{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T17:25:26Z","timestamp":1757611526919,"version":"3.44.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>AI-driven scan time reduction is rapidly transforming medical imaging with benefits such as improved patient comfort and enhanced efficiency. A Dual Contrastive Learning Generative Adversarial Network (DCLGAN) was developed to predict full-time PET scans from shorter, noisier scans, improving challenges in imaging patients with movement disorders.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients and Methods:<\/jats:title>\n            <jats:p>\n                                 <jats:sup>18<\/jats:sup>F FP-CIT PET\/CT data from 391 patients with suspected Parkinsonism were used [250 training\/validation, 141 testing (hospital A)]. Ground truth (GT) images were reconstructed from 15-minute scans, while denoised images (DIs) were generated from 1-, 3-, 5-, and 10-minute scans. Image quality was assessed using normalized root mean square error (NRMSE), peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), visual analysis, and clinical metrics like BP<jats:sub>ND<\/jats:sub> and ISR for diagnosis of non-neurodegenerative Parkinson disease (NPD), idiopathic PD (IPD), and atypical PD (APD). External validation used data from 2 hospitals with different scanners (hospital B: 1-, 3-, 5-, and 10-min; hospital C: 1-, 3-, and 5-min). In addition, motion artifact reduction was evaluated using the Dice similarity coefficient (DSC).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In hospital A, NRMSE, PSNR, and SSIM values improved with scan duration, with the 5-minute DIs achieving optimal quality (NRMSE 0.008, PSNR 42.13, SSIM 0.98). Visual analysis rated DIs from scans \u22653 minutes as adequate or higher. The mean BP<jats:sub>ND<\/jats:sub> differences (95% CI) for each DIs were 0.19 (\u22120.01, 0.40), 0.11 (\u22120.02, 0.24), 0.08 (\u22120.03, 0.18), and 0.01 (\u22120.06, 0.07), with the CIs significantly decreasing. ISRs with the highest effect sizes for differentiating NPD, IPD, and APD (PP\/AP, PP\/VS, PC\/VP) remained stable post-denoising. External validation showed 10-minute DIs (hospital B) and 1-minute DIs (hospital C) reached benchmarks of hospital A\u2019s image quality metrics, with similar trends in visual analysis and BP<jats:sub>ND<\/jats:sub> CIs. Furthermore, motion artifact correction in 9 patients yielded DSC improvements from 0.89 to 0.95 in striatal regions.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The DL-model is capable of generating high-quality <jats:sup>18<\/jats:sup>F FP-CIT PET images from shorter scans to enhance patient comfort, minimize motion artifacts, and maintain diagnostic precision. Furthermore, our study plays an important role in providing insights into how imaging quality assessment metrics can be used to determine the appropriate scan duration for different scanners with varying sensitivities.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rlu.0000000000006040","type":"journal-article","created":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T05:00:10Z","timestamp":1751346010000},"page":"e580-e588","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["GAN-based Denoising for Scan Time Reduction and Motion Correction of 18F FP-CIT PET\/CT: A Multicenter External Validation Study"],"prefix":"10.1097","volume":"50","author":[{"given":"Hyunkyung","family":"Han","sequence":"first","affiliation":[{"name":"Artificial Intelligence"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2856-402X","authenticated-orcid":false,"given":"Kyobin","family":"Choo","sequence":"additional","affiliation":[{"name":"Computer Science, Yonsei University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tae Joo","family":"Jeon","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Yonsei University College of Medicine"},{"name":"Department of Nuclear Medicine, Gangnam Severance Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sangwon","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Yonsei University College of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seungbeom","family":"Seo","sequence":"additional","affiliation":[{"name":"Yonsei University College of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dongwoo","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Seoul"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sun