological complete response of various breast cancer subtypes prior to neoadjuvant chemotherapy","volume":"77","author":"Matsuda","year":"2022","journal-title":"Clin Radiol"},{"key":"R40-20260601","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1038\/s41598-025-31322-5","article-title":"A novel biomarker for identifying HER2-low breast cancer using synthetic MRI","volume":"16","author":"Liu","year":"2025","journal-title":"Sci Rep"},{"key":"R41-20260601","doi-asserted-by":"crossref","first-page":"109697","DOI":"10.1016\/j.ejrad.2021.109697","article-title":"Histogram analysis of quantitative parameters from synthetic MRI: correlations with prognostic factors and molecular subtypes in invasive ductal breast cancer","volume":"139","author":"Li","year":"2021","journal-title":"Eur J Radiol"},{"key":"R42-20260601","doi-asserted-by":"crossref","first-page":"109838","DOI":"10.1016\/j.ejrad.2021.109838","article-title":"Triple-negative breast cancer on contrast-enhanced MRI and synthetic MRI: a comparison with non-triple-negative breast carcinoma","volume":"142","author":"Matsuda","year":"2021","journal-title":"Eur J Radiol"},{"key":"R43-20260601","first-page":"457","article-title":"Differential diagnosis of benign and malignant breast lesions using quantitative synthetic magnetic resonance imaging","volume":"42","author":"Zhang","year":"2022","journal-title":"Nan Fang Yi Ke Da Xue Xue Bao"},{"key":"R44-20260601","doi-asserted-by":"crossref","first-page":"e230009","DOI":"10.1148\/rycan.230009","article-title":"A radiomics model based on synthetic MRI acquisition for predicting neoadjuvant systemic treatment response in triple-negative breast cancer","volume":"5","author":"Hwang","year":"2023","journal-title":"Radiol Imaging Cancer"},{"key":"R45-20260601","doi-asserted-by":"crossref","first-page":"6746326","DOI":"10.1155\/2023\/6746326","article-title":"Predicting of Ki-67 expression level using diffusion-weighted and synthetic magnetic resonance imaging in invasive ductal breast cancer","volume":"2023","author":"Zhang","year":"2023","journal-title":"Breast J"},{"key":"R46-20260601","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1186\/s13244-023-01492-9","article-title":"Correlation between synthetic MRI relaxometry and apparent diffusion coefficient in breast cancer subtypes with different neoadjuvant therapy response","volume":"14","author":"Jiang","year":"2023","journal-title":"Insights Imaging"},{"key":"R47-20260601","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1002\/jmri.28597","article-title":"Time course changes of synthetic relaxation time during neoadjuvant chemotherapy in breast cancer: the optimal parameter for treatment response evaluation","volume":"58","author":"Zhao","year":"2023","journal-title":"J Magn Reson Imaging"},{"key":"R48-20260601","doi-asserted-by":"crossref","first-page":"4369","DOI":"10.1016\/j.acra.2025.04.020","article-title":"Neoadjuvant chemotherapy efficacy in breast cancer: insights from magnetic resonance imaging compilation (MAGIC)","volume":"32","author":"Wu","year":"2025","journal-title":"Acad Radiol"},{"key":"R49-20260601","doi-asserted-by":"crossref","first-page":"111452","DOI":"10.1016\/j.ejrad.2024.111452","article-title":"Investigation of synthetic MRI with quantitative parameters for discriminating axillary lymph nodes status in invasive breast cancer","volume":"175","author":"Qu","year":"2024","journal-title":"Eur J Radiol"},{"key":"R50-20260601","doi-asserted-by":"crossref","first-page":"111325","DOI":"10.1016\/j.ejrad.2024.111325","article-title":"Whole-tumor histogram models based on quantitative maps from synthetic MRI for predicting axillary lymph node status in invasive ductal breast cancer","volume":"172","author":"Zeng","year":"2024","journal-title":"Eur J Radiol"},{"key":"R51-20260601","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1186\/s12880-025-01930-8","article-title":"Diagnostic accuracy of a machine learning model using radiomics features from breast synthetic MRI","volume":"25","author":"Matsuda","year":"2025","journal-title":"BMC Med Imaging"},{"key":"R52-20260601","doi-asserted-by":"crossref","first-page":"112414","DOI":"10.1016\/j.ejrad.2025.112414","article-title":"Synthetic MRI as a T2WI alternative in bp-MRI: comparable image quality and improved PI-RADS performance","volume":"193","author":"Yun","year":"2025","journal-title":"Eur J Radiol"},{"key":"R53-20260601","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1007\/s00261-024-04227-6","article-title":"Histogram analysis of MR quantitative parameters: are they correlated with prognostic factors in prostate