{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T15:09:24Z","timestamp":1784560164513,"version":"3.55.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Clin Nucl Med"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>The aim of this study was to evaluate if integrating whole-body PET\/CT with CT colonography (PET\/CTC) improves the preoperative diagnosis of obstructive colorectal cancer (CRC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      We prospectively included 47 consecutive patients (18 women and 29 men; mean age, 71 \u00b1 14 years) suspected of having CRC by optical colonoscopy, which was not completed due to obstructive masses. To perform PET\/CTC, a small caliber Foley catheter was inserted to distend the colon with CO\n                      <jats:sub>2<\/jats:sub>\n                      insufflations. Polyps measuring 10 mm or larger were considered as high risk of malignancy. All findings were histologically confirmed.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Colorectal cancer was localized in the sigmoid (n = 21), rectum (n = 7), rectosigmoid junction (n = 5), ascending (n = 7), descending (n = 5), and transverse (n = 2) colon. All tumors showed FDG uptake (mean \u00b1 SD SUV\n                      <jats:sub>max<\/jats:sub>\n                      , 20.02 \u00b1 9.9) including one synchronic tumor (SUV\n                      <jats:sub>max<\/jats:sub>\n                      , 10.46). Forty-seven polyps were histologically confirmed as smaller than 10 mm (n = 35) and 10 mm or larger (n = 12). All 12 polyps 10 mm or larger showed FDG uptake (SUV\n                      <jats:sub>max<\/jats:sub>\n                      range, 3.08\u201319.5), but only one smaller than 10 mm could be identified by PET. Pathological lymph nodes were diagnosed in 17\/47 cases after surgical removal with a sensitivity and specificity for CTC and PET\/CTC of 71% and 97% and 59% and 100%, respectively. Liver metastases were confirmed in 9 patients and in 4\/9 along with lung metastases (n = 2) or implants (n = 2), showing a sensitivity and specificity for CTC of 89% and 100% and both 100% for PET\/CTC.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>PET\/CTC is a reliable technique for staging CRC and diagnosing synchronous tumors. In this series, PET\/CTC was not able to identify small polyps but showed potential use for ruling out 10 mm or larger polyps at high risk of malignancy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/rlu.0000000000003252","type":"journal-article","created":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T17:24:59Z","timestamp":1601486699000},"page":"943-947","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["PET\/CT Integrated With CT Colonography in Preoperative Obstructive Colorectal Cancer by Incomplete Optical Colonoscopy"],"prefix":"10.1097","volume":"45","author":[{"given":"Nuria","family":"S\u00e1nchez-Izquierdo","sequence":"first","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Pag\u00e8s","sequence":"additional","affiliation":[{"name":"Radiology, Hospital Cl\u00ednic de Barcelona, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Mayoral","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domenico","family":"Rubello","sequence":"additional","affiliation":[{"name":"Nuclear Medicine Unit, Santa Maria della Misericordia Hospital, Rovigo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick M.","family":"Colletti","sequence":"additional","affiliation":[{"name":"Department of Radiology, Keck School of Medicine of USC, Los Angeles, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Campos","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inmaculada","family":"Romero","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebasti\u00e1n","family":"Casanueva","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Fritsch","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Fuster","sequence":"additional","affiliation":[{"name":"Nuclear Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,9,9]]},"reference":[{"key":"bib1-20260120","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1002\/bjs.1800741021","article-title":"Synchronous and early metachronous carcinomas of the colon and rectum","volume":"74","year":"1987","journal-title":"Br J Surg"},{"key":"bib2-20260120","doi-asserted-by":"crossref","first-page":"25","DOI":"10.4103\/1450-1147.150524","article-title":"Focal colonic FDG activity with PET\/CT: guidelines for recommendation of colonoscopy","volume":"14","year":"2015","journal-title":"World J Nucl Med"},{"key":"bib3-20260120","doi-asserted-by":"crossref","first-page":"373","DOI":"10.7326\/0003-4819-113-5-373","article-title":"Screening for colorectal cancer","volume":"113","year":"1990","journal-title":"Ann Intern Med"},{"key":"bib4-20260120","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/S0016-5107(92)70516-1","article-title":"Accuracy of assessment of the extent of examination by experienced colonoscopists","volume":"38","year":"1992","journal-title":"Gastrointest Endosc"},{"key":"bib5-20260120","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1055\/s-0030-1255523","article-title":"Colonic work-up after incomplete colonoscopy: significant new findings during follow-up","volume":"42","year":"2010","journal-title":"Endoscopy"},{"key":"bib6-20260120","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1055\/s-0032-1306690","article-title":"Clinical practice guidelines: quality of colonoscopy in colorectal cancer screening","volume":"44","year":"2012","journal-title":"Endoscopy"},{"key":"bib7-20260120","doi-asserted-by":"crossref","first-page":"2191","DOI":"10.1056\/NEJMoa031618","article-title":"Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults","volume":"349","year":"2003","journal-title":"N Engl J Med"},{"key":"bib8-20260120","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1056\/NEJMoa0800996","article-title":"Accuracy of CT colonography for detection of large adenomas and