{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T08:05:59Z","timestamp":1785225959017,"version":"3.55.0"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Nucl Med"],"published-print":{"date-parts":[[2019,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Parathyroid carcinoma is uncommon, and its coexistence with parathyroid adenoma is extremely rare. A 28-year-old woman with hyperparathyroidism underwent dual-phase <jats:sup>99m<\/jats:sup>Tc-sestamibi SPECT\/CT scan for presurgical evaluation. The images showed intense activity inside the left side thyroid and mild activity inside the right side of the thyroid. The histopathologic findings showed intrathyroidal parathyroid carcinoma on the left side and intrathyroid parathyroid adenoma on the right side.<\/jats:p>","DOI":"10.1097\/rlu.0000000000002755","type":"journal-article","created":{"date-parts":[[2019,8,23]],"date-time":"2019-08-23T02:48:05Z","timestamp":1566528485000},"page":"844-847","source":"Crossref","is-referenced-by-count":6,"title":["Hyperparathyroidism Due to Concurrent Parathyroid Carcinoma and Parathyroid Adenoma"],"prefix":"10.1097","volume":"44","author":[{"given":"Jiqin","family":"Yang","sequence":"first","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanmei","family":"Li","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Li","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pengfei","family":"Yang","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingyan","family":"Huang","sequence":"additional","affiliation":[{"name":"Pathology, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, People's Republic of China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,8,22]]},"reference":[{"key":"bib1-20230925","doi-asserted-by":"crossref","first-page":"2398","DOI":"10.1002\/hed.25781","article-title":"American Head and Neck Society Endocrine Surgery Section update on parathyroid imaging for surgical candidates with primary hyperparathyroidism","volume":"41","year":"2019","journal-title":"Head Neck"},{"key":"bib2-20230925","doi-asserted-by":"crossref","first-page":"3827","DOI":"10.1245\/s10434-012-2581-2","article-title":"Sestamibi imaging for primary hyperparathyroidism: the impact of surgeon interpretation and radiologist volume","volume":"19","year":"2012","journal-title":"Ann Surg Oncol"},{"key":"bib3-20230925","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/RLU.0000000000001941","article-title":"Prognostic value of 99mTc-sestamibi parathyroid scintigraphy in predicting future surgical eligibility in patients with asymptomatic primary hyperparathyroidism","volume":"43","year":"2018","journal-title":"Clin Nucl Med"},{"key":"bib4-20230925","doi-asserted-by":"crossref","first-page":"e109","DOI":"10.1097\/RLU.0000000000001447","article-title":"SPECT\/CT's advantage for preoperative localization of small parathyroid adenomas in primary hyperparathyroidism","volume":"42","year":"2017","journal-title":"Clin Nucl Med"},{"key":"bib5-20230925","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1007\/s13139-016-0438-5","article-title":"Usefulness of SPECT\/CT in parathyroid lesion detection in patients with thyroid parenchymal (99m)Tc-sestamibi retention","volume":"51","year":"2017","journal-title":"Nucl Med Mol Imaging"},{"key":"bib6-20230925","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1097\/RLU.0000000000001115","article-title":"Influence of multigland parathyroid disease on 99mTc-sestamibi SPECT\/CT","volume":"41","year":"2016","journal-title":"Clin Nucl Med"},{"key":"bib7-20230925","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/RLU.0000000000001958","article-title":"Ectopic undescended parathyroid adenoma\u2014SPECT\/CT avoids false-negative interpretation on 99mTc-MIBI dual-phase scintigraphy","volume":"43","year":"2018","journal-title":"Clin Nucl Med"},{"key":"bib8-20230925","first-page":"247","article-title":"Intrathyroid parathyroid adenoma potentially mimicking a parathyroid carcinoma","volume":"31","year":"2006","journal-title":"Minerva Endocrinol"},{"key":"bib9-20230925","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1002\/jcu.22090","article-title":"Intrathyroidal parathyroid carcinoma mimicking a thyroid nodule in a MEN type 1 patient","volume":"42","year":"2014","journal-title":"J Clin Ultrasound"},{"key":"bib10-20230925","doi-asserted-by":"crossref","first-page":"e362","DOI":"10.1097\/RLU.0000000000000357","article-title":"Recurrent parathyroid carcinoma appearing as FDG negative but MIBI positive","volume":"39","year":"2014","journal-title":"Clin Nucl Med"},{"key":"bib11-20230925","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1053\/j.semnuclmed.2014.08.001","article-title":"Bone SPECT\/CT in skeletal trauma","volume":"45","year":"2015","journal-title":"Semin Nucl Med"},{"key":"bib12-20230925","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1097\/RLU.0000000000000663","article-title":"Importance of SPECT\/CT in detecting multiple hemangiomas on 99mTc-labeled RBC blood pool scintigraphy","volume":"40","year":"2015","journal-title":"Clin Nucl Med"},{"key":"bib13-20230925","first-page":"25","article-title":"The added value of hybrid ventilation\/perfusion SPECT\/CT in patients with stable COPD or apparently healthy smokers. Cancer-suspected CT findings in the lungs are common when hybrid imaging is used","volume":"10","year":"2015","journal-title":"Int J Chron Obstruct Pulmon Dis"},{"key":"bib14-20230925","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.amjoto.2013.08.004","article-title":"Utility of SPECT\/CT for periparotid sentinel lymph node mapping in the surgical management of head and neck melanoma","volume":"35","year":"2014","journal-title":"Am J Otolaryngol"},{"key":"bib15-20230925","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1097\/RLU.0000000000001984","article-title":"SPECT\/CT MIBG imaging is crucial in the follow-up of the patients with high-risk neuroblastoma","volume":"43","year":"2018","journal-title":"Clin Nucl Med"},{"key":"bib16-20230925","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1097\/MNM.0b013e328337142c","article-title":"99mTc-WBC scintigraphy with SPECT\/CT in the evaluation of arterial graft infection","volume":"31","year":"2010","journal-title":"Nucl Med Commun"},{"key":"bib17-20230925","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/MNM.0b013e32832ed3a6","article-title":"Breast sentinel node imaging with low-dose SPECT\/CT","volume":"31","year":"2010","journal-title":"Nucl Med Commun"},{"key":"bib18-20230925","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.radonc.2018.07.023","article-title":"SPECT\/CT-guided elective nodal irradiation for head and neck cancer: estimation of clinical benefits using NTCP models","volume":"130","year":"2019","journal-title":"Radiother Oncol"}],"container-title":["Clinical Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLU.0000000000002755","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,25]],"date-time":"2023-09-25T06:01:55Z","timestamp":1695621715000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLU.0000000000002755"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,22]]},"references-count":18,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/rlu.0000000000002755","relation":{},"ISSN":["1536-0229","0363-9762"],"issn-type":[{"value":"1536-0229","type":"electronic"},{"value":"0363-9762","type":"print"}],"subject":[],"published":{"date-parts":[[2019,8,22]]}}}