Jung","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, National Health Insurance Service Hospital, Gyeonggi-do"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4580-3918","authenticated-orcid":false,"given":"Suk Hyun","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Nuclear Medicine, Hallym University Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mijin","family":"Yun","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Yonsei University College of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,7,1]]},"reference":[{"key":"R1-20250903","doi-asserted-by":"crossref","first-page":"399","DOI":"10.2967\/jnumed.111.095224","article-title":"Subregional patterns of preferential striatal dopamine transporter loss differ in Parkinson disease, progressive supranuclear palsy, and multiple-system atrophy","volume":"53","author":"Oh","year":"2012","journal-title":"J Nucl Med"},{"key":"R2-20250903","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s13139-024-00840-x","article-title":"Imaging procedure and clinical studies of [18F]FP-CIT PET","volume":"58","author":"Sung","year":"2024","journal-title":"Nucl Med Mol Imaging"},{"key":"R3-20250903","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1002\/1531-8257(200011)15:6<1158::AID-MDS1015>3.0.CO;2-0","article-title":"[123I] \u03b2-CIT SPECT in multiple system atrophy, progressive supranuclear palsy, and corticobasal degeneration","volume":"15","author":"Pirker","year":"2000","journal-title":"Mov Disord"},{"key":"R4-20250903","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1002\/mds.1256","article-title":"[123I] \u03b2-CIT SPECT imaging demonstrates reduced density of striatal dopamine transporters in Parkinson\u2019s disease and multiple system atrophy","volume":"16","author":"Varrone","year":"2001","journal-title":"Mov Disord"},{"key":"R5-20250903","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1007\/s13139-012-0182-4","article-title":"Differential diagnosis of parkinsonism using dual-phase F-18 FP-CIT PET imaging","volume":"47","author":"Jin","year":"2013","journal-title":"Nucl Med Mol Imaging"},{"key":"R6-20250903","doi-asserted-by":"crossref","first-page":"e22409","DOI":"10.1016\/j.heliyon.2023.e22409","article-title":"ChatGPT-assisted deep learning for diagnosing bone metastasis in bone scans: bridging the AI gap for clinicians","volume":"9","author":"Son","year":"2023","journal-title":"Heliyon"},{"key":"R7-20250903","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s13139-021-00733-3","article-title":"Preparing for the artificial intelligence revolution in nuclear cardiology","volume":"57","author":"Garcia","year":"2023","journal-title":"Nucl Med Mol Imaging"},{"key":"R8-20250903","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1007\/s13139-023-00802-9","article-title":"Deep learning-based feature extraction from whole-body PET\/CT employing maximum intensity projection images: preliminary results of lung cancer data","volume":"57","author":"Gil","year":"2023","journal-title":"Nucl Med Mol Imaging"},{"key":"R9-20250903","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1007\/s13139-022-00745-7","article-title":"Automatic lung cancer segmentation in [18F] FDG PET\/CT using a two-stage deep learning approach","volume":"57","author":"Park","year":"2023","journal-title":"Nucl Med Mol Imaging"},{"key":"R10-20250903","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1007\/s13139-022-00765-3","article-title":"Artificial intelligence increases the agreement among physicians classifying focal skeleton\/bone marrow uptake in hodgkin\u2019s lymphoma patients staged with [18f] fdg pet\/ct\u2014a retrospective study","volume":"57","author":"Sadik","year":"2023","journal-title":"Nucl Med Mol Imaging"},{"key":"R11-20250903","doi-asserted-by":"crossref","first-page":"102787","DOI":"10.1016\/j.media.2023.102787","article-title":"AIGAN: Attention\u2013encoding Integrated Generative Adversarial Network for the reconstruction of low-dose CT and low-dose PET images","volume":"86","author":"Fu","year":"2023","journal-title":"Med Image Anal"},{"key":"R12-20250903","first-page":"213","article-title":"Parameter-transferred Wasserstein generative adversarial network (PT-WGAN) for low-dose PET image denoising","volume":"5","author":"Gong","year":"2020","journal-title":"IEEE