{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T21:55:55Z","timestamp":1790114155209,"version":"4.0.1"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Nucl Med"],"published-print":{"date-parts":[[2018,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Block sequential regularized expectation maximization (BSREM) is a Bayesian penalized-likelihood reconstruction algorithm for PET, which reaches full convergence without the detriment of deteriorating the image quality by noise. Therefore, BSREM might have implications particularly for the detection of small lesions, which may be beneficial in melanoma patients. Our case of a 70-year-old man with metastasized malignant melanoma illustrates the impact of such a novel iterative PET reconstruction algorithm. Whereas the lymph node metastases are seen with the latest generation ordered subset expectation maximization reconstruction, the in-transit metastases are identified straightforward only with BSREM reconstruction.<\/jats:p>","DOI":"10.1097\/rlu.0000000000002024","type":"journal-article","created":{"date-parts":[[2018,2,27]],"date-time":"2018-02-27T19:21:27Z","timestamp":1519759287000},"page":"370-371","source":"Crossref","is-referenced-by-count":19,"title":["BSREM Reconstruction for Improved Detection of In-Transit Metastases With Digital FDG-PET\/CT in Patients With Malignant Melanoma"],"prefix":"10.1097","volume":"43","author":[{"given":"Arwa","family":"Aljared","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdullah Awad","family":"Alharbi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin W.","family":"Huellner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20231021","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1245\/s10434-014-4100-0","article-title":"In-transit melanoma metastases: incidence, prognosis, and the role of lymphadenectomy","volume":"22","year":"2015","journal-title":"Ann Surg Oncol"},{"key":"bib2-20231021","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/RLU.0000000000000996","article-title":"18F-FDG-PET\/CT in the staging and management of melanoma: a prospective multicenter Ontario PET registry study","volume":"41","year":"2016","journal-title":"Clin Nucl Med"},{"key":"bib3-20231021","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/RLU.0000000000001456","article-title":"FDG-PET\/CT for monitoring response of melanoma to the novel oncolytic viral therapy talimogene laherparepvec","volume":"42","year":"2017","journal-title":"Clin Nucl Med"},{"key":"bib4-20231021","first-page":"e403","article-title":"18F-FDG-PET\/CT in the staging and management of melanoma: a prospective multicenter Ontario PET registry study","volume":"41","year":"2016","journal-title":"Clin Nucl Med"},{"key":"bib5-20231021","doi-asserted-by":"crossref","first-page":"e51","DOI":"10.1097\/RLU.0000000000001417","article-title":"Bilateral huge incidentalomas of isolated adrenal metastases from unknown primary melanoma revealed by 18F-FDG PET\/CT","volume":"42","year":"2017","journal-title":"Clin Nucl Med"},{"key":"bib6-20231021","doi-asserted-by":"crossref","first-page":"e0178936","DOI":"10.1371\/journal.pone.0178936","article-title":"18F-FDG silicon photomultiplier PET\/CT: a pilot study comparing semi-quantitative measurements with standard PET\/CT","volume":"12","year":"2017","journal-title":"PLoS One"},{"key":"bib7-20231021","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/MNM.0000000000000604","article-title":"Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET\/CT studies","volume":"38","year":"2017","journal-title":"Nucl Med Commun"},{"key":"bib8-20231021","article-title":"Does PET reconstruction method affect Deauville scoring in lymphoma patients?","year":"2017","journal-title":"J Nucl Med"},{"key":"bib9-20231021","doi-asserted-by":"crossref","first-page":"153","DOI":"10.2214\/AJR.17.18060","article-title":"Effect of a Bayesian penalized likelihood PET reconstruction compared with ordered subset expectation maximization on clinical image quality over a wide range of patient weights","volume":"210","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"bib10-20231021","doi-asserted-by":"crossref","first-page":"1873","DOI":"10.1016\/j.ejrad.2015.06.025","article-title":"Does a novel penalized likelihood reconstruction of 18F-FDG PET-CT improve signal-to-background in colorectal liver metastases?","volume":"84","year":"2015","journal-title":"Eur J Radiol"},{"key":"bib11-20231021","doi-asserted-by":"crossref","first-page":"e352","DOI":"10.1097\/RLU.0000000000001713","article-title":"The impact of a Bayesian penalized likelihood reconstruction algorithm on the evaluation of indeterminate pulmonary nodules by dual-time point 18F-FDG PET\/CT","volume":"42","year":"2017","journal-title":"Clin Nucl Med"},{"key":"bib12-20231021","doi-asserted-by":"crossref","first-page":"1716","DOI":"10.2967\/jnumed.112.103861","article-title":"Improvement in PET\/CT image quality with a combination of point-spread function and time-of-flight in relation to reconstruction parameters","volume":"53","year":"2012","journal-title":"J Nucl Med"},{"key":"bib13-20231021","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1007\/s00259-017-3727-z","article-title":"Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET","volume":"44","year":"2017","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"bib14-20231021","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1109\/TMI.2003.816960","article-title":"A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolution","volume":"22","year":"2003","journal-title":"IEEE Trans Med Imaging"},{"key":"bib15-20231021","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.2967\/jnumed.115.159301","article-title":"Phantom and clinical evaluation of the Bayesian penalized likelihood reconstruction algorithm Q.Clear on an LYSO PET\/CT system","volume":"56","year":"2015","journal-title":"J Nucl Med"},{"key":"bib16-20231021","doi-asserted-by":"crossref","first-page":"5733","DOI":"10.1088\/0031-9155\/60\/15\/5733","article-title":"Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET","volume":"60","year":"2015","journal-title":"Phys Med Biol"},{"key":"bib17-20231021","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.2967\/jnumed.116.185561","article-title":"Performance characteristics of the whole-body discovery IQ PET\/CT system","volume":"58","year":"2017","journal-title":"J Nucl Med"},{"key":"bib18-20231021","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1097\/MNM.0000000000000729","article-title":"A clinical evaluation of the impact of the Bayesian penalized likelihood reconstruction algorithm on PET FDG metrics","volume":"38","year":"2017","journal-title":"Nucl Med Commun"}],"container-title":["Clinical Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003072-201805000-00021","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,21]],"date-time":"2023-10-21T04:52:11Z","timestamp":1697863931000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003072-201805000-00021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/rlu.0000000000002024","relation":{},"ISSN":["1536-0229","0363-9762"],"issn-type":[{"value":"1536-0229","type":"electronic"},{"value":"0363-9762","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]}}}