{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T12:37:23Z","timestamp":1784205443780,"version":"3.55.0"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Nucl Med"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>The aim of this study was to assess the value of intravenously contrast-enhanced CT in conjunction with <jats:sup>99m<\/jats:sup>Tc-MIBI SPECT for preoperative localization of parathyroid adenoma.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>One hundred ninety-two patients with primary hyperparathyroidism were enrolled in the study between May 2015 and May 2017. The patients underwent a preoperative \u201cone-stop shop\u201d examination with <jats:sup>99m<\/jats:sup>Tc-MIBI SPECT\/CT by using dual time-point (10 and 90 minutes) protocol and both nonenhanced CT and contrast-enhanced CT acquisition in the arterial and venous phase, 35 and 75 seconds, respectively, after contrast medium injection start. For 149 patients, the imaging results could be correlated to those at surgery and histopathology.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The median adenoma weight was 330 mg. The addition of contrast-enhanced CT increased the sensitivity from 81.1% to 89.9% (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.003). The specificity of nonenhanced SPECT\/CT was similar to contrast-enhanced CT (96.1% vs 97.9%; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.077). For patients with uniglandular disease (n = 140, 94.0%), the sensitivity increased from 86.4% to 93.6% (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.021) and the specificity from 96.2% to 97.9% (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.118) by adding contrast-enhanced CT. In patients with multiglandular disease (n = 9, 6.0%), adding contrast-enhanced CT improved detection sensitivity from 42.1% to 63.2%. However, these patients were few and significance was not reached (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.125).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>In this cohort, with generally small parathyroid adenomas, the sensitivity in preoperative localization was greatly improved by adding contrast-enhanced CT to <jats:sup>99m<\/jats:sup>Tc-MIBI SPECT\/CT.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rlu.0000000000002778","type":"journal-article","created":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T19:20:08Z","timestamp":1572895208000},"page":"929-935","source":"Crossref","is-referenced-by-count":17,"title":["Multiphase Iodine Contrast-Enhanced SPECT\/CT Outperforms Nonenhanced SPECT\/CT for Preoperative Localization of Small Parathyroid Adenomas"],"prefix":"10.1097","volume":"44","author":[{"given":"Patricia","family":"Sandqvist","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inga-Lena","family":"Nilsson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Per","family":"Gryb\u00e4ck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alejandro","family":"Sanchez-Crespo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anders","family":"Sundin","sequence":"additional","affiliation":[{"name":"Department of Radiology, Section for Molecular Imaging, Institution for Surgical Sciences, Uppsala University Hospital, Uppsala, Sweden."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,10,31]]},"reference":[{"key":"bib1-20230925","doi-asserted-by":"crossref","first-page":"353","DOI":"10.3109\/00016925409175876","article-title":"Localization of parathyroid adenomata by arteriography","volume":"42","year":"1954","journal-title":"Acta Radiol"},{"key":"bib2-20230925","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.ejrad.2017.01.004","article-title":"Diagnostic performance of computed tomography for parathyroid adenoma localization; a systematic review and meta-analysis","volume":"88","year":"2017","journal-title":"Eur J Radiol"},{"key":"bib3-20230925","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1177\/0194599814562195","article-title":"Comparison of 4D CT, ultrasonography, and 99mTc sestamibi SPECT\/CT in localizing single-gland primary hyperparathyroidism","volume":"152","year":"2015","journal-title":"Otolaryngol Head Neck Surg"},{"key":"bib4-20230925","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1111\/ans.12571","article-title":"Four-dimensional computed tomography for parathyroid localization: a new imaging modality","volume":"85","year":"2015","journal-title":"ANZ J Surg"},{"key":"bib5-20230925","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1007\/s00423-009-0545-1","article-title":"CT-MIBI-SPECT image fusion predicts multiglandular disease in hyperparathyroidism","volume":"395","year":"2010","journal-title":"Langenbecks Arch Surg"},{"key":"bib6-20230925","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1007\/s00423-008-0359-6","article-title":"Virtual neck exploration in patients with hyperparathyroidism and former cervical operations","volume":"393","year":"2008","journal-title":"Langenbecks