TRPMS"},{"key":"R13-20250903","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/s13139-024-00845-6","article-title":"A review of machine learning approaches for brain positron emission tomography data analysis","volume":"58","author":"Xu","year":"2024","journal-title":"Nucl Med Mol Imaging"},{"key":"R14-20250903","doi-asserted-by":"crossref","first-page":"e133","DOI":"10.1097\/RLU.0000000000003471","article-title":"PET\/CT for brain amyloid: a feasibility study for scan time reduction by deep learning","volume":"46","author":"Lee","year":"2021","journal-title":"Clin Nucl Med"},{"key":"R15-20250903","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1136\/jnnp.55.3.181","article-title":"Accuracy of clinical diagnosis of idiopathic Parkinson\u2019s disease: a clinico-pathological study of 100 cases","volume":"55","author":"Hughes","year":"1992","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"R16-20250903","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1109\/CVPRW53098.2021.00084","article-title":"Dual contrastive learning for unsupervised image-to-image translation","author":"Han","year":"2021","journal-title":"2021 IEEE\/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW)"},{"key":"R18-20250903","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/j.neuroimage.2006.09.022","article-title":"Automated template-based PET region of interest analyses in the aging brain","volume":"34","author":"Sun","year":"2007","journal-title":"Neuroimage"},{"key":"R19-20250903","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1007\/s13139-020-00669-0","article-title":"Spatial normalization using early-phase [18 F] FP-CIT PET for quantification of striatal dopamine transporter binding","volume":"54","author":"Bae","year":"2020","journal-title":"Nucl Med Mol Imaging"},{"key":"R20-20250903","doi-asserted-by":"crossref","first-page":"e463","DOI":"10.1097\/RLU.0000000000003281","article-title":"Clinical and striatal dopamine transporter predictors of mild behavioral impairment in drug-naive Parkinson disease","volume":"45","author":"Yoo","year":"2020","journal-title":"Clin Nucl Med"},{"key":"R22-20250903","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1007\/s13139-020-00667-2","article-title":"Self-supervised PET denoising","volume":"54","author":"Yie","year":"2020","journal-title":"Nucl Med Mol Imaging"},{"key":"R23-20250903","doi-asserted-by":"crossref","first-page":"104919","DOI":"10.1016\/j.compbiomed.2021.104919","article-title":"Feasibility evaluation of PET scan-time reduction for diagnosing amyloid-\u03b2 levels in Alzheimer\u2019s disease patients using a deep-learning-based denoising algorithm","volume":"138","author":"Peng","year":"2021","journal-title":"Comput Biol Med"},{"key":"R24-20250903","doi-asserted-by":"crossref","first-page":"119412","DOI":"10.1016\/j.neuroimage.2022.119412","article-title":"Deep learning based low-activity PET reconstruction of [11C] PiB and [18F] FE-PE2I in neurodegenerative disorders","volume":"259","author":"Daveau","year":"2022","journal-title":"Neuroimage"},{"key":"R25-20250903","doi-asserted-by":"crossref","first-page":"210","DOI":"10.2967\/jnumed.109.063701","article-title":"Movement correction method for human brain PET images: application to quantitative analysis of dynamic 18F-FDDNP scans","volume":"51","author":"Wardak","year":"2010","journal-title":"J Nucl Med"},{"key":"R26-20250903","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1186\/s40658-024-00653-z","article-title":"Improving diagnostic precision in amyloid brain PET imaging through data-driven motion correction","volume":"11","author":"Park","year":"2024","journal-title":"EJNMMI Phys"}],"container-title":["Clinical Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RLU.0000000000006040","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,3]],"date-time":"2025-09-03T21:00:41Z","timestamp":1756933241000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RLU.0000000000006040"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,1]]},"references-count":24,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/rlu.0000000000006040","relation":{},"ISSN":["0363-9762","1536-0229"],"issn-type":[{"type":"print","value":"0363-9762"},{"type":"electronic","value":"1536-0229"}],"subject":[],"published":{"date-parts":[[2025,7,1]]},"assertion":[{"value":"2025-03-27","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}