cancers","volume":"359","year":"2008","journal-title":"N Engl J Med"},{"key":"bib9-20260120","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.gie.2011.03.1257","article-title":"EUS and magnetic resonance imaging in the staging of rectal cancer: a prospective and comparative study","volume":"74","year":"2011","journal-title":"Gastrointest Endosc"},{"key":"bib10-20260120","doi-asserted-by":"crossref","first-page":"3199","DOI":"10.1001\/jama.290.24.3199","article-title":"Whole-body dual-modality PET\/CT and whole-body MRI for tumor staging in oncology","volume":"290","year":"2003","journal-title":"JAMA"},{"key":"bib11-20260120","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1148\/radiology.206.3.9494497","article-title":"Staging of primary colorectal carcinomas with fluorine-18 fluorodeoxyglucose whole-body PET: correlation with histopathologic and CT findings","volume":"206","year":"1998","journal-title":"Radiology"},{"key":"bib12-20260120","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1136\/gut.2005.064170","article-title":"Whole body positron emission tomography computed tomography (PET\/CT) tumour staging with integrated PET\/CT colonography: technical feasibility and first experiences in patients with colorectal cancer","volume":"55","year":"2006","journal-title":"Gut"},{"key":"bib13-20260120","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.1007\/s00259-007-0422-5","article-title":"PET\/CT colonography in patients with colorectal polyps: a feasibility study","volume":"34","year":"2007","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"bib14-20260120","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1007\/s00261-007-9202-8","article-title":"Whole-body PET\/CT-colonography: a possible new concept for colorectal cancer staging","volume":"32","year":"2007","journal-title":"Abdom Imaging"},{"key":"bib15-20260120","doi-asserted-by":"crossref","first-page":"854","DOI":"10.2967\/jnumed.109.072728","article-title":"Nonlaxative PET\/CT colonography: feasibility, acceptability, and pilot performance in patients at higher risk of colonic neoplasia","volume":"51","year":"2010","journal-title":"J Nucl Med"},{"key":"bib16-20260120","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1007\/s10350-008-9236-1","article-title":"PET\/CT colonography for the preoperative evaluation of the colon proximal to the obstructive colorectal cancer","volume":"51","year":"2008","journal-title":"Dis Colon Rectum"},{"key":"bib17-20260120","first-page":"246","article-title":"Update on PET\/CT colonography in the diagnosis of colorectal cancer","volume":"35","year":"2016","journal-title":"Rev Esp Med Nucl Imagen Mol"},{"key":"bib18-20260120","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1007\/s00330-012-2632-x","article-title":"The second ESGAR consensus statement on CT colonography","volume":"23","year":"2013","journal-title":"Eur Radiol"},{"key":"bib19-20260120","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1016\/j.jacr.2009.09.007","article-title":"ACR Colon Cancer Committee white paper: status of CT colonography 2009","volume":"6","year":"2009","journal-title":"J Am Coll Radiol"},{"key":"bib20-20260120","doi-asserted-by":"crossref","first-page":"130","DOI":"10.2214\/AJR.05.1458","article-title":"Combined CT colonography and 18F-FDG PET of colon polyps: potential technique for selective detection of cancer and precancerous lesions","volume":"188","year":"2007","journal-title":"Am J Roentgenol"},{"key":"bib21-20260120","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1111\/jgh.13486","article-title":"Fluoro-2-deoxy-d-glucose positron emission tomography\/computed tomography for the detection of proximal synchronous lesions in patients with obstructive colorectal cancer","volume":"32","year":"2017","journal-title":"J Gastroenterol Hepatol"},{"key":"bib22-20260120","doi-asserted-by":"crossref","first-page":"853","DOI":"10.3748\/wjg.14.853","article-title":"Colonography by CT, MRI and PET\/CT combined with conventional colonoscopy in colorectal cancer screening and staging","volume":"14","year":"2008","journal-title":"World J Gastroenterol"},{"key":"bib23-20260120","doi-asserted-by":"crossref","first-page":"940","DOI":"10.2214\/AJR.06.0764","article-title":"Characteristics of advanced adenomas detected at CT colonographic screening, implications for appropriate polyp size thresholds for polypectomy versus surveillance","volume":"188","year":"2007","journal-title":"Am J Roentgenol"},{"key":"bib24-20260120","first-page":"1784","article-title":"Routine (18)F-FDG PET preoperative staging of colorectal cancer: comparison with conventional staging and its impact on treatment decision making","volume":"44","year":"2003","journal-title":"J Nucl Med"},{"key":"bib25-20260120","doi-asserted-by":"crossref","first-page":"2590","DOI":"10.1001\/jama.296.21.2590","article-title":"Diagnostic accuracy of colorectal cancer staging with whole-body PET\/CT colonography","volume":"296","year":"2006","journal-title":"JAMA"},{"key":"bib26-20260120","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1080\/02841850701294560","article-title":"Contrast-enhanced FDG-PET\/CT vs. SPIO-enhanced MRI vs. FDG-PET vs. CT in patients with liver metastases from colorectal cancer: a prospective study with intraoperative confirmation","volume":"48","year":"2007","journal-title":"Acta Radiol"}],"container-title":["Clinical Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLU.0000000000003252","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T22:00:19Z","timestamp":1768946419000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLU.0000000000003252"}},"subtitle":["A Prospective Study"],"short-title":[],"issued":{"date-parts":[[2020,9,9]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/rlu.0000000000003252","relation":{},"ISSN":["1536-0229","0363-9762"],"issn-type":[{"value":"1536-0229","type":"electronic"},{"value":"0363-9762","type":"print"}],"subject":[],"published":{"date-parts":[[2020,9,9]]}}}