cancer?","volume":"49","author":"Chen","year":"2024","journal-title":"Abdominal Radiology"},{"key":"R54-20260601","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1177\/02841851251315717","article-title":"Assessing the aggressiveness of prostate cancer using ADC and relaxation maps from synthetic MRI","volume":"66","author":"Sirolu","year":"2025","journal-title":"Acta Radiol"},{"key":"R55-20260601","doi-asserted-by":"crossref","first-page":"100403","DOI":"10.1016\/j.ejro.2022.100403","article-title":"Synthetic magnetic resonance imaging for primary prostate cancer evaluation: diagnostic potential of a non-contrast-enhanced bi-parametric approach enhanced with relaxometry measurements","volume":"9","author":"Arita","year":"2022","journal-title":"Eur J Radiol Open"},{"key":"R56-20260601","doi-asserted-by":"crossref","first-page":"1510049","DOI":"10.3389\/fonc.2025.1510049","article-title":"Prospective evaluation of mpMRI-derived nomograms for detecting prostate cancer in PI-RADS v2.1 upgraded and non-upgraded lesions","volume":"15","author":"Yi","year":"2025","journal-title":"Frontiers in Oncology"},{"key":"R57-20260601","doi-asserted-by":"crossref","first-page":"841761","DOI":"10.3389\/fonc.2022.841761","article-title":"Synthetic MRI for radiotherapy planning for brain and prostate cancers: phantom validation and patient evaluation","volume":"12","author":"Gouel","year":"2022","journal-title":"Front Oncol"},{"key":"R58-20260601","doi-asserted-by":"crossref","first-page":"1304793","DOI":"10.3389\/fonc.2024.1304793","article-title":"Predicting the status of lymphovascular space invasion using quantitative parameters from synthetic MRI in cervical squamous cell carcinoma without lymphatic metastasis","volume":"14","author":"Guo","year":"2024","journal-title":"Front Oncol"},{"key":"R59-20260601","doi-asserted-by":"crossref","first-page":"e1459","DOI":"10.1016\/j.crad.2024.08.021","article-title":"Feasibility of using synthetic MRI to predict lymphatic vascular space invasion status in early-stage cervical cancer: added value to morphological MRI","volume":"79","author":"Huang","year":"2024","journal-title":"Clinical radiology"},{"key":"R60-20260601","doi-asserted-by":"crossref","first-page":"2956","DOI":"10.3390\/diagnostics12122956","article-title":"Tissue characteristics of endometrial carcinoma analyzed by quantitative synthetic MRI and diffusion-weighted imaging","volume":"12","author":"Wang","year":"2022","journal-title":"Diagnostics (Basel)"},{"key":"R61-20260601","doi-asserted-by":"crossref","first-page":"20220596","DOI":"10.1259\/bjr.20220596","article-title":"Application of synthetic magnetic resonance imaging and DWI for evaluation of prognostic factors in cervical carcinoma: a prospective preliminary study","volume":"96","author":"Zhang","year":"2023","journal-title":"Br J Radiol"},{"key":"R62-20260601","first-page":"346","article-title":"Preoperative risk assessment of endometrial cancer using histogram analysis of weighted and quantitative MRI images","volume":"51(1)","author":"Palm\u00e9r","year":"2026","journal-title":"Abdom Radiol (NY)"},{"key":"R63-20260601","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1007\/s00330-022-09191-7","article-title":"Quantitative synthetic MRI for predicting locally advanced rectal cancer response to neoadjuvant chemoradiotherapy","volume":"33","author":"Lian","year":"2023","journal-title":"Eur Radiol"},{"key":"R64-20260601","doi-asserted-by":"crossref","first-page":"1805","DOI":"10.21037\/qims-20-659","article-title":"Preoperative volumetric synthetic magnetic resonance imaging of the primary tumor for a more accurate prediction of lymph node metastasis in rectal cancer","volume":"11","author":"Zhao","year":"2021","journal-title":"Quant Imaging Med Surg"},{"key":"R65-20260601","doi-asserted-by":"crossref","first-page":"109658","DOI":"10.1016\/j.ejrad.2021.109658","article-title":"Prediction of pathological prognostic factors of rectal cancer by relaxation maps from synthetic magnetic resonance imaging","volume":"138","author":"Zhao","year":"2021","journal-title":"Eur J Radiol"},{"key":"R66-20260601","doi-asserted-by":"crossref","first-page":"238.e9","DOI":"10.1016\/j.crad.2020.10.010","article-title":"Investigation of the feasibility of synthetic MRI in the differential diagnosis of non-keratinising nasopharyngeal carcinoma and benign hyperplasia using different contoured methods for delineation of the region of interest","volume":"76","author":"Meng","year":"2021","journal-title":"Clin Radiol"},{"key":"R67-20260601","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1007\/s11604-024-01578-4","article-title":"Multiparametric approach with synthetic MR imaging for