Arch Surg"},{"key":"bib7-20230925","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/S0039-6060(03)00396-9","article-title":"CT-MIBI image fusion: a new preoperative localization technique for primary, recurrent, and persistent hyperparathyroidism","volume":"135","year":"2004","journal-title":"Surgery"},{"key":"bib8-20230925","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1002\/lary.25020","article-title":"Accuracy of early-phase versus dual-phase single-photon emission computed tomography\/computed tomography in the localization of parathyroid disease","volume":"125","year":"2015","journal-title":"Laryngoscope"},{"key":"bib9-20230925","article-title":"Contrast-enhanced computed tomography does not improve the diagnostic value of parathyroid dual-phase MIBI SPECT\/CT","year":"2018","journal-title":"Nucl Med Commun"},{"issue":"Suppl 1","key":"bib10-20230925","first-page":"E2159","article-title":"Detection rate of (99m) Tc-MIBI single photon emission computed tomography (SPECT)\/CT in preoperative planning for patients with primary hyperparathyroidism: a meta-analysis","volume":"38","year":"2016","journal-title":"Head Neck"},{"key":"bib11-20230925","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/MNM.0000000000000262","article-title":"Parathyroid adenoma localization with 99mTc-sestamibi SPECT\/CT: a meta-analysis","volume":"36","year":"2015","journal-title":"Nucl Med Commun"},{"key":"bib12-20230925","first-page":"127","article-title":"Comparison of SPET\/CT, SPET and planar imaging using 99mTc-MIBI as independent techniques to support minimally invasive parathyroidectomy in primary hyperparathyroidism: a meta-analysis","volume":"18","year":"2015","journal-title":"Hell J Nucl Med"},{"key":"bib13-20230925","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1097\/RLU.0000000000001115","article-title":"Influence of multigland parathyroid disease on 99mTc-sestamibi SPECT\/CT","volume":"41","year":"2016","journal-title":"Clin Nucl Med"},{"key":"bib14-20230925","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/MNM.0000000000000216","article-title":"A comparison between 11C-methionine PET\/CT and MIBI SPECT\/CT for localization of parathyroid adenomas\/hyperplasia","volume":"36","year":"2015","journal-title":"Nucl Med Commun"},{"key":"bib15-20230925","doi-asserted-by":"crossref","first-page":"2012","DOI":"10.2967\/jnumed.108.054858","article-title":"Preoperative 123I\/99mTc-sestamibi subtraction SPECT and SPECT\/CT in primary hyperparathyroidism","volume":"49","year":"2008","journal-title":"J Nucl Med"},{"key":"bib16-20230925","doi-asserted-by":"crossref","first-page":"e109","DOI":"10.1097\/RLU.0000000000001447","article-title":"SPECT\/CT's advantage for preoperative localization of small parathyroid adenomas in primary hyperparathyroidism","volume":"42","year":"2017","journal-title":"Clin Nucl Med"},{"key":"bib17-20230925","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.surg.2006.07.028","article-title":"Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography","volume":"140","year":"2006","journal-title":"Surgery"},{"key":"bib18-20230925","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/j.surg.2016.04.016","article-title":"Clinical efficacy of 2-phase versus 4-phase computed tomography for localization in primary hyperparathyroidism","volume":"160","year":"2016","journal-title":"Surgery"},{"key":"bib19-20230925","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.ijsu.2015.01.005","article-title":"Two-phase (low-dose) computed tomography is as effective as 4D-CT for identifying enlarged parathyroid glands","volume":"14","year":"2015","journal-title":"Int J Surg"},{"key":"bib20-20230925","doi-asserted-by":"crossref","first-page":"e3586","DOI":"10.7717\/peerj.3586","article-title":"Single phase computed tomography is equivalent to dual phase method for localizing hyperfunctioning parathyroid glands in patients with primary hyperparathyroidism: a retrospective review","volume":"5","year":"2017","journal-title":"PeerJ"},{"key":"bib21-20230925","doi-asserted-by":"crossref","first-page":"1959","DOI":"10.3174\/ajnr.A3978","article-title":"Dynamic CT for parathyroid disease: are multiple phases necessary?","volume":"35","year":"2014","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["Clinical Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLU.0000000000002778","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,25]],"date-time":"2023-09-25T05:00:35Z","timestamp":1695618035000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLU.0000000000002778"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,31]]},"references-count":21,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/rlu.0000000000002778","relation":{},"ISSN":["1536-0229","0363-9762"],"issn-type":[{"value":"1536-0229","type":"electronic"},{"value":"0363-9762","type":"print"}],"subject":[],"published":{"date-parts":[[2019,10,31]]}}}