diagnosing salivary gland lesions","volume":"42","author":"Takumi","year":"2024","journal-title":"Jpn J Radiol"},{"key":"R68-20260601","doi-asserted-by":"crossref","first-page":"20230103","DOI":"10.1259\/dmfr.20230103","article-title":"Synthetic MRI for the quantitative and morphologic assessment of head and neck tumors: a preliminary study","volume":"52","author":"Zhang","year":"2023","journal-title":"Dentomaxillofac Radiol"},{"key":"R69-20260601","doi-asserted-by":"crossref","first-page":"110715","DOI":"10.1016\/j.ejrad.2023.110715","article-title":"Histogram analysis of synthetic magnetic resonance imaging: correlations with histopathological factors in head and neck squamous cell carcinoma","volume":"160","author":"Yang","year":"2023","journal-title":"Eur J Radiol"},{"key":"R70-20260601","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/s13244-023-01411-y","article-title":"Pretreatment synthetic magnetic resonance imaging predicts disease progression in nonmetastatic nasopharyngeal carcinoma after intensity modulation radiation therapy","volume":"14","author":"Yang","year":"2023","journal-title":"Insights Imaging"},{"key":"R71-20260601","doi-asserted-by":"crossref","first-page":"7752","DOI":"10.1007\/s00330-025-11691-1","article-title":"Rapid multiparametric quantitative MRI for predicting the activity of thyroid-associated ophthalmopathy: combination with clinical characteristics","volume":"35","author":"Wang","year":"2025","journal-title":"Eur Radiol"},{"key":"R72-20260601","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.1093\/bjr\/tqae095","article-title":"Synthetic MRI and diffusion-weighted imaging for differentiating nasopharyngeal lymphoma from nasopharyngeal carcinoma: combination with morphological features","volume":"97","author":"Zhang","year":"2024","journal-title":"Br J Radiol"},{"key":"R73-20260601","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s12880-023-00968-w","article-title":"The utility of texture analysis based on quantitative synthetic magnetic resonance imaging in nasopharyngeal carcinoma: a preliminary study","volume":"23","author":"Yang","year":"2023","journal-title":"BMC Med Imaging"},{"key":"R74-20260601","doi-asserted-by":"crossref","first-page":"6820","DOI":"10.1007\/s00330-024-10696-6","article-title":"Synthetic MRI and amide proton transfer-weighted MRI for differentiating between benign and malignant sinonasal lesions","volume":"34","author":"Xiang","year":"2024","journal-title":"Eur Radiol"},{"key":"R75-20260601","doi-asserted-by":"crossref","first-page":"112048","DOI":"10.1016\/j.ejrad.2025.112048","article-title":"The value of Synthetic MRI in discriminating metastatic and non-metastatic lymph nodes in head and neck squamous cell carcinoma, compared with DWI and subjective experience","volume":"186","author":"Wei","year":"2025","journal-title":"Eur J Radiol"},{"key":"R76-20260601","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1177\/02841851241257775","article-title":"The value of synthetic MRI for quantitative analysis in the diagnosis of cervical lymph node metastasis in thyroid cancer","volume":"65","author":"Wei","year":"2024","journal-title":"Acta Radiol"},{"key":"R77-20260601","doi-asserted-by":"crossref","first-page":"135","DOI":"10.3348\/kjr.2024.0385","article-title":"Synthetic MRI combined with clinicopathological characteristics for pretreatment prediction of chemoradiotherapy response in advanced nasopharyngeal carcinoma","volume":"26","author":"Chen","year":"2025","journal-title":"Korean J Radiol"},{"key":"R78-20260601","doi-asserted-by":"crossref","first-page":"1803","DOI":"10.1007\/s11604-025-01824-3","article-title":"Whole-tumor histogram analysis of synthetic MRI relaxation maps for nasopharyngeal carcinoma: correlations with histopathologic components","volume":"43","author":"Zhou","year":"2025","journal-title":"Japanese Journal of Radiology"},{"key":"R79-20260601","doi-asserted-by":"crossref","first-page":"344","DOI":"10.2463\/mrms.tn.2017-0121","article-title":"Quantitative T(2) mapping of knee cartilage: comparison between the synthetic MR imaging and the CPMG sequence","volume":"17","author":"Lee","year":"2018","journal-title":"Magn Reson Med Sci"},{"key":"R80-20260601","doi-asserted-by":"crossref","first-page":"20170350","DOI":"10.1259\/bjr.20170350","article-title":"Initial experience with synthetic MRI of the knee at 3T: comparison with conventional T(1) weighted imaging and T(2) mapping","volume":"90","author":"Park","year":"2017","journal-title":"Br J Radiol"},{"key":"R81-20260601","doi-asserted-by":"crossref","first-page":"311","DOI":"10.3348\/kjr.2018.19.2.311","article-title":"Clinical feasibility of synthetic magnetic resonance imaging in the diagnosis of internal derangements of the knee","volume":"19","author":"Yi","year":"2018","journal-title":"Korean J Radiol"},{"key":"R82-20260601","doi-asserted-by":"crossref","first-page":"2573","DOI":"10.1007\/s00330-018-5800-9","article-title":"Double-inversion recovery with synthetic magnetic resonance: a pilot study for assessing synovitis of the knee joint compared to contrast-enhanced magnetic resonance imaging","volume":"29","author":"Yi","year":"2019","journal-title":"Eur Radiol"},{"key":"R83-20260601","doi-asserted-by":"crossref","first-page":"100526","DOI":"10.1016\/j.ejro.2023.100526","article-title":"Difference in quantitative MRI measurements of cartilage between Wiberg type III patella and stable patella based on a 3.0-T synthetic MRI sequence","volume":"11","author":"Li","year":"2023","journal-title":"Eur J Radiol Open"},{"key":"R84-20260601","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1186\/s12891-024-07375-4","article-title":"Quantitative evaluation of meniscus injury using synthetic magnetic resonance imaging","volume":"25","author":"Zhang","year":"2024","journal-title":"BMC Musculoskelet Disord"},{"key":"R85-20260601","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1186\/s40001-025-02763-5","article-title":"Quantitative evaluation of postoperative status after meniscal repair using synthetic magnetic resonance imaging","volume":"30","author":"Zhang","year":"2025","journal-title":"Eur J Med Res"},{"key":"R86-20260601","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/s13244-025-01911-z","article-title":"Super-resolution synthetic MRI using deep learning reconstruction for accurate diagnosis of knee osteoarthritis","volume":"16","author":"Wang","year":"2025","journal-title":"Insights Imaging"},{"key":"R87-20260601","doi-asserted-by":"crossref","first-page":"e19123","DOI":"10.7717\/peerj.19123","article-title":"Quantitative MRI reveals infrapatellar fat pad changes after running a marathon","volume":"13","author":"Zhao","year":"2025","journal-title":"PeerJ"},{"key":"R88-20260601","doi-asserted-by":"crossref","first-page":"112279","DOI":"10.1016\/j.ejrad.2025.112279","article-title":"Preliminary synthetic MRI study on Achilles tendon dynamics in amateur marathoners","volume":"191","author":"Hou","year":"2025","journal-title":"Eur J Radiol"},{"key":"R89-20260601","doi-asserted-by":"crossref","first-page":"e37307","DOI":"10.1016\/j.heliyon.2024.e37307","article-title":"Quantitative assessment of rotator cuff injuries using synthetic MRI and IDEAL-IQ imaging techniques","volume":"10","author":"Tian","year":"2024","journal-title":"Heliyon"},{"key":"R90-20260601","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1177\/0284185119871670","article-title":"Synthetic MRI of the lumbar spine at 3.0 T: feasibility and image quality comparison with conventional MRI","volume":"61","author":"Zhang","year":"2020","journal-title":"Acta Radiol"},{"key":"R91-20260601","doi-asserted-by":"crossref","first-page":"788","DOI":"10.3174\/ajnr.A5566","article-title":"Normal values of magnetic relaxation parameters of spine components with the synthetic MRI Sequence","volume":"39","author":"Drake-P\u00e9rez","year":"2018","journal-title":"AJNR Am J Neuroradiol"},{"key":"R92-20260601","doi-asserted-by":"crossref","first-page":"414","DOI":"10.3171\/2021.6.SPINE21666","article-title":"Simple parameters of synthetic MRI for assessment of bone density in patients with spinal degenerative disease","volume":"36","author":"Chang","year":"2022","journal-title":"J Neurosurg Spine"},{"key":"R93-20260601","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1186\/s12880-023-01010-9","article-title":"Application of magnetic resonance image compilation (MAGiC) in the diagnosis of middle-aged and elderly women with osteoporosis","volume":"23","author":"Chen","year":"2023","journal-title":"BMC Med Imaging"}],"container-title":["Investigative Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000001297","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T07:00:23Z","timestamp":1780297223000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLI.0000000000001297"}},"subtitle":["Technical Basis, Current Applications, and Future Directions"],"short-title":[],"issued":{"date-parts":[[2026,6,1]]},"references-count":93,"URL":"https:\/\/doi.org\/10.1097\/rli.0000000000001297","relation":{},"ISSN":["1536-0210"],"issn-type":[{"value":"1536-0210","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,1]]},"assertion":[{"value":"2026-04-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-11","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}